Download Print this page

Qlightec ETG50L Series Manual page 2

Industrial led beacon

Advertisement

Wiring Instructions
• ETG50L series can be wired by using both external contact
and transistor.
• Wiring to transistor, use the PNP transis- tor. Please wire properly
based on wiring instructions.
ETG50L, ETG50L-BZ
Red
Amber
Green
Brown
Black
Red
Amber
Green
Brown
Black
• External power/ signal line - UL1007 AWG22(0.3sq) 400mm
Installation Environment and Protection Rating
• This product is designed for indoor use with protection rating
of IP65/IP54.
• If the product is installed in locations that subject it to excessive dust
or water other than the designated IP protection rating
indicated, it may cause malfunction or damage to the product.
• For further information, please visit our website (www.qlight.com).
External contact
Red
Amber
Green
Buzzer
Steady
Fuse
Power
External transistor-PNP
Red
Amber
Green
Buzzer
Steady
Fuse
Power
Product Operation Inquiry / Customer Support +82-51-620-4100
You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.

※ ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Parts Definition/ Installation
ETG50L, ETG50L-BZ
• Please disassemble the M5 bolts placed in mounting bolts and
place the bracket on to desired mounting surface.
• Tighten the flange nuts from the opposite side of the mounting
surface.
Mounting Hole Specifications
• Machine holes on the mounting surface referring to the
diagram below.
4-Φ6 HOLES
Min.Ø5 CABLE ENTRY
PCD 70
Lens(PC)
Housing(ABS)
Bolt
Bracket(ABS)
Flange nut
www.qlight.com