Download Print this page

Qlightec SEA Quick Start Manual

Explosion proof warning light/ signal light

Advertisement

Quick Links

Explosion Proof Warning Light/ Signal Light
SEA/ SEAL/ SEALR/ SEAS
40
60
40
55
Ex
66
Thank you for purchasing Qlight's products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Safety Precautions for Explosion Proof Products
Please follow the instruction below to ensure safe and correct use of explosion proof products.
1. Explosion proof products should be managed according to explosion proof regulations. Do not disassemble, assemble, alter or repair
the product arbitrarily.
2. The temperature rating of the product is the temperature the product will experience at the applied rated voltage and ambient
temperature indicated.
3. Use cable glands that satisfy the product's explosion proof grade and temperature grade.
4. Unused cable entries must be filled with material that meets the explosion proof grade and temperature rating.
5. Before installing the product, please make sure all cautions indicated on the labels, packaging, and operation manual of the product
are fully understood.
6. Installation, maintenance and repair of the product must be performed by experts in the explosion proof field, or persons who have
received relevant training.
7. For safety, the product should be installed and operated in environments that avoid high temperature and high pressure.
8. Please follow general safety precautions and avoid installing the product in locations that may generate excessive heat.
9. When installing the product in places where chemicals are located, please make sure that the environment does not have two or more
incompatible chemicals mixed. For safety, please read the instruction manual carefully and be mindful of the chemical compositions
where the product is used.
10. This product requires grounding.
11. Please note that special conditions shall be applied if the sign "X" is placed after the certificate number.
1) For safe use, regular overpressure test must be carried out in accordance with EN 60079-1, clause 15.2.3.
2) For safe use, tempered glass must be protected from strong impact
Precaution for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point.
(Failure to follow these instructions may lead to fire, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device.
(Failure to follow this may cause damage to property, fire, electric shock and loss of life.)
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product
that would void the warranty.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn off the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product's specification.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.
Ordering Specifications
SEA
-
220
[Model number]
[Voltage]
|
|
• SEA
• 12-DC12V
• SEAS
• 24-DC24V
• SEAL
• 110-AC110V
• SEALR
• 220-AC220V
-
R
[Color]
|
R-Red
A-Amber
G-Green
B-Blue
1
Please scan the QR code for more
detailed product information.
www.qlight.com

Advertisement

loading

Summary of Contents for Qlightec SEA

  • Page 1 Explosion Proof Warning Light/ Signal Light SEA/ SEAL/ SEALR/ SEAS Thank you for purchasing Qlight’s products. Please read this user manual carefully prior to installation and operation to ensure safe and correct use. Safety Precautions for Explosion Proof Products Please follow the instruction below to ensure safe and correct use of explosion proof products.
  • Page 2: Product Specifications

    0.022A Ø167 R-Red A-Amber DC12V 0.183A G-Green 5.33kg B-Blue DC24V 0.127A SEALR AC110V 0.035A 5.74kg AC220V 0.017A Dimensions (Units : mm) SEA/ SEAL/ SEALR/ SEAS Ø167 CABLE ENTRY 1/2'' NPT 4-Ø8.5 FITTING HOLES CABLE ENTRY 1/2'' NPT 4-Ø8.5 FITTING HOLES...
  • Page 3: Mounting Hole Specifications

    Terminal Box Wiring Instructions • Terminal block is located inside of the product. Unscrew the 4 bolts located in the upper body to get rid of the upper lighting element of the unit. • Please apply fork (U-type) or ring (O-type) locking spade terminal at naked tip of the wire for secure connection.
  • Page 4 Bulb Replacement Instructions/ Xenon Bulb Replacement lnstructions ■ Bulb Replacement Instructions(SEA only) ■ Xenon Bulb Replacement Instructions(SEAS only) ① ① Disassemble Assemble Assemble xenon bulb xenon bulb bulb ② ② Disassemble bulb • Please wait at least 1 minute after turning off the power •...
  • Page 5 Product installation direction ■ Install the product in accordance with the manual. Otherwise rainwater or moisture may penetrate into the product. ㆍBEACON/SIGNALING LIGHT ※ For products with a protection rating of less than IPX4, please install it vertically. Power cord inlet part shall not be facing the sky. ㆍ...
  • Page 6 MEMO...
  • Page 7 MEMO...
  • Page 8 RELIABILITY, FUNCTION OR DESIGN OR OTHERWISEA. Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, SEAoul, Korea (Postal Code : 08507) Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea (Postal Code : 50805) www.qlight.com EN - SEA - 2301A...

This manual is also suitable for:

SealSealrSeas