Page 2
Operators Manual Installation, Operation & Service Direct Steam Table Top Kettles Table-Top Direct Steam Kettles MODELS: KDT- 1 - T KDT- 3 - T KDT- 6 - T KDT-12 - T KDT-20 - T SD Stands MODELS: SD - 450 SD - 650 SD - 760 SD -1050...
Page 3
For your safety DANGER Keep clear of pressure Keep hands away from relief discharge. moving parts and pinch points. IMPORTANT Do not fill kettle above Inspect unit daily for recommended level proper operation. marked on outside of kettle. CAUTION Surfaces may be Wear protective equipment extremely hot! Use when discharging hot product.
INSTALLATION GENERAL Note: For SD Stands (with or without kettles) zero clearance is required on the sides and back. Installation of the unit must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper KETTLES installation of product could cause injury or damage.
Page 5
STEAM CONDENSATE (Kettles c/w SD Stands) The stand comes factory plumbed so the condensate All steam plumbing to and from the kettle and is connected to the stands drain manifold. steam boiler should be thoroughly cleaned and inspected for dirt and debris before final POTABLE WATER connection to the kettle are made.
OPERATING INSTRUCTIONS CLEVELAND STEAM COOKING EQUIPMENT IS INTENDED FOR COMMERCIAL USE ONLY BY PROFESSIONALLY TRAINED PERSONNEL. OPERATION FOR KETTLE/STEAMER COMBINATIONS: 1. Ensure that there is an adequate steam If the boiler in a steamer is supplying steam to a supply to the kettle. kettle, always heat the kettle first.
CLEANING INSTRUCTIONS CLEANING INSTRUCTIONS CAUTION 1. Turn unit off. SURFACES MAY 2. Remove drain screen (if applicable). Thoroughly BE EXTREMELY HOT! wash and rinse the screen either in a sink or a dishwasher. CARE AND CLEANING 3. Prepare a warm water and mild detergent solution in the unit.
STAINLESS STEEL EQUIPMENT CARE AND CLEANING (Suppied courtesy of Nafem. For more information visit their web site at www.nafem.org) Contrary to popular belief, stainless steels ARE susceptible to rusting. 4. Treat your water. Corrosion on metals is everywhere. It is recognized quickly on iron and Though this is not always practical, softening hard water can do much steel as unsightly yellow/orange rust.
Page 10
STEAM CONTROL ASSEMBLY ITEM NO. PART NO. DESCRIPTION QTY. FA11056 Binding Head Screw, 6-32 x 1/2" lg........4 KE50458 End Cap, condensate return .
PLUMBING ASSEMBLY (for SD Stands) See Steam Control Drawing See Steam Control Drawing STEAM STEAM CONDENSATE CONDENSATE RETURN RETURN See Steam Control Drawing Steam In Configuration for SD Stand with Two Kettles STEAM STEAM...
MAINTENANCE ALL SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN. This kettle requires very little preventative maintenance other than daily cleaning. The pressure relief valve must be tested twice a year. PRESSURE RELIEF VALVE MARINE LOCK TESTING PROCEDURE Inspect lock at least twice yearly. 1.
TROUBLESHOOTING GUIDE This section contains information intended for use by Authorized Service Personnel only. PROBLEM A/ Kettle heats too slowly or does not come to a boil. Probable Cause Remedy 1. Inadequate steam flow. Check for correct steam using chart below. If kettle is connected to a steamer and powered by a generator the units should be operated sequentially (kettle boiling first, then start steamer).