  • Page 1 DS-K3BC430LX Series Swing Gate...
  • Page 2 WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES,...
  • Page 3 During the use of device, personal data will be collected, stored and processed. To protect data, the development of Hikvision devices incorporates privacy by design principles. For example, for device with facial recognition features, biometrics data is stored in your device with encryption method;...
  • Page 4 DS-K3BC430LX Series Swing Gate Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 5 DS-K3BC430LX Series Swing Gate under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU,the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points.
  • Page 6 DS-K3BC430LX Series Swing Gate Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Dangers and Cautions: Dangers: Neglecting any of the warnings may cause serious injury or death.
  • Page 7 DS-K3BC430LX Series Swing Gate Do not place the device in extremely hot (refer to the specification of the device for the detailed ● operating temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation. The device cover for indoor use shall be kept from rain and moisture.
  • Page 8 DS-K3BC430LX Series Swing Gate Available Models Product Name Model Swing Gate DS-K3BC430LX...
  • Page 9: Table Of Contents

    DS-K3BC430LX Series Swing Gate Contents Chapter 1 Overview ........................1 1.1 Introduction ........................... 1 1.2 Main Features ........................2 Chapter 2 System Wiring ......................3 Chapter 3 Install Pedestals ......................6 Chapter 4 General Wiring ......................10 4.1 Components Introduction ....................10 4.2 Wiring ..........................
  • Page 10 DS-K3BC430LX Series Swing Gate 5.3 Activate via Web Browser ....................26 Chapter 6 Quick Operation via Web Browser ................27 6.1 Time Settings ........................27 6.2 Administrator Settings ......................27 Chapter 7 Operation via Web Browser ..................28 7.1 Login ............................ 28 7.2 Overview ..........................
  • Page 11 DS-K3BC430LX Series Swing Gate 8.1 Configuration Flow of Client Software ................. 52 8.2 Device Management ......................53 8.2.1 Add Device ........................53 8.2.2 Reset Device Password ....................55 8.2.3 Manage Added Devices ....................56 8.3 Group Management ......................57 8.3.1 Add Group ........................57 8.3.2 Import Resources to Group ..................
  • Page 12 DS-K3BC430LX Series Swing Gate Appendix C. Event and Alarm Type ................... 86 Appendix D. Table of Audio Index Related Content ..............87 Appendix E. Error Code Description ..................88...
  • Page 13: Chapter 1 Overview

    DS-K3BC430LX Series Swing Gate Chapter 1 Overview 1.1 Introduction Figure 1-1 Appearance...
  • Page 14: Main Features

    DS-K3BC430LX Series Swing Gate 1.2 Main Features Supports control mode, remain open mode and remain closed mode in both entrance and exit ● direction. Self-detection, self-diagnostics, and automatic alarm ● Fire alarm passing ● When the fire alarm is triggered, the barrier will be open automatically for emergency evacuation.
  • Page 15: Chapter 2 System Wiring

    DS-K3BC430LX Series Swing Gate Chapter 2 System Wiring The preparation before installation and general wiring. Steps Note The device should be installed concrete surface or other flat non-flammable surface. ● If the installation area is too close to the wall, make sure the distance between the pedestal and ●...
  • Page 16 DS-K3BC430LX Series Swing Gate Figure 2-1 Dimension 1. Draw a central line on the installation surface of the left or right pedestal. 2. Draw other parallel lines for installing the other pedestals. Note The distance between the nearest two line is L + 180 mm. L represents the lane width.
  • Page 17 DS-K3BC430LX Series Swing Gate 4. Bury cables. Note Interconnecting cable (available for two pedestals and above): The recommended length is L ● +1.5 m. Network communication cable: It is recommended to use CAT5e or the network cable has better performance.
  • Page 18: Chapter 3 Install Pedestals

    DS-K3BC430LX Series Swing Gate Chapter 3 Install Pedestals Before You Start Prepare for the installation tools, check the device and the accessories, and clear the installation base. Steps Note The installation diagram is for illustration. For details, please refer to Wiring for video guide.
  • Page 19 DS-K3BC430LX Series Swing Gate Figure 3-2 Remove Decorative Ring and Cable Protection Panel 5. Use a cross screwdriver to fix the top plastic part, and use a hexagon wrench to fix the rotary tube.
  • Page 20 DS-K3BC430LX Series Swing Gate Figure 3-3 Fix Top Plastic Part and Rotary Tube 6. Fix the barrier and decorative parts.
  • Page 21 DS-K3BC430LX Series Swing Gate Figure 3-4 Fix Barrier...
  • Page 22: Chapter 4 General Wiring

    DS-K3BC430LX Series Swing Gate Chapter 4 General Wiring Note The supplied interconnecting cables need connecting on-site: CAT5e Communication cable. The ● cable is 3 m in length and put inside the package. 4.1 Components Introduction By default, basic components of the turnstile are connected well. The pedestals can communicate by wiring the interconnecting cables.
  • Page 23: Terminal Description

    DS-K3BC430LX Series Swing Gate 4.3 Terminal Description 4.3.1 General Wiring The general wiring of lane control board, access control board and optional board.
  • Page 24: Lane Control Board Terminal Description

    DS-K3BC430LX Series Swing Gate Figure 4-2 General Wiring Note It is recommended to use Hikvision matched distribution cabinet (sold separately) to covert the ● AC mains power to 24 V. The ① and ② refer to the two sides of a same board.
  • Page 25: Access Control Board Terminal Description (Optional)

    DS-K3BC430LX Series Swing Gate Figure 4-3 Lane Control Board 4.3.3 Access Control Board Terminal Description (Optional) Access control board is mainly used for authority identification in places with high security levels such as public security or judicial place, external device accessing, and communication with the...
  • Page 26 DS-K3BC430LX Series Swing Gate Figure 4-4 Access Control Board Note RS-485A corresponds to UART 5 on web and is for QR code scanner connection at entrance by ● default; RS-485C corresponds to UART 7 on web and is for card reader connection at entrance by default.
  • Page 27 DS-K3BC430LX Series Swing Gate Press the Reset button for 5 s and the device will start to restore to factory settings. ● The DIP switch is for study mode setting and keyfob paring. For detailed information about the ● DIP switch, see DIP Switch Description.
  • Page 28: Optional Board Terminal Description

    DS-K3BC430LX Series Swing Gate 4.3.4 Optional Board Terminal Description The optional board contains the sub-1G antenna interface, 485/232 interface, 12 V output interface, loudspeaker interface, debugging port, Wiegand/exit button interface, BUS interface, 5 VDC output and communication interface. Figure 4-6 Optional Board Terminal 4.3.5 Card Reader Board Terminal Description...
  • Page 29: Wiring

    DS-K3BC430LX Series Swing Gate Note There are 2 RS-485 interfaces on the access control board for entrance. Refer to Access Control ● Board Terminal Description (Optional) for details. There are 2 RS-485 interfaces on the optional board for exit. Refer to for details.
  • Page 30: Exit Button Wiring

    DS-K3BC430LX Series Swing Gate Figure 4-10 Remaining Open Figure 4-11 Remaining Closed 4.3.9 Exit Button Wiring The main and sub lane control board each has 1 button interface, which can be connected to exit button or face recognition device. Figure 4-12 Exit Button Wiring...
  • Page 31: Device Settings Via Button

    DS-K3BC430LX Series Swing Gate Note The face recognition devices are powered via 12 VDC power output interface of the main and ● sub lane control board. Barrier open at the entrance: connect to BTN1 and GND. ● Barrier open at the exit: connect to BTN2 and GND.
  • Page 32 DS-K3BC430LX Series Swing Gate Press to open the barrier from the entrance position. ● Double press to open the barrier from the exit position. ● Parameter Configuration Button LEFT: Press to add 10 to configuration data. ● RIGHT: Press to add 1 configuration data.
  • Page 33 DS-K3BC430LX Series Swing Gate Figure 4-14 Procedure Steps: 1. Hold OK button for 3 s until one beep occurs. The device enter the configuration mode. Level 1 menu lights up. The display screen displays the configuration No. 1. 2. In the Level-1 menu, press LEFT (plus 10) once and press RIGHT (plus 1) twice to set the configuration No.
  • Page 34: Set Study Mode Via Button

    DS-K3BC430LX Series Swing Gate Note - The configuration No. will display in a cycle. - Each configuration No. refers to a function. For details about the configuration No. and its related function, see Button Configuration Description . 4.4.2 Set Study Mode via Button Enter the study mode through button configuration to set the closed position of the device barrier.
  • Page 35: Initialize Device

    DS-K3BC430LX Series Swing Gate 3) Set the configuration No. in the Level-2 menu to 2. The device will enter the keyfob pairing mode. 2. Hold the Close button for more than 10 seconds. The keyfob's indicator will flash if the pairing is completed.
  • Page 36: Chapter 5 Activation

    Get the SADP software from the supplied disk or the official website http:// ● www.hikvision.com/en/ , and install the SADP according to the prompts. The device and the PC that runs the SADP tool should be within the same subnet.
  • Page 37: Activate Device Via Ivms-4200 Client Software

    DS-K3BC430LX Series Swing Gate Status of the device becomes Active after successful activation. 5. Modify IP address of the device. 1) Select the device. 2) Change the device IP address to the same subnet as your computer by either modifying the IP address manually or checking Enable DHCP.
  • Page 38: Activate Via Web Browser

    DS-K3BC430LX Series Swing Gate Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
  • Page 39: Chapter 6 Quick Operation Via Web Browser

    DS-K3BC430LX Series Swing Gate Chapter 6 Quick Operation via Web Browser 6.1 Time Settings Click in the top right of the web page to enter the wizard page. After setting device language, you can click Next to enter the Time Settings page.
  • Page 40: Chapter 7 Operation Via Web Browser

    DS-K3BC430LX Series Swing Gate Chapter 7 Operation via Web Browser 7.1 Login You can login via the web browser or the remote configuration of the client software. Note Make sure the device is activated. For detailed information about activation, see Activation .
  • Page 41: Person Management

    DS-K3BC430LX Series Swing Gate You can check if the device is working properly. Click View More to view the detailed component status. Remote Control The door is opened/closed/remaining open/remaining closed. Real-Time Event You can view the event Employee ID, Name, Card No., Event Type, Time, and Operation. You can also click View More to enter the search conditions, including the event type, employee ID, the name, the card No., the start time, and the end time, and click Search.
  • Page 42 DS-K3BC430LX Series Swing Gate Figure 7-2 Add Person Add Basic Information Click Person Management → Add to enter the Add Person page. Add the person's basic information, including the employee ID, the person's name, and person type. If you select Visitor as the person type, you can set the visit times.
  • Page 43: Search Event

    DS-K3BC430LX Series Swing Gate Authentication Settings Click Person Management → Add to enter the Add Person page. Set Authentication Type as Same as Device or Custom. Click Save to save the settings. Import/Export Person Data Export Person Data You can export added person data for back-up or importing to other devices.
  • Page 44 DS-K3BC430LX Series Swing Gate Figure 7-3 Search Event Enter the search conditions, including the event type, the employee ID, the name, the card No., the start time, and the end time, and click Search. The event types contain access control event and ID card event. If you choose to search for ID card event, you will not need to enter the employee ID, the name, or the card No.
  • Page 45: Configuration

    DS-K3BC430LX Series Swing Gate 7.5 Configuration 7.5.1 View Device Information Click Configuration → System → System Settings → Basic Information to enter the configuration page. You can view the device name, language, model, serial No., version, IO input, IO output, and local RS-485 number.
  • Page 46: Set Dst

    DS-K3BC430LX Series Swing Gate Manual By default, the device time should be synchronized manually. You can set the device time manually or check Sync. with Computer Time to synchronize the device time with the computer's time. Server IP Address/NTP Port/Interval You can set the server IP address, NTP port, and interval.
  • Page 47: View Device Arming/Disarming Information

    DS-K3BC430LX Series Swing Gate 7.5.6 View Device Arming/Disarming Information View device arming type and arming IP address. Go to Configuration → User Management → Arming/Disarming Information . You can view the device arming/disarming information. Click Refresh to refresh the page.
  • Page 48 DS-K3BC430LX Series Swing Gate DNS Server Set the preferred DNS server and the Alternate DNS server according to your actual need. Set Port Parameters Set the HTTP, HTTPS, HTTP Listening parameters. Click Configuration → Network → Network Service → HTTP(S) .
  • Page 49: Event Linkage

    DS-K3BC430LX Series Swing Gate 7.5.8 Event Linkage Set linked actions for events. Steps 1. Click Configuration → Event → Basic Event → Event Linkage to enter the page. Figure 7-7 Event Linkage 2. Set event source. - If you choose Linkage Type as Event Linkage, you need to select event types from the drop- down list.
  • Page 50: Access Control Settings

    DS-K3BC430LX Series Swing Gate Enable Linked Alarm Output, check Alarm Output 1 or Alarm Output 2, and set the alarm output status for the target event. 7.5.9 Access Control Settings Set Authentication Parameters Click Configuration → Access Control → Authentication Settings .
  • Page 51 DS-K3BC430LX Series Swing Gate Select an authentication mode according to your actual needs from the drop-down list. Authentication Interval You can set the authentication interval of the same person when authenticating. The same person can only authenticate once in the configured interval. A second authentication will be failed.
  • Page 52 DS-K3BC430LX Series Swing Gate Open Duration Set the door unlocking duration. If the door is not opened for the set time, the door will be locked. Note The open duration ranges from 5 s to 60 s. Exit Button Type You can set the exit button as Remain Open or Remain Closed according to your actual needs.
  • Page 53 DS-K3BC430LX Series Swing Gate Figure 7-10 Serial Port Settings 2. Set the No., Baud Rate, Data Bit, Stop Bit and Parity. 3. Set the Peripheral Type as Card Reader, Card Receiver, QR Code Scanner or Disable. 4. Set the Peripheral Position as Entrance or Exit.
  • Page 54 DS-K3BC430LX Series Swing Gate Steps Note Some device models do not support this function. Refer to the actual products when configuration. 1. Click Configuration → Access Control → Wiegand Settings . 2. Select Entrance or Exit. 3. Enable Wiegand function.
  • Page 55: Turnstile

    DS-K3BC430LX Series Swing Gate You can enable Verify Credential Locally. After enabling the function, the device will only verify the person's permission without the schedule template, etc. Access Control Mode The device works normally and will verify the person's permission to open the barrier.
  • Page 56 DS-K3BC430LX Series Swing Gate Steps 1. Click Configuration → Turnstile → Keyfob to enter the page. Figure 7-12 keyfob 2. Set Working Mode as One-to-One or One-to-Many. 3. Add keyfob. 1) Click Add and the keyfob adding window will pop up.
  • Page 57 DS-K3BC430LX Series Swing Gate Figure 7-13 People Counting 2. Enable People Counting. 3. EnableDevice Offline People Counting at your actual needs. 4. Select Person Statistics Type as Invalid or Authentication Number. 5. Optional: Click Clear to clear all the people counting information.
  • Page 58 DS-K3BC430LX Series Swing Gate 2. Set Alarm Output Duration. Note The alarm output duration ranges from 0 s to 3599 s. 3. Set Temperature Unit. 4. Drag the block or enter the value to adjust the light board brightness. 5. Set the alarm buzzer beeping duration, door closing delay time.
  • Page 59: Card Settings

    DS-K3BC430LX Series Swing Gate 7.5.11 Card Settings Set Card Security Click Configuration → Card Settings → Card Type to enter the settings page. Set the parameters and click Save. Enable NFC Card Reserved. Enable M1 Card Enable M1 card and authenticating by presenting M1 card is available.
  • Page 60: Set Privacy Parameters

    DS-K3BC430LX Series Swing Gate 7.5.12 Set Privacy Parameters Set the event storage type. Go to Configuration → Security → Privacy Settings The event storage type is overwriting by default. The earliest 5% events will be deleted when the system detects the stored events has been over 95% of the full space.
  • Page 61: Device Debugging

    DS-K3BC430LX Series Swing Gate Import Click and select the file to import. Click Import to start import configuration file. 7.5.14 Device Debugging You can set device debugging parameters. Steps 1. Click Maintenance and Security → Maintenance → Device Debugging .
  • Page 62: Log Query

    DS-K3BC430LX Series Swing Gate You can view the status of the RS-485 card reader and RS-232 card receiver. Movement You can view the working status of motor encoder. Others Passing Mode You can view the entrance and exit mode. Input and Output Status You can view the status of the event input/output, alarm input/output and fire alarm.
  • Page 63 DS-K3BC430LX Series Swing Gate 6. Download the certificate and save it to an asking file in the local computer. 7. Send the asking file to a certification authority for signature. 8. Import the signed certificate. 1) Select a certificate type in the Import Key area, and select a certificate from the local, and click Import.
  • Page 64: Chapter 8 Client Software Configuration

    DS-K3BC430LX Series Swing Gate Chapter 8 Client Software Configuration You can call the hotline to get the iVMS-4200 client software installation package. 8.1 Configuration Flow of Client Software Follow the flow diagram below to configure on the client software. Figure 8-1 Flow Diagram of Configuration on Client Software...
  • Page 65: Device Management

    DS-K3BC430LX Series Swing Gate 8.2 Device Management The client supports managing access control devices and video intercom devices. Example You can control entrance & exit and manage attendance after adding access control devices to the client; you can perform video intercom with the indoor stations and door stations.
  • Page 66 DS-K3BC430LX Series Swing Gate Enter the device password. Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
  • Page 67: Reset Device Password

    DS-K3BC430LX Series Swing Gate 5. Open the exported template file and enter the required information of the devices to be added on the corresponding column. Note For detailed description of the required fields, refer to the introductions in the template.
  • Page 68: Manage Added Devices

    DS-K3BC430LX Series Swing Gate All the online devices sharing the same subnet will be displayed in the list. 3. Select the device from the list and click on the Operation column. 4. Reset the device password. - Click Generate to pop up the QR Code window and click Download to save the QR code to your PC.
  • Page 69: Group Management

    DS-K3BC430LX Series Swing Gate View Online User Click to view the details of online user who access the device, including user name, user type, IP address and login time. Refresh Device Click to refresh and get the latest device information.
  • Page 70: Person Management

    DS-K3BC430LX Series Swing Gate 2. Click Device Management → Group to enter the group management page. 3. Select a group from the group list and select the resource type as Access Point, Alarm Input, Alarm Output, etc. 4. Click Import.
  • Page 71: Import And Export Person Identify Information

    DS-K3BC430LX Series Swing Gate 8.4.2 Import and Export Person Identify Information You can import the information and pictures of multiple persons to the client software in a batch. Meanwhile, you can also export the person information and pictures and save them in your PC.
  • Page 72: Get Person Information From Access Control Device

    DS-K3BC430LX Series Swing Gate 2. Optional: Select an organization in the list. Note All persons' information will be exported if you do not select any organization. 3. Click Export. 4. Enter the super user name and password for verification. The Export panel is displayed.
  • Page 73: Issue Cards To Persons In Batch

    DS-K3BC430LX Series Swing Gate The person information, and the linked cards (if configured), will be imported to the selected organization. 8.4.4 Issue Cards to Persons in Batch The client provides a convenient way to issue cards to multiple persons in a batch.
  • Page 74: Set Card Issuing Parameters

    DS-K3BC430LX Series Swing Gate apply the changes to the device. After applying to device, these changes can take effect on the device. 8.4.6 Set Card Issuing Parameters The client provides two modes for reading a card's number: via card enrollment station or via the card reader of the access control device.
  • Page 75: Configure Schedule And Template

    DS-K3BC430LX Series Swing Gate Remote Mode: Issue Card by Card Reader Select an access control device added in the client and swipe the card on its card reader to read the card number. 8.5 Configure Schedule and Template You can configure the template including holiday and week schedule. After setting the template, you can adopt the configured template to access groups when setting the access groups, so that the access group will take effect in the time durations of the template.
  • Page 76: Add Template

    DS-K3BC430LX Series Swing Gate Move the cursor to the time duration and drag the time duration on the timeline bar to the ● desired position when the cursor turns to Click the time duration and directly edit the start/end time in the appeared dialog.
  • Page 77: Set Access Group To Assign Access Authorization To Persons

    DS-K3BC430LX Series Swing Gate Move the cursor to the time duration and drag the time duration on the timeline bar to the ● desired position when the cursor turns to Click the time duration and directly edit the start/end time in the appeared dialog.
  • Page 78 DS-K3BC430LX Series Swing Gate Note You should configure the template before access group settings. Refer to Configure Schedule and Template for details. 5. In the left list of the Select Person field, select person(s) to assign access authority. 6. In the left list of the Select Access Point field, select door(s), door station(s) or floor(s) for the selected persons to access.
  • Page 79: Configure Advanced Functions

    DS-K3BC430LX Series Swing Gate This operation will not clear the existed access groups of the selected devices and only apply the changed part of the selected access group(s) to the device(s). 4) View the applying status in the Status column or click Applying Status to view all the applied access group(s).
  • Page 80: Configure Device Parameters

    DS-K3BC430LX Series Swing Gate 8.7.1 Configure Device Parameters After adding the access control device, you can configure the parameters of access control device, access control points. Configure Parameters for Access Control Device After adding the access control device, you can configure its parameters, including overlaying user information on picture, uploading pictures after capturing, saving captured pictures, etc.
  • Page 81 DS-K3BC430LX Series Swing Gate Reserved. If enable the function, the device can recognize the ID card. You can present ID card on the device. 4. Click OK. 5. Optional: Click Copy to, and then select the access control device(s) to copy the parameters in the page to the selected device(s).
  • Page 82 DS-K3BC430LX Series Swing Gate Configure Parameters for Card Reader After adding the access control device, you can configure its card reader parameters. Before You Start Add access control device to the client. Steps 1. Click Access Control → Advanced Function → Device Parameter .
  • Page 83 DS-K3BC430LX Series Swing Gate Steps 1. Click Access Control → Advanced Function → Device Parameter to enter access control parameter configuration page. 2. In the device list on the left, click to expand the door, select an alarm input and you can edit the alarm input's parameters on the right.
  • Page 84: Configure Device Parameters

    DS-K3BC430LX Series Swing Gate Temperature Unit Select the temperature unit that displayed in the device status. Lightboard Brightness Adjust the brightness of the device light. Barrier Material Select the material of the barrier gate. You can select the barrier material from the drop- down list.
  • Page 85 DS-K3BC430LX Series Swing Gate Set Wiegand Parameters You can set the access control device's Wiegand channel and the communication mode. After setting the Wiegand parameters, the device can connect to Wiegand card reader via Wiegand communication. Before You Start Add access control device to the client, and make sure the device supports Wiegand.
  • Page 86: Door/Elevator Control

    DS-K3BC430LX Series Swing Gate 8.8 Door/Elevator Control In Monitoring module, you can view the real-time status of the doors or elevators managed by the added access control device. You can also control the doors and elevators such as open/close the door, or remain the door open/closed via the client remotely.
  • Page 87: Check Real-Time Access Records

    DS-K3BC430LX Series Swing Gate Remain Unlocked The door will be unlocked (no matter closed or open). All the persons can access the door with no credentials required. Remain Locked The door will be closed and locked. No person can access the door even if he/she has the authorized credentials, except the super users.
  • Page 88 DS-K3BC430LX Series Swing Gate Steps 1. Click Monitoring to enter monitoring module. Real-time access records are displayed on the bottom of the page. You can view record details Note You can right click the column name of access event table to show or hide the column according to actual needs.
  • Page 89: Appendix A. Dip Switch

    DS-K3BC430LX Series Swing Gate Appendix A. DIP Switch A.1 DIP Switch Description The DIP switch is on the access control board. No.1 and No 2 is from the low bit to the high bit. Figure A-1 DIP Switch When the switch is towards ON, it means the switch is enabled, otherwise, the switch is off.
  • Page 90: Appendix B. Button Configuration Description

    DS-K3BC430LX Series Swing Gate Appendix B. Button Configuration Description Refer to the table below for device configuration via button on the lane control board. Level-1 Configuration Description Level-2 Configuration Notes No. and Functions Study Mode 1-Exit Study Mode/ Normal Mode...
  • Page 91 DS-K3BC430LX Series Swing Gate Level-1 Configuration Description Level-2 Configuration Notes No. and Functions 14-Entrance prohibited; exit remaining open 16-Entrance remaining open; exit under control 18-Entrance remaining open; exit remaining open 20-Entrance remaining open; exit prohibited Memory Mode 1-Disable 2-Enable Note...
  • Page 92 DS-K3BC430LX Series Swing Gate Level-1 Configuration Description Level-2 Configuration Notes No. and Functions Note By default, 5 will be displayed on the display screen. Card Reading on the 1-Do not open Alarm Area 2-Open Note By default, 2 will be displayed on the display screen.
  • Page 93 DS-K3BC430LX Series Swing Gate Level-1 Configuration Description Level-2 Configuration Notes No. and Functions Note By default, 1 will be displayed on the display screen. Barrier Length 1-550 2-600 3-650 4-700 5-750 6-800 7-850 8-900 9-950 10-1000 11-1100 12-1200 13-1300 14-1400...
  • Page 94 DS-K3BC430LX Series Swing Gate Level-1 Configuration Description Level-2 Configuration Notes No. and Functions Brightness of Light 0-0,1-1,2-2, … , 10- The higher the value is, the brighter the light will be. Note By default, 3 will be displayed on the display screen.
  • Page 95 DS-K3BC430LX Series Swing Gate Level-1 Configuration Description Level-2 Configuration Notes No. and Functions Brake 1-Disable 2-Barrier Position Exception 3-Intrusion Note By default, 2 will be displayed on the display screen. Brake Angle 1-5° 2-10° 3-15° Note By default, 1 will be displayed on the display screen.
  • Page 96 DS-K3BC430LX Series Swing Gate Level-1 Configuration Description Level-2 Configuration Notes No. and Functions Main Lane or Sub Lane 1-Main Lane 2-Sub Lane Note By default, 1 will be displayed on the display screen. Combination Mode 1-Main and Sub Lane 2-Single Main Lane...
  • Page 97 DS-K3BC430LX Series Swing Gate Level-1 Configuration Description Level-2 Configuration Notes No. and Functions Note By default, 1 will be displayed on the display screen. Note When the Configuration No. 50 and 51 are adjusted, you need to reboot the device manually.
  • Page 98 DS-K3BC430LX Series Swing Gate Appendix C. Event and Alarm Type Event Alarm Type Passing Timeout None Barrier Obstructed None...
  • Page 99 DS-K3BC430LX Series Swing Gate Appendix D. Table of Audio Index Related Content Index Content Authenticated. Card No. does not exist. Passing timeout. No permissions. Authentication time out. Authentication failed. Expired card.
  • Page 100 DS-K3BC430LX Series Swing Gate Appendix E. Error Code Description The swing gate will display the error code on the seven-segment display if error occurred. Refer to the table below to find the description of each number. Error Reason Code Error Reason...