Duct Board Installation
1. Take out the duct board mounting bracket, remove the wall plate from the control and put the
rest of the control in a safe location until after wiring is completed .
2. Cut a 5 . 7 5" x 5 . 2 5" rectangular opening in the return plenum . Save the piece cut out to
insulate the duct board bracket around the controller . The display of the control will run
parallel with the long dimension . DO NOT MOUNT THE CONTROL IN A POSITION WHERE IT IS
FACING DOWN .
3. Use the supplied #8 x 1/2" type 25 pan head screws to mount the control wall plate to the
duct board mounting bracket .
4. Place the bracket in the cut out and seal in place using metal foil tape and/or mastic .
5. Insulate the duct board bracket around the wall plate using the plug cut out of the duct board .
FRESH AIR DUCT
6" MIN
RETURN DUCT
DUCT
BOARD
5-3/4"
BRACKET
5-1/4"
WALL PLATE
#8 PAN HEAD
DUCT BOARD
TYPE 25 SCREW
RETURN PLENUM
USE CUT-OUT INSULATION
TO INSULATE DUCT BOARD
BRACKET AROUND CONTROLLER
6 English
MOUNT VENT CONTROLLER
SIDE AND TOP ONLY
MOUNTING THE CONTROLLER IN A CLOSET RETURN PLENUM
NOTE: Do not mount directly in the path of the outdoor air . Mount the control where it will
sense the relative humidity of the return air .
1. Remove the wall plate from the control and put the rest of the control in a safe location until
after wiring is complete .
2. Use spacers or brackets to mount the controller to an inside wall surface or return plenum/
duct surface that is at room temperature (i . e . do not mount to supply ductwork or to the air
handler/furnace) to space the wall bracket a minimum of ½" away from the surface .
3. Mount the wall bracket to the surface using #8 screws (field supplied – do not use flat head
screws) and wall anchors (field supplied) if mounting to drywall . Ensure that there is room
for air to flow behind the wall bracket . DO NOT install screws in the wall bracket anywhere
except intended mounting holes.
SPACER (2)
90-2264
WALL PLATE
1/2"
#8 SCREW (2) DO NOT
USE FLAT HEAD SCREWS
90-2278
English 7