Download Print this page

LG MULTI V SE Series Installation Manual page 11

Heat pump indoor unit
Hide thumbs Also See for MULTI V SE Series:

Advertisement

Bundle the piping and drain hose together by
wrapping them with cloth tape over the range
within which they fit into the rear piping housing
section.
Drain hose
8. Reroute the pipings and the drain hose across
the back of the chassis.
Piping for
passage through
piping hole
9. Set the pipings and the drain hose to the back of
the chassis with the tubing holder.
Hook the edge of tubing holder to tap on chassis
and push the bottom of tubing holder to be
engaged at the bottom of chassis.
10. Indoor unit installation
Remove the spacer.
Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
Press the lower left and right sides of the unit
against the installation plate until the hooks engage
into their slots(clicking sound).
Pipe
Vinyl tape
(narrow)
Wrap with
vinyl tape(wide)
Tubing holder
Connecting
cable
Drain hose
CAUTION
Installation Information (For left piping)
• Good case
For left piping. Follow the instruction below.
Press on the upper side of clamp. ( )
Unfold the tubing to downward slowly. ( )
Installation Manual 11