Mounting Hole Specifications; Grounding Instructions; Precautions For Installation - Qlightec SESA-TI Quick Start Manual

Explosion proof warning light/ signal light and electric horn combinations(telephone initiated)
Table of Contents

Advertisement

Mounting Hole Specifications

• Machine holes on the mounting surface referring to
the diagram below.
4-Ø9 HOLES
Bulb/ Xenon Bulb Replacement Instructions
■ Bulb Replacement Instructions(SESA only)
Assemble bulb
• Please wait at least 1 minute after turning off the power
before replacing the bulb.
• In order to dissemble the bulb, please push down the bulb( ① )
lightly and screw it counterclockwise.
• In order to put the bulb in to the unit, please place the bulb( ① )
in the socket( ② ) and screw it clockwise while lightly pushing
down the bulb.

Precautions for installation

• In case of outdoor applications, install the product in the upright
position. Do not install the product horizontal or upside-down
positions where water can potentially penetrate into the product
and impact it's operation.
Installation Environment and Protection Rating
• This product is designed to be explosion proof.
• Please make sure to use the product in an environment that meets the specified explosion proof rating and regulations.
• For further information, please visit our website (www.qlight.com).
Disassemble bulb

Grounding Instructions

Please use an M4 bolt at the location marked in the diagram
above to ground the product.
When connecting the grounding cable, please use a ring terminal.
• Please use a grounding cable with a diameter greater than 4mm.
■ Xenon Bulb Replacement Instructions(SESAS only)
Disassemble bulb
• Please wait at least 30 minutes after turning off the power before
replacing the xenon bulb.
• Please pull out the entire xenon bulb structure ① to disassemble
while pushing the hook down.
• For xenon bulb assembly, please push down the connector
portion of the xenon bulb structure to the connector pin
location ② until it makes "clark" sound.
Left direction
Reverse direction
5
M4 ground contact part
Assemble bulb
Right direction
WALL