Installation Instructions

Allowable Clearances for Closet Installation

When installed in closet (washer only/washer dryer stacked) :
Sides, Rear, Front 1/2 in. (1.27 cm), Top= 1 in. (2.54 cm)
Closet door ventilation requirement: A louver having minimum 23 in2
(148 cm2) air opening located at 3 in (7.62 cm) from the bottom of
closet door.

Stacked Installation

You can stack your Blomberg washer and dryer (model no: DHP
24412 W / DHP 24401 W) by using a special stacking kit (Part
No.2985300200). If necessary, consult your dealer or technical
service for supplying the stack kit. In stacked closet installation,
following configuration is necessary:
A louver having minimum 23 in
in (7.62 cm) height from the bottom of closet door (for washer) & A
louver of minimum 46 in2 (297 cm
cm) distance from the top of closet door (for dryer).

Removing packaging reinforcement

Tilt the washer to remove the packaging reinforcement. Remove the
packaging reinforcement by pulling the ribbon.