Download Print this page

Pickering 60-103D Quick Start Manual

Lxi/usb 18-slot modular chassis

Advertisement

Quick Links

LXI/USB 18-Slot Modular Chassis
y Gigabit Ethernet Interface
y USB3 Control
y Accepts More Than 1000 Pickering Interfaces
PXI 3U Switch and Simulation Modules
y Accepts most Pickering Interfaces 3U
PXI Instrumentation Modules
y Applications From Simple Switching
to RF, Microwave and Optical
y Front Panel IP Address Display
y Sequence Service & Triggering Option
y Low Audible Operating Noise
y 3 Year Warranty
The 60-103D is compliant with the LXI Standard 1.4 and supports
Pickering Interfaces 3U PXI switching and simulation modules
as though they are an LXI compliant device, complete with a
driverless soft front panel. The 60-103D supports up to 18 off 3U
modules and is equivalent to a 19 slot PXI chassis.
The chassis allows all switching and simulation 3U PXI modules
from Pickering and most† instrumentation products (such as
digital I/O, attenuators, power supplies) to be installed and
controlled. It is supplied with a built-in generic IVI driver to
control the modules in accordance with the LXI specification, but
can also be controlled through a kernel driver.
Modules available for installation cover a large variety of
functions including switches, matrices and multiplexers capable
of switching µA up to 40A. RF, microwave and optical switches
are supported as well as some instrument functions such as
variable resistor modules. For more information on compatible
PXI modules, please refer to the 60-103D User Manual.
The Ethernet interface enables the chassis to be controlled
through a LAN connection with a front panel display showing the
IP address. The chassis allows the remote operation of switching
modules over long distances including world wide networks. The
separation of the chassis from the controller's PCI bus simplifies
power-on sequencing of systems and provides independence
from the migration of the Windows and VISA environment.
Control
via
Ethernet
or USB
Control Computer
Triggering I/O
(60-103D-002 only)
Plugging Pickering Interfaces PXI modules into the 60-103D LXI/USB Modular Chassis provides an LXI
compliant switching platform. A simple Ethernet lead is the only physical control connection required.
LAN
Interface
1
2
USB
Interface
Embedded
Controller
Scan List
Sequencing
& Triggering
(60-103D
-002 only)
PCI
Interface
Pickering's Range of PXI & PXIe Chassis
Chassis Type
PXI
PXI
PXI
PXI
PXIe Hybrid (Gen 3)
PXIe Hybrid (Gen 3)
PXIe Hybrid (Gen 2)
PXI with LXI/USB Control*
PXI with LXI/USB Control*
PXI with LXI/USB Control
PXI with LXI/USB Control
PXI with LXI/USB Control*
*Includes Scan List Sequencing and optional Triggering function.
The compact 4U height of the 60-103D allows efficient use of rack
space. Three fans ensure maximum module cooling and an efficient
direct convection design allows operation over an extended
temperature range.
The 60-103D can be configured over its LXI compliant interface
using any standard web browser. The interface can be used to load
soft front panels for the installed modules, so they can be manually
accessed without the need for drivers on the controller.
† For compatibility of Pickering's PXI modules other than switching
or simulation functions, please check the module's data sheet.
Note: This product has been introduced as a "form & fit" update
to the 60-103B, the electrical performance and software are the
same. The 60-103D has the added features of a USB interface and
Sequence Service & Triggering.
3U PXI Modules
3
4
5
6
7
8
9
10 11
12
cPCI
Backplane
60-103D
Slots
Chassis Size
Model No.
8
4U Full Rack
40-908
14
4U Full Rack
40-914
19
4U Full Rack
40-923A
8
4U Half Rack
40-924
8
4U Half Rack
42-924
18
4U Full Rack
42-925
18
4U Full Rack
42-926
7
4U Half Rack
60-102D
18
4U Full Rack
60-103D
2
1U Half Rack
60-104
4
2U Half Rack
60-105
6
1U Full Rack
60-106
60-103D
Chassis
13
14 15 16 17
18
Power
Supply
pickeringtest.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the 60-103D and is the answer not in the manual?

Questions and answers

Ondre Chester
July 31, 2025

Curious to know what Phase this part would have (Phase X, Y, or Z). As well if its a single or etc? IF I'm not making myself clear I apologize feel free to ask me clarifying questions.

Subscribe to Our Youtube Channel

Summary of Contents for Pickering 60-103D

  • Page 1 Triggering I/O (60-103D Power (60-103D-002 only) -002 only) Supply cPCI Interface Backplane Plugging Pickering Interfaces PXI modules into the 60-103D LXI/USB Modular Chassis provides an LXI compliant switching platform. A simple Ethernet lead is the only physical control connection required. pickeringtest.com...
  • Page 2 Example home page for a Modular Chassis - provides fast access to configuration information for the chassis through any web browser. Example General Soft Front Panel - The 60-103D provides soft front panels to enable manual operation of PXI modules.
  • Page 3: Specifications

    These sequences can be triggered by software trigger, local bus support (subject to module support). or - for the 60-103D-002 - by one of the sixteen software configurable open collector triggers. Chassis Capacity: 18 off 3U user slots available.
  • Page 4: Specifications & Ordering Information

    Optional 19” rack mounting hardware* 63-103-001 Height: 178 mm (7.01”) Depth: 455 mm (17.91”) * Please refer to the 60-103D User Manual for information For rack mounting, on the optional chassis mounting hardware. recommended to be mounted in 5U to allow free bottom intake of air.
  • Page 5 To learn more, please go to: pickeringrelay.com Programming Pickering provide kernel, IVI and VISA (NI & Keysight) drivers which are compatible with all Microsoft supported versions of Windows and popular older versions. For a list of all supporting operating systems, please see: pickeringtest.com/os The VISA driver support is provided for LabVIEW Real Time Operating Systems (Pharlap and Linux-RT).
  • Page 6 Three Year Warranty & Guaranteed Long-Term Support All standard products manufactured by Pickering Interfaces are warranted against defective materials and workmanship for a period of three years from the date of delivery to the original purchaser. Extended warranty and service agreements are available for all our modules and systems with various levels to suit your requirements.