OPERATION

Initial Start Up
After satisfying the installation requirements, the unit is ready to start. The unit will start when the power cord is connected to the
required power source. If the compressor does not start when the unit is initially plugged in, check to make sure that the
temperature control is not in the 'off ' position. Allow the unit to run a minimum of two hours before loading it with product.
Temperature Control
The Temperature Control is located on the compressor end of the unit. To obtain colder temperatures turn the Temperature Control
knob clockwise and visa versa. Allow the unit a minimum of two hours to respond to a control setting adjustment.
Defrost
Your Silver King unit is a manual defrost unit. It should be defrosted whenever the walls accumulate a frost layer that is ¼ inch
thick. To defrost the unit, either turn the Temperature Control stem to the "off" position (fully counterclockwise) or disconnect the
power from the electrical receptacle and remove the pans. After the frost has melted or come loose from the walls, wipe out the
cabinet interior. Do not attempt to scrape or chisel off the frost as you could do irreparable damage to the unit.

MAINTENANCE

Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of
the appliance.
Cabinet Surfaces
The cabinet interior is aluminum and the exterior is stainless steel. These surfaces should be cleaned periodically with a solution of
warm water and mild soap, rinsed with clean water and wiped dry with a soft cloth. A stainless steel cleaner can also be used.
Should a surface become stained, do not attempt to clean with an abrasive cleaner or scouring pad. Use a soft cleanser and rub
with the grain of the metal to avoid scratching the surface. Do not use chlorinated cleaners.
Pumps
To maintain the operation of the Pumps they should be disassembled and cleaned inside and out regularly. To do so, first remove
the Pump from the Jar and immerse it in hot soapy water while operating the pump to purge the product that is inside of it. Repeat
with clean water once the inside of the pump has been thoroughly purged. To disassemble the pump, refer to the parts list supplied
for a complete breakdown of the Pumps.
Condenser
Periodically, accumulated dust must be removed from the condenser. First, disconnect the unit from the power supply. To clear the
dust, blow air though the condenser fins or remove the end panel and brush the dust from the backside of the condenser.