Safe operaration is possible provided that
the underpressure in the room where the
burner is installed does not exceed 4 Pa
(0,04 mbar).
This can be achieved if combustion air can
flow through non- lockable openings, e.g.
in doors, windows and via the air-
intake/exhaust air wall box, or by the other
technical measures, such as reciprocal
interlocking. Etc...
If the air intake is inadequate there is a
risk of poisoning from combustion
gases which are drawn back into the
room.
An air-intake/exhaust air wall box by itself
is no guarantee that the limiting value will
not be exceeded.
Note: when assessing the overall
requirement, the combined ventilation
system for the entire household must be
taken into considertion. This rule does not
apply to the use of cooking appliances,
such as hobs and ovens.
If the exhaust air is going to be
discharged into the open, a telescopic
wall box should be fitted into the
outside wall.

Operating procedure

To activate the functions simply tap
the buttons. If the buttons are pressed for
too long, no function is activated.
The most effective method of
removing vapours produced during
cooking is to:
Switch the ventilator ON
as soon as you begin cooking.
Switch the ventilator OFF
a few minutes after you have finished
cooking.
Light
Speeds
Indicator
It switches
It decreases the
motor off
speeds
Acoustic signal
When a push button is pressed, this is
verified by an acoustic signal.
Switching the fan ON
Press the + Push button
Setting the required fan speed
Press the + Push button
The fan speed is increased by one
step.
Press the - Push button
The fan speed is reduced by one
step.
Switching the fan OFF
Press the O Push button
the displayed
afterwards.
Or
Keep pressed the – push button until
the fan switches off.
The displayed
afterwards.
Intensive Setting:
Maximum power is obtained at the
intensive setting. It is only required for
short intervals.
Keep pressed the + button until a
appears in the display.
If the intensive setting is not cancelled
by hand, the fan will automatically
switch back to step
minutes.
Fan follow on:
Press the
. button
The fan continues to run at step
10 minutes and at the same time a
Timer
It switches motor on
and increases the
speeds
goes out shortly
goes out shortly
after 10
for
15