FOR THE PLUMBER

Water Inlet
Air Cooled Models: The recommended water
supply is cold water. Use 3/8" O.D. copper tubing,
connect to the 3/8" male flare at the back of the
cabinet. Install a hand valve near the machine to
control the water supply.
WATER
COOLED
HAND SHUT
OFF VALVE
CONNECT TO
COLD WATER
FILTER, FIELD
INSTALLED
(OPTIONAL)
Water Cooled Models: A separate 3/8" O.D.
copper line is recommended, with a separate hand
valve to control it. It is connected to a 3/8" FPT
condenser inlet at the back of the cabinet. The
water pressure to all lines must always be above
20 psig, and below 120 psig.
CONFORM TO ALL APPLICABLE CODES
WATER INLET
3/8" FLARE
Air Cooled Models: There is one 3/4" FPT drain at
the back of the cabinet, the drain line is of the
gravity type, and 1/4 inch per foot fall is an
acceptable pitch for the drain tubing. There should
be a vent at the highest point of the drain line, and
the ideal drain receptacle would be a trapped and
vented floor drain.
Water Cooled Models: In addition to the above
mentioned drain, a separate condenser drain must
be installed. Connect it to the 1/2" condenser drain
connection at the back of the cabinet.
Storage Bin: A separate gravity type drain needs
to be run, similar to the air cooled drain.
Insulation of this drain line is recommended.
August 1993
Page 5
NME1250
Drains
Use only 3/4" rigid tubing.
ICE MAKER
BIN DRAIN
3/4" FPT
DRAIN
3/4" FPT