For The Installer - Scotsman CME500R Service Manual

Scotsman cme500r ice machine: user guide
Table of Contents

Advertisement

CME500R

FOR THE INSTALLER

The CME500R will fit the following Scotsman ice
storage bins:
*BH550
*HTB500, HTB350, HTB250
BH800 (with bin top KBT23)
BH900 (with bin top KTB22)
BH1360
It will also fit these Scotsman Dispensers:
CD200
IS150 (with adapter kit KADCM1)
RS150 (with adapter kit KADCM1)
*These smaller bins are recommended.
Scotsman Ice Systems are designed and
manufactured with the highest regard for safety
and performance. They meet or exceed the
standards of U.L., N.S.F., and C.S.A.
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any parts and/or other components not
specifically approved by Scotsman.
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and designs are subject to change
without notice.
Model Number Dimensions
(without bin)
W" x D" x H"
CME500RE-1A 30" X 24" X 27" 115/60/1 HP62
* Minimum Circuit Ampacity is used to determine wire size and type per the National Electric Code.
** The unit is shipped with the full charge in the receiver. For re-charging purposes, if the nameplate charge
is different than this number, go by the nameplate.
*** Or HACR type circuit breakers.
Use Scotsman remote condenser RCE501-1A. or
ERC101-1A.
Use precharged tubing kit
RTE25 (25') or RTE40 (40")
The condenser and the tubing kit both contain a
small charge of refrigerant that matches the ice
maker's refrigerant type.
This ice system (except remote condenser) is
designed to be installed indoors, in a controlled
environment.
A remote condenser and precharged tubing kit are
required to assemble this ice system.
The normal finish for the machine is enamel. An
optional stainless steel panel kit (SPKCMD-1) can
be field installed. It contains a stainless steel top,
side panels, service panels, and front panel.
Basic
Refrigerant
Electrical
Type
(R-404A)
Air Temperature
Water Temperature
Water Pressure
Voltage
December 1995
Page 2
Minimum
Maximum
Circuit
Fuse
Ampacity*
Size***
20
20
Operating Limitations (except remote condenser)
MINIMUM
50
40
20 psi
-10%
Refrigerant
Condenser
Charge**
Type
HP62
208 oz.
Remote Air
MAXIMUM
0
0
F.
100
F.
0
0
F.
100
F.
80 psi
+10%