All-sun EM6000 Owner's Manual

True rms digital multimeter

Advertisement

Quick Links

EM6000, TRUE RMS
DIGITAL MULTIMETER
OWNERS MANUAL
http://www.all-sun.com
OEM & ODM manufacturer of test & measurement instruments in China
Read this owners manual thoroughly before use
6000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EM6000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for All-sun EM6000

  • Page 1 EM6000, TRUE RMS DIGITAL MULTIMETER OWNERS MANUAL http://www.all-sun.com OEM & ODM manufacturer of test & measurement instruments in China Read this owners manual thoroughly before use 6000...
  • Page 2: Warranty

    It has the functions of polarity indication, data hold, backlight, overrange indication, low battery indication, relative value measurement, max/min value measurement and automatic power-off. It can be operated easily and is an ideal measurement tool. http://www.all-sun.com...
  • Page 3 6. Provides low battery indication, automatic power-off, manual power-off, relative value measurement, and max/min value measurement. 7. Measures DC/AC voltage, DC/AC current, resistance, capacitance, frequency, diode, transistor, temperature (°C/°F ), continuity and duty cycle. 8. Provides overload protection for all ranges. 9. Low power consumption. http://www.all-sun.com...
  • Page 4: Safety Information

    Do not apply more than the rated voltage, as marked on the meter, between terminals or between any terminal and earth ground. Before use, verify the meter's operation by measuring a known voltage. When measuring current, turn off circuit power before http://www.all-sun.com...
  • Page 5 When in Relative Mode, the symbol " " is displayed. Caution must be used because hazardous voltage may be present. When in MIN mode, the symbol "MIN" is displayed. Caution must be used because hazardous voltage may be present. http://www.all-sun.com...
  • Page 6 CATII - Measurement Category II is for measurements performed on circuits directly connected to low voltage installation.(Examples are measurements on household appliances, portable tools and similar equipments .) Do not use the meter for measurements within Measurement Categories III and IV. http://www.all-sun.com...
  • Page 7 Remove test leads from the meter before opening the meter case or the battery cover. Because of anti-interference designs, the meter may stop working in strong interference environment. Turning on the meter again can solve this problem. http://www.all-sun.com...
  • Page 8 AC (Alternating Current) DC (Direct Current) DC or AC (alternating current or direct current) Important safety information. Refer to the manual. Dangerous voltage may be present. Be cautious. Earth ground Fuse Conforms to European Union directives Double insulated Low battery Diode http://www.all-sun.com...
  • Page 9 INSTRUCTION Meter Instruction Figure 1 http://www.all-sun.com...
  • Page 10 In frequency or duty cycle measurement mode, you can press this button to switch between frequency and duty cycle measurements. 4. " " button Press this button to hold the present reading on the display, and " " will appear as an indicator. Press this http://www.all-sun.com...
  • Page 11 To preserve battery life, set this switch to the "OFF " position if you don't use the meter. 7. "A" jack Plug-in connector for the red test lead for current ( 600mA*20A ) measurements. http://www.all-sun.com...
  • Page 12 Turning on the meter while holding down this button will disable the automatic power-off feature, and the symbol "APO" on the display will disappear. http://www.all-sun.com...
  • Page 13: Lcd Display

    How to Connect the Adapter Capacitance test socket Transistor test socket Figure 2 LCD Display 6 5 4 3 1 Figure 3 http://www.all-sun.com...
  • Page 14 ---Autorange mode is selected --- Automatic power-off mode is selected --- Maximum reading is being displayed ---- Minimum reading is being displayed ---- DC --- Negative sign --- AC ---- Battery is low and should be replaced immediately 18. Bar graph http://www.all-sun.com...
  • Page 15: Using The Bar Graph

    In the 600V range, for example, the major divisions on the scale represent 0, 100, 200, 300, 400, 500 and 600V. An input of -100V lights the negative sign and the segments up to the "10" on the scale. http://www.all-sun.com...
  • Page 16 Nanofarad; µ F: Microfarad; 1F=10 µ F=10 nF=10 Temperature unit °C , °F °C : Celsius degree; °F : Fahrenheit degree; a ( °F )= 32+1.8 x b ( °C ) Frequency unit Hz:Hertz; kHz:Kilohertz; MHz:Megahertz; 1MHz=10 kHz=10 http://www.all-sun.com...
  • Page 17: General Specification

    GENERAL SPECIFICATION Maximum Voltage between any Terminal and Earth Ground: 600Vrms Fuse Protection for "µAmA" Jack Inputs: 500mA, 1000V, FAST, Min. Interrupt Rating 20000A Fuse Protection for "A" Jack Inputs: 20A, 1000V, FAST, Min. Interrupt Rating 20000A Display: LCD, with a max. reading 9999 Overrange Indication: "OL"...
  • Page 18 DC Voltage Range Resolution Accuracy 10µV ±(1.0%+7) 60mV ±(0.8%+5) 600mV 0.1mV ±(0.5%+5) 10mV ±(0.8%+5) 600V 0.1V Input Impedance: 60mV and 600mV ranges: >100M the other ranges: 10M Overload Protection: AC600V AC Voltage Range Resolution Accuracy ±(2.0%+10) 10µV 60mV ±(1.6%+10) 600mV 0.1mV ±(1.5%+10) 10mV...
  • Page 19 DC Current Range Resolution Accuracy Remark 600.0µA 0.1µA autorange 6000µA 1.0µA ±(1.0%+7) 60.00mA 0.01mA autorange 600.0mA 0.1mA 6.000A autorange ±(1.5%+7) 10mA Overload Protection: For "µA/mA" jack inputs: Fuse, 500mA/1000V, fast action, For "A" jack inputs: Fuse, 20A/1000V, fast action, Max. Input Current: 20A ( For inputs > 5A : measurement duration<10 secs, interval >15 minutes ) AC Current Range...
  • Page 20 Note: When the input terminals are shorted, the display may show a reading. It doesn't matter and will not affect the measurement accuracy. Resistance Range Resolution Accuracy 600.0 ±(1.0%+5) 6.000k 60.00k ±(0.8%+5) 600.0k 6.000M ±(1.5%+5) 60.00M ±(3.0%+5) Overload Protection: AC600V Open Circuit Voltage: < 0.7V http://www.all-sun.com...
  • Page 21: Transistor Hfe

    0.01Hz 999.9Hz 0.1Hz ±(1.0%+5) 9.999kHz 99.99kHz 10Hz 999.9kHz 100Hz Not specified 9.999MHz 1kHz Input Voltage: 0.5 ~ 3Vpp Overload Protection: AC600V Note : Frequency measurements are autoranging. Transistor hFE Range Resolution Test Condition 4µA Vce 2.2V,I Overload Protection: AC600V http://www.all-sun.com...
  • Page 22 0.1°F ±(6.0%+9°F) 32°F ~ 752°F 0.1°F °F ±(1.5%+7.2°F) 752°F ~ 1832°F 1°F ±(1.8%+9°F) Temperature sensor : Type K thermocouple - Nickel Chromium/Nickel Silicon Note: Don't use the type k thermocouple supplied with the meter to measure temperature above 230°C. http://www.all-sun.com...
  • Page 23: Duty Cycle

    Overload Protection: AC600V Continuity Range Introduction Remark The built-in buzzer will sound if the resistance Open circuit voltage: is less than about 20Ω The buzzer will not < 0.7V sound if the resistance is more than about 70Ω Overload Protection: AC600V http://www.all-sun.com...
  • Page 24: Operation Introduction

    " is displayed on the LCD as an indicator. To exit the Data Hold mode, press the button again and the indicator " " will disappear. Note: For diode, continuity or transistor function, the Data Hold mode is not available. http://www.all-sun.com...
  • Page 25: Measuring Voltage

    Note: For frequency measurement, the display will show a zero value or other indefinite values if the voltage of the input signal is less than about 300mV rms. It is normal. http://www.all-sun.com...
  • Page 26: Measuring Current

    "Hz" and then measure the frequency. It means that you don't have to set the range switch to the "Hz/Duty" position for frequency measurement. Press the " " button twice to restore the meter to ac current function. http://www.all-sun.com...
  • Page 27: Measuring Resistance

    1. For resistance above 1M , the meter may take a few seconds to stabilize reading. This is normal for high resistance measuring. 2. When the input is not connected, i.e. at open circuit, "OL" will be displayed for the overrange condition. http://www.all-sun.com...
  • Page 28: Continuity Test

    If the circuit resistance is more than about 600 , the display will show "OL". Note : Before performing in-circuit continuity test, make sure that the circuit under test has all power removed and all capacitors are fully discharged. http://www.all-sun.com...
  • Page 29: Measuring Capacitance

    3. Because the meter measures capacitance by measuring the time of charging and discharging the capacitor, measuring a higher capacitance will take more time. For the range of 4000* F , it will take about 30 seconds for the meter to measure capacitance. http://www.all-sun.com...
  • Page 30: Measuring Frequency

    4. Read the reading. Note 1. For frequency measurements, the range exchange is automatic. The max. reading is 9999. Measurement scope is 0 ~ 10MHz. 2. The scope of the voltage of input signal should be : 0.5 ~ 3Vpp http://www.all-sun.com...
  • Page 31: Measuring Duty Cycle

    " V Hz" jack (Note:The polarity of the red lead is positive " " ) . 2. Set the range switch to " " position. 3. Press the "Select" button to make the display show " ". http://www.all-sun.com...
  • Page 32 If you want to measure a transistor accurately, please use a professional measurement tool. http://www.all-sun.com...
  • Page 33: Measuring Temperature

    3. Connect another end of the thermocouple to the object to be measured. 4. Read the reading on the display. 5. To change the meter between the celsius temperature mode and the fahrenheit temperature mode, press the "Select" button. http://www.all-sun.com...
  • Page 34: Auto Power Off

    You can use the supplieded data cable and the communication application to transfer the measurement readings to a computer in a real-time mode through the USB interface, and these readings will be displayed on the computer in several patterns, and can be stored as a file. http://www.all-sun.com...
  • Page 35: General Maintenance

    1. Set the range switch to the OFF position and remove all the test leads from the meter. 2. Shake out any dirt which may exist in the terminals. 3. Soak a new swab with alcohol. 4. Work the swab around in each terminal. http://www.all-sun.com...
  • Page 36: Replacing The Battery And Fuse

    Rejoin the battery cover and the gently rotate the screw-type lock by 90 clockwise. Note: Excess force will cause damage to the screw-type lock. Don't use a screwdriver which is not big enough. http://www.all-sun.com...
  • Page 37 To replace the fuse, remove the meter from its holster, remove the screws on the back cover, remove the back cover, replace the fuse with a new one of the same ratings. Rejoin the cover, reinstall the screws and the holster. http://www.all-sun.com...
  • Page 38 1 piece CD ( containing USB driver and the communication application ) : 1 piece http://www.all-sun.com OEM & ODM manufacturer of test & measurement instruments in China DISPOSAL OF THIS ARTICLE Dear Customer, If you at some point intend to dispose of this article, then please keep in mind that many of its components consist of valuable materials, which can be recycled.
  • Page 39 " button for about 2 seconds, the symbol "RS232" appears on the meter's LCD display. 5. Press and hold down the meter's " OPERATION INSTRUCTION After the installation finishes, click EM6000.exe to run it, the following window appears. It functions like a It functions like a needle...
  • Page 40 Min box and the Max box respectively, the readings beyond the the limits are not visible in the chart. If you select the Auto mode, the computer will automatically adjust the scale on the Y axis to fit all the recorded data. http://www.all-sun.com...
  • Page 41 9 Page number : Indicates the page number of the currently shown chart. After the communication connection has been disconnected, input a page number in this box, then press ENTER key to display the chart of this page number. 10 Total page number : Indicates the total page number. http://www.all-sun.com...