Hide thumbs Also See for NIMBUS:
Table of Contents

Advertisement

Quick Links

USER MANUAL
NIMBUS card

Advertisement

Table of Contents
loading

Summary of Contents for Salicru NIMBUS

  • Page 1 USER MANUAL NIMBUS card...
  • Page 2: Table Of Contents

    3.5.9. Logs / Event log. 1.3. DESCRIPTION OF THE SYSTEM. 3.5.9.1. DCS series. 1.3.1. Introduction. 1.3.2. NIMBUS MAXI vs NIMBUS MINI compatibility. 3.5.9.2. Rest of series. 1.3.3. Features of the system. 3.5.10. Backup (DC-S series only). 3.5.11. Actions. 1.3.4. Optional systems.
  • Page 3 Manual registration through the remote maintenance portal. 6.3.1.2. Automatic registration with QR Code. 6.3.2. Creating notifications associated with a device. 6.3.2.1. Web notifications. 6.3.2.2. Email notifications. 6.3.2.3. SMS notifications. 6.3.3. Password recovery. 7. APPENDIX II. GENERAL TECHNICAL SPECIFICATIONS. USER MANUAL NIMBUS card...
  • Page 4: Presentation

    HDMI interface to connect the card using an HDMI HDMI port micro cable. MicroSD connector Enables the NIMBUS card version to be updated using a MicroSD. Connector for flat bus cable to connect the card to Display connector an LCD.
  • Page 5: Nimbus Maxi Vs Nimbus Mini Compatibility

    Onboard panel Web panel that enables remote monitoring of the device. As it is dependent on the NIMBUS card, if it is not Tab. 4. Optional services available connected it will not be possible to access the panel. Communication Reading data through MODBUS.
  • Page 6: Installation And Startup

    The fixed IP is always available at the address 100.0.0.1. To access it, connect one end of the Ethernet cable to the dedi- cated slot on the NIMBUS card and the other end to your computer. Configure the point-to-point connection by accessing network con- Fig.
  • Page 7: Initial Configuration

    2.2. INITIAL CONFIGURATION. The NIMBUS card comes already configured with the necessary parameters so that you can immediately use the onboard panel and all of its functionalities. These are the following: Auto-configuration of the device into which it is installed.
  • Page 8: Onboard Panel

    ‘View certificate’ • then on ‘Install certificate’. Lastly, click on ‘Yes’ to confirm the installation. Restart the browser and access the panel. This time, the • Fig. 8. Screen for importing the certificate locked. warning message will not be displayed. SALICRU...
  • Page 9: Mozilla Firefox

    ‘Privacy & Security’. Navigate to the end of the tab until you find the section of ‘Certificates’. Click on ‘View certificates...’ (Fig. 16). Fig. 13. ‘Export ... ’ window USER MANUAL NIMBUS card...
  • Page 10: Chrome / Opera

    The next time you access the panel, the ‘Details’ the site certificate. Click on the tab, followed by the warning message will no longer be displayed: ‘Export ...’ button that appears at the end of it, (Fig. 21). Fig. 18. ‘Accept risk and continue’ window. SALICRU...
  • Page 11 (Fig. Fig. 22. ‘Import ... ’ screen. 25). The system will require the password of your computer before proceeding. When prompted for the label, enter ‘Nimbus’ click on ‘OK’. USER MANUAL NIMBUS card...
  • Page 12: Local Connection (Point-To-Point)

    To do this, follow the steps described in the previous section (3.1.1 Fig. 28. Cache and Databases menu Local connection). Confirm all of your changes by clicking on the ‘OK’ button. Delete the browser’s cache memory. SALICRU...
  • Page 13: Screen Login

    - Modify some device - Only display device + F5. parameters. measurements. - Modify NIMBUS card Important: if you have not acquired additional measure- parameters. ment modules for certain series, such as the SLC X-PERT, - Measurements display. the value corresponding to that measurement will be nega- tive.
  • Page 14: Diagram And Measurements

    The corresponding element does not exist in the de- – vice. Surrounding the diagram, a summary of the relevant measure- ments for the different parts of the device is shown in order to complete the basic information (block 2 in Fig. 31). SALICRU...
  • Page 15: Adapt-X & Adapt2 Series

    Fig. 32. Example of modules in the ADAPT2 and ADAPTX series. By clicking on any of them, an individualised monitor will appear showing its own diagram and measurements, as it can be seen in the following figure: Fig. 33. Diagram relating to a single module. USER MANUAL NIMBUS card...
  • Page 16: Alarms

    (block 3). Non-active alarms are shown in green and active in red. An ac- knowledged alarm on the device (ACK) will also be shown in red. Fig. 36. Part of the display where the different alarms are shown. SALICRU...
  • Page 17: Device

    Page of read-only. This shows a summary of the technical param- When configuring in the "Alarms" section, a server stop order eters of the device and the version installed in the NIMBUS card. will be launched when the threshold exceeds the limit value. (see RCCMD).
  • Page 18: Register Settings

    If the device is connected but there is a problem with the NIMBUS card, the data sent for the most recent two-hour interval will be displayed (see Fig. 42), provided the device has been connected for Fig.
  • Page 19: Actions (Dc-S Series Only)

    .csv format. 3.5.9.2. Rest of series. All the alarm events triggered on the device will be stored in this section, up to 500 events. Go to “Device > Event logs”. Fig. 48. Restoring factory settings. USER MANUAL NIMBUS card...
  • Page 20: Actions

    In the event that there is a route in red, it could mean that there is quired for these fields. a port that is not accessible or that the entry to the card is being To access the NIMBUS card you must know the IP assigned by banned. DHCP.
  • Page 21: Date & Time

    ‘4.2.2. Sender port.’. NIMBUS is connected in order to read information, as well as the For each of the possible groups of alarms, activate or deactivate parameters of the protocol for establishing a connection to the de- the functionality by moving the button. Only when a group is active, vice.
  • Page 22: Select Model

    When it is inserted for the first time, the NIMBUS card will auto- matically detect the device type. However, you can change the model if you wish to connect the NIMBUS card to another device.
  • Page 23: Installing The Rccmd Software

    RCCMD’. In order for this function to work, two elements are required: a receiver and a sender. The NIMBUS card will always work as a sender, as it will have the capacity to detect the specified shut- down conditions. The receiver can be one or various servers, de- pending on whether you have set a single IP indicating a single server, or a broadcast IP.
  • Page 24: Unix And Linux

    Fig. 68. RCCMD: System status. If the RCCMD is not running in the destination server, the NIMBUS card will not be able to send it the information it requires to function correctly. SALICRU...
  • Page 25: Sender Ip

    IP has been correctly configured in these cards and corresponds to the server in question. In other words, even if the IP of the sender (i.e. the NIMBUS card) is not configured, the Fig. 71. Advanced Settings screen.
  • Page 26: Activation Of Contracted Services

    5. ACTIVATION OF CONTRACTED SERVICES. If you have purchased an extra service with your NIMBUS commu- nications card, you must activate it via the embedded web panel. To use this method, follow the steps below: Connect to the web panel. Refer to section “3.1 Access to the panel”...
  • Page 27 IEC 61850 Protocolo de comunicación secundario. Permite recibir MMS (*) The RCCMD service must not be activated by code on the NIMBUS communi- cations card, but by downloading the RCCMD client. For more information, refer to section “4. Installing the RCCMD software”.
  • Page 28: Appendix I. Connectivity

    443 and 8883 mqtt.googleapis.com 443 y 8883 For all SALICRU devices compatible with the NIMBUS card, the www.googleapis.com data displayed on the onboard panel can also be uploaded to oauth2.googleapis.com SALICRU’s online platform. This platform allows users to view the status of the device without needing to be on the same network.
  • Page 29 UPS through the screen in order to see the change of the connectivity icon (cloud) reflected once the device is registered. Important: If an unexpected event occurs during the WiFi connection process, review the following board. USER MANUAL NIMBUS card...
  • Page 30: Use Of And Access To The Remote Maintenance

    Within a few below: minutes you will receive an email confirming your account. Go to https://nimbus.salicru.com/. Remember that this message has an expiry date. To be used within 15 minutes of receipt. Create an account (if you do not already have one), using the “Create an account”...
  • Page 31: Automatic Registration With Qr Code

    That way, if you have registered other each device. However, email accounts and phones can be SALICRU devices, you can use this field to easily differentiate be- associated so that more than one person can receive the same tween them.
  • Page 32: Password Recovery

    Spam folder if you cannot find the email in your inbox. After you click on the link contained in the email you will be able to ‘Save’ create a new password. Click on to set the new password. SALICRU...
  • Page 33: Appendix Ii. General Technical Specifications

    Flash memory 4GB, 8bit MMC integrated PMIC TPS65217C PMIC regulator and an additional LDO. Debug support Optional Onboard 20-pin CTI JTAG SD/MMC connector MicroSD, 3.3V Audio HDMI interface, stereo Tab. 10. Technical specifications of the NIMBUS card. USER MANUAL NIMBUS card...
  • Page 34 ...................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... SALICRU...
  • Page 35 ...................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... USER MANUAL NIMBUS card...
  • Page 36 REF. EL139M01 REV. M CODE 401* Avda. de la Serra 100 08460 Palautordera BARCELONA Tel. +34 93 848 24 00 sst@salicru.com SALICRU.COM Information about the technical support and ser- vice network (TSS), the sales network and the warranty is available on our website: www.salicru.com...

Table of Contents