For The Installer - Scotsman FM2400RL Service Manual

Scotsman fm2400rl ice machine: user guide
Table of Contents

Advertisement

FOR THE INSTALLER

Select the Location:
The unit can only be installed indoors within
the limitations described on page 2.
The ice machine will have to be connected
to the building's R-404A refrigeration
system, check to be sure that the system
has enough extra capacity to handle a
minimum of additional 16,000 BTU's per
0
hour @ 110
F. liquid line temperature
0
(assume a 0
F. evaporator temperature).
Storage Bin:
Scotsman's B90 will be the presumed bin of
choice. If using the bin extension BX87,
install heavy duty leg kit KLP4 and place
the bin into position.
Remove the paper tape from the bin edge
gasket, and install the bin extension onto
the B90.
Remove the paper tape from the bin
extension top edge, and using a
mechanical lift, install the FME2400RH onto
the top of the storage bin assembly.
Fasten the ice machine to the bin using (4)
5/15-18 2.5" cap screws.
Level the assembly by:
a. Turning the leg levelers in or out on the
standard legs.
b. Use shims under the heavy duty legs of
the KLP4.
Locate the Nameplate: The nameplate is
located on the back panel of the machine,
and contains the electrical characteristics
particular to the unit being installed.
Refrigeration Installation:
The skills of a refrigeration technician are
required to connect the ice machine to the
buildings refrigeration system.
Notes:
Suction Line and Liquid Line Stubs are
at the back of the cabinet.
1.5 ounces of the appropriate refrigerant is in
the system as a holding charge.
Be sure there is enought BTU capacity.
Be sure the liquid connection is NOT in series
with another liquid line valve.
Local Codes must be observed.
A P-trap should be installed where there will be
more than 10' of vertical rise in the suction line.
TYPICAL INSTALLATION: ALLOW ROOM FOR SERVICE ACCESS
March 1997
Page 3
Double System RL
Ice Machine
B90 STORAGE BIN
BX87 BIN
EXTENSION