Cooling
<Capacity>
150%
Indoor:80/65
140%
130%
120%
110%
100%
90%
80%
70%
60%
14
Outdoor DB( F)
<Input>
120%
Indoor:80/65
110%
100%
90%
80%
70%
60%
50%
40%
30%
20%
14
Outdoor DB( F)
Both capacity and input decrease when temperature is 66 or less degrees F, for compressor
*
frequency restrictions operate.
Both capacity and input decrease when temperature is 104 or more degrees F, as compressor speed is
*
decreased due to current release protection.
Both capacity and input change largely when temperature is 50 or less degrees F, as outdoor fan speed
*
is decreased due to low ambient temperature cooling control.
Both capacity and input change more largely at less than 32 degrees F of ambient temperature as
*
outdoor fan speed is decreased further.
32
50
32
50
08-10
68
86
66
68
86
66
104
115
104
115