Section Vii. Inspection Criteria - Kenco KL16K8T18 Operator's Manual

Concrete median barrier handling device
Table of Contents

Advertisement

Section VII.
®
THE KENLIFT
SHALL BE REMOVED FROM SERVICE AND TAGGED APPROPRIATELY
UNTIL RECERTIFICATION BY A QUALIFIED INDIVIDUAL IN ANY OF
THE FOLLOWING CONDITIONS:
A. General
1. Cracking in any component or member.
2. Cracking in any weld.
3. Visible distortion in any member.
4. Visible distortion in any Bolt/Pin/Shaft.
B. Specific
1. Lift Bail
a. The lift bail shall be replaced if a
20% loss in cross-sectional area from
the original member(s) can be
demonstrated. Note: cross section of
welds, "mushroomed" wear faces,
and burrs are not accounted for as
cross-sectional area. (See ill.)
2. Holes
a. Any members through which bolted or pinned connections pass shall be
replaced if a 10% loss in cross-sectional area from the original member(s)
can be demonstrated. Note: cross section of welds, "mushroomed" wear
faces, and burrs are not accounted for as cross-sectional area.
3. Pins/Bolts
a. Any visible deformation of a pin, shaft or bolt shall require replacement of
that part.
4. Pads – Replace if:
a. For units utilizing urethane gripping pads, if surface of any given mounting
bolt is not at least 3/32" below the surface of the pad,.
b. Any de-lamination of the pad from the backing plate.
c. Any scarring, chunking, or missing pad material constituting a total
combined loss of surface area greater than 3 sq. in. per pad.
d. Any single scar, chunk, or missing pad face that is greater than 1 sq. in per
pad.
®
KENCO Kenlift
Operation Manual
Inspection Criteria
UNIT AND ALL OF ITS ASSOCIATED COMPONENTS
170 State Route 271
Ligonier, PA 15658
1-800-653-6069
8