Panasonic CS/CU-KU12ZKY Series Operating & Installation Instructions Manual page 29

Table of Contents

Advertisement

BEE Regulation
Testing Guidelines
Cooling Capacity Test Method
Turn on the main power supply to unit.
1) Mode
2) Temperature
3) Air Swing
Vertical Airflow
4) Fan speed
Heating Capacity Test Method
Turn on the main power supply to unit.
1) Mode
2) Temperature
3) Air Swing
Vertical Airflow
4) Fan speed
• Open the Front Panel by lifting Intake Grille.
• Follow the below Instructions.
Step a): Press and Hold the button on indoor unit.
Step b): Within 5 second, press once the Remote Control
unit button.
Step c): After hearing a beep sound from the Indoor Unit, immediately release the Auto ON/OFF
button on Indoor Unit.
All this should be done within 5 seconds.
Indoor unit Temperature Display will show "
(Indication for Full load)
* This test guideline is applicable for "KZ" models only
(For HOT & COLD Models)
: Select 'COOL'
: a) Set Temp. 16 ºC for Full
Load (100%)
: b) Set Temp. 17 ºC for Half
Load (50%)
: Set vane position to 3rd step
from top
: Maximum
: Select 'HEAT'
: a) Set Temp. 30 ºC for Full
Load (100%)
: b) Set Temp. 29 ºC for Half
Load (50%)
: Set vane position to 3rd step
from top
: Maximum
(Indication for Half load)
(For COOL Mode)
1
2
1
2
FULL LOAD
(For HEAT Mode)
HEAT
1
2
1
2
FULL LOAD
button while holding the indoor
" for Full Load and "
QUIET
CLEAN
1
2
1
2
HALF LOAD
HEAT
QUIET
CLEAN
1
2
1
2
HALF LOAD
" for Half Load Setting.