Wireless Temperature Configuration Options - DSC iotega WS901 Reference Manual

Wireless security and automation system
Hide thumbs Also See for iotega WS901:
Table of Contents

Advertisement

wireless device on the alarm system.
Default:
Valid range:
8.12 Wireless Temperature Con-
figuration Options
The following sections are used for programming wireless
temperature sensors.
Note: Wireless temperature feature was not evaluated by
UL/ULC.
Device Enable/Disable
This option is used to enable and disable the wireless
device.
Default:
Valid range:
Device Partition Assignment
This option is used to enable and disable the wireless
device.
Default:
Valid range:
Chime Tone
This option is used to select the tone emitted by the device
when the zone is tripped.
Default:
Disabled
Valid range:
Beeps, Bing Bing, Ding Dong, Alarm Tone
Zone Type
This option is used to program a zone type for the device.
Default:
24-hour Temperature
Valid range:
24-hour Temperature
Device Label
This option is used to program a custom label for the wire-
less device.
Default:
Zone ZZZ
Valid range:
32 character ASCII
Zone Attribute
This section is used to customize zone behavior for the
device. The table below specifies the status of each attribute
Enabled
Enabled/Disabled
Enabled
Enabled/Disabled
Enabled
1
for this device.
See "Available Zone Attributes" on page 45 for attribute
definitions.
Door Chime
Alarm Report
Burglary Verified
Transmission Delay
Bell Audible
Bell Steady
Bypass Enable
Force Arm
Swinger Shutdown
Two Way Audio
Talk Listen
Supervision
This option is used to enable/disable wireless supervision of
the device. Supervision monitors the presence of the wire-
less device on the alarm system.
Default:
Valid range:
Temperature Format
This section is used to select the scale temperature is dis-
played in.
Default:
F
Valid range:
F (Fahrenheit), C (Celsius)
High Temperature Warning
This option is used to set the temperature threshold for activ-
ating the High Temperature warning indicator. A high tem-
perature warning sounds an audible alert but does not
send a trouble to the central monitoring station.
This option is disabled by entering -999 or 999.
Default:
Valid range:
High Temperature Alarm
This option is used to set the temperature threshold for activ-
ating the High Temperature alarm.
This option is disabled by entering -999 or 999.
Default:
Valid range:
- 37 -
Disabled
Enabled
Disabled
Enabled
Enabled (read-only)
Enabled (read-only)
Enabled (read-only)
Disabled (read-only)
Disabled (read-only)
Disabled (read-only)
Disabled (read-only)
Enabled
Enabled/Disabled
999
-999 to 999
999
-999 to 999