SECTION 1 – SAFETY INFORMATION 1.1 – CAUTION CAUTION FLAMMABLE THIS EQUIPMENT IS INTENDED FOR USE WITH STANDARD METALWORKING FLUIDS (WATER-BASE & CUTTING OILS) INFLAMMABLE ONLY. IT SHOULD NOT BE USED WITH FLAMMABLE FLUIDS, (FUELS, PAINT, SOLVENTS, ETC.) CORROSIVE, TOXIC OR REACTIVE MATERIALS.
1.2 – PRECAUTIONS READ THROUGH THE "OPERATIONS MANUAL" COMPLETELY BEFORE ATTEMPTING TO OPERATE THE MACHINE. CLEANOUT, POT LID, INLET CAP AND HOSES MUST BE IN PLACE AND TIGHTLY SECURED BEFORE OPERATION IN THE DISCHARGE MODE. TANK DISCHARGE PRESSURE MUST NOT EXCEED 10 PSI. REGULATOR AND RELIEF VALVES ARE SET BEFORE SHIPMENT AND SHOULD NOT BE CHANGED AS THE USE OF EXCESSIVE PRESSURE COULD CAUSE SERIOUS INJURY OR DAMAGE.
SECTION 2 – THE SUMP CLEANER 2.1 – UNIT IDENTIFICATION WHEN ORDERING PARTS OR ASKING QUESTIONS REGARDING YOUR SUMP SHARK, IT IS IMPORTANT TO HAVE THE MODEL AND SERIAL NUMBER OF THE UNIT. THE MODEL AND SERIAL NUMBER CAN BE FOUND ON THE SHARK’S NAMEPLATE LOCATED ON THE BACK PANEL OF THE PUMP BASE.
2.2 – MODEL & SERIAL NUMBER THE MODEL NUMBER IDENTIFIES YOUR SHARK AND INDICATES STANDARD FEATURES ON YOUR MACHINE. THE SERIAL NUMBER IDENTIFIES YOUR SPECIFIC SHARK AND WILL HELP IDENTIFY ANY SPECIAL FEATURES THAT MAY BE UNIQUE TO YOUR SUMP SHARK. THE SERIAL NUMBER IS LOCATED ON THE NAMEPLATE.
2.3 – SUMP CLEANPER FEATURES PUMP-TO-TANK PUMP-TO-TANK DISCHARGE SUCTION CONNECTION CONNECTION SUCTION PORT DISCHARGE ON / OFF VACUUM/ PORT SWITCH PRESSURE GAUGE SE10 OPERATIONS MANUAL & PARTS LIST (Rev. 5/2022)
SECTION 3 – INSTALLATION 3.1 – ASSEMBLE DISCHARGE CONNECTION FOR SHIPPING PURPOSE, SOME MODELS MAY REQUIRE THE INSTALL OF THE DISCHARGE VALVE AND QUICK DISCONNECT ADAPTER. USE PIPE SEALANT ON ALL JOINTS AND TIGHTEN SECURELY. SE10 OPERATIONS MANUAL & PARTS LIST (Rev.
3.3 – LOOSE ITEMS SOME ITEMS MAY BE PACKAGED IN A BOX LOCATED ON THE SHIPPING PALLET. PACKAGES WITH FILTER BASKET OR FILTER ASSEMBLIES WILL HAVE FILTERS INSTALLED. PLEASE REVIEW YOUR PACKING LIST TO SEE WHAT ADDITIONAL ITEMS YOU WILL BE RECEIVING. POLY STRAINER BAG FINE...
3.4 – INITIAL STARTUP 1. CLOSE AND SECURE ALL TANK SUCTION AND DISCHARGE PORTS. SUCTION PORT DISCHARGE PORT 2. PLUG IN POWER CORD TO PROPER ELECTRICAL CIRCUIT. SEE NAMEPLATE. SE10 OPERATIONS MANUAL & PARTS LIST (Rev. 5/2022)
Page 11
RUN THE UNIT IN “SUCTION” MODE. WITH POWER SWITCH IN THE OFF, POSITION CONNECT THE PUMP-TO-TANK HOSE TO THE SUCTION CONNECTION. 4. TURN THE POWER SWITCH TO ON. THE VACUUM READING SHOULD INCREASE TO 13” HG. SE10 OPERATIONS MANUAL & PARTS LIST (Rev.
Page 12
5. TURN SWITCH OFF. THE NEGATIVE PRESSURE IN THE TANK WILL CAUSE THE PUMP TO ROTATE BACKWARDS UNTIL THE PRESSURE EQUALIZES. RUN THE UNIT IN “DISCHARGE” MODE. CHANGE THE PUMP-TO-TANK HOSE TO DISCHARGE CONNECTION. 7. TURN THE POWER SWITCH TO ON. THE PRESSURE READING SHOULD INCREASE TO 5-7 PSI.
9. MACHINE IS READY TO USE. SECTION 4 – OPERATION 4.1 – CLEANING A SUMP 1. ATTACH THE SUMP CLEANER HOSE TO THE SUCTION PORT, AND INSERT SUCTION TOOL INTO HOSE END. 2. RUN UNIT ON SUCTION MODE. (SEE INITIAL STARTUP 3.5, STEP 3.) 3.
4.2 – DISCHARGING FLUID FROM THE SUMP CLEANER 1. ATTACH THE SUMP CLEANER HOSE TO THE DISCHARGE PORT, AND CAP THE SUCTION PORT. 2. RUN UNIT ON DISCHARGE MODE. (SEE INITIAL STARTUP 3.5, STEP 6.) 3. POINT NOZZLE AT THE TARGET WHERE THE FLUID IS TO BE DISPENSED, SLOWLY OPEN DISCHARGE VALVE.
4.3.1 – F10 FILTER 4.3.1.1 – EMPTYING FILTER 1. FOR BEST RESULTS, DISCHARGE LIQUID FROM SUMP CLEANER AND LET FILTER DRAIN FOR A FEW MINUTES BEFORE DUMPING. 2. LOOSEN THE THREE (3) WING NUTS HOLDING THE POT LID IN PLACE. 3.
Page 16
2. TUCK HANDLES IN BETWEEN FILTER AND PERFORATED BASKET. MAKE SURE COTTON BANDING(POLY-FILTER) OR SIDES OF FILTER ARE LYING ON POT LID GASKET COMPLETELY WITHOUT CREASES. 3. RE-INSTALL POT LID AND WING NUTS. 5. WITH UNIT IN SUCTION MODE AND POT LID CAPPED, TURN UNIT ON AND TO TIGHTEN WING NUTS.
4.3.2 – F23 FILTER 4.3.2.1 – EMPTYING FILTER 1. FOR BEST RESULTS, DISCHARGE LIQUID FROM SUMP CLEANER AND LET FILTER DRAIN FOR A FEW MINUTES BEFORE DUMPING. 2. LOOSEN THE THREE WING NUTS ON FILTER ASSEMBLY. 3. LIFT FILTER OUT OF SUMP CLEANER TANK USING HOIST OR FORKLIFT. CAUTION: KEEP HANDS AND FINGERS CLEAR OF POT OPENING IN SUMP CLEANER WHEN REMOVING FILTER! SE10 OPERATIONS MANUAL &...
Page 18
4. POSITION FILTER ABOVE CONTAINER INTO WHICH THE SLUDGE IS TO BE EMPTIED. DISTANCE BETWEEN BOTTOM OF FILTER AND CONTAINER BOTTOM OR “D” DIMENSION, SHOWN IN FIGURE BELOW, AND SHOULD BE APPROXIMATELY 2 TO 3 FEET ON F23 TO PREVENT DAMAGE TO FILTER SLEEVE WHEN DUMPED.
Page 19
5. ATTACH LANYARD TO TRIGGER ASSEMBLY ON FILTER BOTTOM. 6. MOVE TO A SAFE DISTANCE FROM THE DUMPING ZONE (APPROXIMATELY 7 FEET). 7. PULL LANYARD TO RELEASE LATCH AND BOTTOM DOOR WILL OPEN DUMPING THE FILTER. 8. AFTER FILTER SLEEVE IS EMPTY, ROLL BOTTOM OF SLEEVE UP LOOSELY SO THAT THE BOTTOM END OF SLEEVE WILL BE CLOSED AND CLOSE BOTTOM DOOR.
Page 20
4.3.2.2 – INSTALLING FILTER 1. LOOSEN THE TWO WING NUTS ON THE FILTER LID AND REMOVE LID. 2. PLACE BOTTOM END OF FILTER SLEEVE IN FILTER. 3. FOLD UPPER 1 ½” OF FILTER SLEEVE COLLAR OUT OVER LIP OF FILTER SO THAT THE GASKET IN LID WILL CLAMP IT IN PLACE.
4.4 – CLEANING THE SUMP CLEANER 1. GENERALLY, DISCHARGING THE FLUID OUT OF THE SUMP CLEANER IS ALL THAT’S NEEDED. SOME SOLIDS WILL ACCUMULATE IN THE BOTTOM OF THE SUMP AND WILL REQUIRE A COMPLETE CLEANOUT OCCASIONALLY. 2. THE SE10 HAS AN EASY TO REMOVE CLEANOUT DOOR AND CAN ACCESSED BY LOOSENING THE TWO WINGNUTS.
THAT WILL KEEP YOUR SUMP CLEANER IN TOP-NOTCH, DEPENDABLE CONDITION. ANY WORN OR DAMAGED PART SHOULD BE REPLACED IMMEDIATELY. CECOR STOCKS SUMP CLEANER PARTS AND MOST CAN BE SHIPPED THE SAME OR THE NEXT DAY. CALL 1-800-356-9042 TO ORDER PARTS.
5.3 – MONTHLY MAINTENANCE 1. CHECK FOR WEAR ON POT LID WING NUTS AND STUDS. 2. INSPECT SUMP CLEANER HOSE. 3. GREASE THE SWIVEL CASTER AND WHEELS. SE10 OPERATIONS MANUAL & PARTS LIST (Rev. 5/2022)
SECTION 6 – TROUBLESHOOTING PROBLEM POSSIBLE CAUSES CORRECTIVE ACTION WILL NOT START POWER SUPPLY. MAKE SURE THE UNIT IS PLUGGED INTO THE PROPER VOLTAGE. CIRCUIT BREAKER. CHECK ELECTRICAL SUPPLY FUSES OR BREAKER. LOSS OF SUCTION VAC/PRES GAUGE READS CHECK FILTER. IF FULL, EMPTY. IF BLINDED, FULL VACUUM BUT HAS CLEAN OR REPLACE WITH COARSE FILTER NO SUCTION.
7.2 – TANK & PUMP 10,11 Part No. Description TANK ASSEMBLY CALL FOR INFO (NEED TO SPECIFY GALLON CAPACITY AND TRANSPORT) A220-807 H-TANK PUMP ASSEMBLY SE30 A220-507 PUMP-TO-TANK HOSE SP-217 DISCONNECT ADAPTER SP-198 DISCONNECT COUPLER SP-262BN COUPLER GASKET SE10 OPERATIONS MANUAL & PARTS LIST (Rev.
SECTION 9 – RECORD MODEL & SERIAL NUMBER WHEN YOU RECEIVE YOUR CECOR SUMP SHARK, RECORD THE MODEL NUMBER, SERIAL NUMBER AND DATE DELIVERED FOR YOUR RECORDS. MODEL #: ________________________________________ SERIAL #: ________________________________________ DELIVERED: ____________ / ____________ / ____________ SE10 OPERATIONS MANUAL & PARTS LIST...
Page 35
SE10 OPERATIONS MANUAL & PARTS LIST (Rev. 5/2022)