Scotsman CME1002W User Manual page 15

Scotsman cme1002w ice machine: user guide
Table of Contents

Advertisement

COMPONENT DESCRIPTION
Electric Water Inlet Valve
The water inlet solenoid valve fills the reservoir
assembly with water. Excess water overflows out
the overflow standpipe located at the back of the
reservoir. This action fills and rinses the reservoir
during each harvest cycle. The flow rate is .75
g.p.m.
Water Distribution System
The water distribution system evenly supplies
water to all cells of the evaporator plates. The
water pump pumps water from the reservoir up the
vertical tygon tube to the tee. From there water is
channeled through the water manifold to the water
distributors, above each evaporator plate, and
from six holes within each distributor, water flows
to the cells of each side of the evaporator plates.
Gravity flow returns the unfrozen excess portion of
water to the reservoir for recirculation.
WATER
REGULATING
VALVE
CME865W & CME1002W
Reservoir
The reservoir, located below the evaporators,
stores the inlet water charge, and collects the
water that flows over the evaporator plates. Above
the reservoir, but below the evaporators are the
cube chutes, designed to retain any water splash
from ice making or harvest. Most ice will be falling
into the bin below the center evaporator.
High Pressure Safety Control
This is a manual reset control that shuts down the
icemaker, should the discharge pressure ever
reach 400 PSIG.
December, 1994
Page 15
WATER
DISTRIBUTION
SYSTEM
HIGH PRESSURE
CUT OUT
ELECTRIC WATER VALVE
EVAPORATOR
WATER PUMP
RESERVOIR

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cme865w

Table of Contents