Summary of Contents for A.J.Antunes vizion VZN V Series
Page 1
MANUFACTURING NUMBERS: 9700741 9700751 VZN V SERIES WATER FILTRATION System Tested and Certified by NSF International and WQA against NSF/ANSI VZN-441V, VZN-441V-T5 Standard 42 and 53 for the reduction of: Standard No. 42: Aesthetic Effects Nominal Particulate Reduction Class I Standard No.
VZN V SERIES TABLE OF CONTENTS Owner Information ...............2 System Inlet Connection ..........12 General................2 Filtered Water Permeate Outlet Connection ....12 Warranty Information ............2 Inlet Water Plumbing ............12 Service/Technical Assistance ..........3 Installing a Bypass ............13 Important Safety Information ..........4 Starting the Controller ............
VZN V SERIES OWNER INFORMATION (continued) Service/Technical Assistance Suggested replacement period for the Ultra Filter Cartridge is If you experience any problems with the installation or opera- approximately 3 years. tion of your system, contact A.J. Antunes & Co. at 1-630-784- 1000, or toll free in the United States at 1-800-253-2991.
VZN V SERIES IMPORTANT SAFETY INFORMATION In addition to the warnings and cautions in this manual, use The following warnings and cautions appear throughout this the following guidelines to safely operate the system: manual and should be carefully observed. • Read all instructions before using equipment. •...
Page 5
VZN V SERIES IMPORTANT SAFETY INFORMATION (continued) Protect from becoming dry CAUTION If the membrane dries out, irreversible damage to the Ultra This equipment is to be installed to comply with the Filter membrane may result. Protect the filter from becoming basic plumbing code of the Building Officials and Code dry by keeping it wet and sealed at all times.
VZN V SERIES OPERATION Overview The VZN system operates in two modes: System Flush • Normal Operation Mode Solenoid Valve (Automatic) • Flush Mode Rinse Ball Valve During Normal Operation Mode, water enters the Inlet and (Manual) flows through the Ultra Filter before exiting the Permeate Outlet as usable product water.
VZN V SERIES INSTALLATION Unpacking Equipment Setup 1. Open the large box. It should contain: GENERAL A. Plate-mounted VZN system with Ultra Filter When placing the system into service, pay attention to the Cartridge installed following guidelines: B. Padded envelope containing: •...
VZN V SERIES INSTALLATION (continued) CAUTION Back Plate The system is (holes along bottom designed to hang from Due to its weight and size, the VZN system MUST be for additional the Mounting Bracket. mounted with the provided Mounting Bracket. Read mounting stability) the Mounting the System section before attempting to mount the VZN system.
VZN V SERIES INSTALLATION (continued) Drain Valve Connection The drain is for flushing particle buildup out of the Example Drain Valve Connection system during self cleaning. 1. Cut a length of tubing (not supplied) so it reaches the Secure Hose drain from the Drain Valve.
VZN V SERIES INSTALLATION (continued) Rinse Valve Connection 1. Obtain a length of 3/4” garden hose long enough to reach from the Rinse Valve to the drain. 2. Install a gasket in the end of the hose (non-drain end). 3. Connect the hose to the Rinse Valve fitting. Use a back- up wrench on the fitting if required (Figure 5).
VZN V SERIES INSTALLATION (continued) Rinsing the Ultra Filter Cartridge The Ultra Filter Cartridge comes pre-installed in the VZN system. The Ultra Filter Cartridge must be rinsed before the system is used to remove any air and protective solution. NOTE: Ultra Filter Cartridge must be rinsed to drain Outlet Ball Valve before use.
VZN V SERIES INSTALLATION (continued) Sanitizing the System and Lines Rinsing the Carbon Element and TAC Cartridge The plumbing must be sanitized to eliminate possible contam- The Carbon Element and TAC Cartridge MUST be rinsed ination that may have occurred during the installation process. before using the system the first time and immediately after the Carbon Element or TAC Cartridge have been replaced.
VZN V SERIES MAINTENANCE Replacing the Ultra Filter Cartridge NOTE: Always install new Carbon Element and new Snap Ring TAC Cartridge Element after replacing the Ultra Filter Cartridge. 1. Turn off water to the system by closing the Inlet Ball End Cap Valve and Outlet Ball Valve.
VZN V SERIES MAINTENANCE (continued) Rinsing and Replacing the Carbon Element RED Pressure O-Ring NOTE: Remove the TAC Cartridge Element, if present, Relief Button and re-attach the TAC Housing before proceeding. Carbon Element 1. Turn off the water to the system by closing the Inlet Ball Head Valve and Outlet Ball Valve.
VZN V SERIES MAINTENANCE (continued) Rinsing and Replacing the TAC Cartridge (VZN-441V-T5 ONLY) bon Element installed. 1. Turn off water to the system by closing the Inlet Ball Valve and then close the Outlet Ball Valve. 2. Press the FLUSH button to initiate the flush cycle. Repeat several times to ensure the permeate tank is empty.
VZN V SERIES MAINTENANCE (continued) Changing the Interval Setting Resetting the Timer Program During the normal operation, the system will flush accord- CAUTION ing to the set interval. It is possible the system will flush at a Changing the flush interval may cause the Ultra Filter time of high water use.
VZN V SERIES TROUBLESHOOTING Problem Possible Cause Corrective Action The power cord is not plugged into the Plug power cord into the appropriate outlet. appropriate outlet or control box. The unit is plugged into a switched Plug the power cord into an unswitched outlet. Unit does not have power.
VZN V SERIES REPLACEMENT PARTS VZN-441V Systems P/N 1011079 Rev. J 01/14...
Page 21
VZN V SERIES REPLACEMENT PARTS (continued) VZN-441V-T5 Systems P/N 1011079 Rev. J 01/14...
Page 22
VZN V SERIES REPLACEMENT PARTS (continued) Replacement Parts can be purchased from an authorized dealer. Contact A.J. Antunes & Co. at 1-630-754-1000 or toll free in the United States at 1-800-253-2991. VZN-441V Systems Item Part Description Qty. Item Part Description Qty.
LIMITED WARRANTY Equipment manufactured by A.J. Antunes & Co. has been constructed of the finest materials available and manu- factured to high quality standards. These units are warranted to be free from defects in materials and workman- ship for a period of two years from date of purchase under normal use and service, and when installed in accor- dance with manufacturer’s recommendations*.