Weiterentwicklung im Sinne des Fortschrittes behalten wir uns vor. - Technical Modifications are subject to change. - Details techniques subject à modification sans avis préalable
Translation of the original operation manual GB, Stand 08 / 2019
Page 1
E N V I R O N M E N T A L L Y E F F E C T I V E S E C U R E ABS 200 A-PKW # 28 278 ABS 200 Z-PKW # 28 228 ABS 200 A-PKW Weiterentwicklung im Sinne des Fortschrittes behalten wir uns vor.
· Please observe: This operation manual contains all necessary information. Please read carefully to avoid damages and faults. All Rapid pieces of equipment are checked carefully before delivery for their perfect composition and function. In case of improper use all rights to claim under guarantee are void.
+49 (6158) 92980-0 2. Operating conditions 2.1 Environmental conditions TEMPERATURE: Min. -10°C(14°F) / Max. +60°C(140°F) RELATIVE HUMIDITY: Max. 90% ATTENTION! THE MOTORS ARE NOT OF AN ANTI-EXPLOSIVE TYPE. ATTENTION! It is the installer’s responsibility to use tubing with adequate characteristics. ATTENTION! The temperature limits shown apply to the pump components and must be respected to avoid possible damage or malfunction.
Motor: Asynchronous motor, single-phase, 2 pole, closed type (protection class IP55 in conformance with EN 60034-5-86 regulations), self-ventilated. Item No. Pump model Nozzle Flow meter 28 278 ABS 200 A-PKW auto 5. Assembling / Installation 4x f 2x g 1x a2 ISO 7380...
+49 (6158) 92980-0 8. Maintenance and trouble shooting Problem Possible cause Correct iv act ion low or no ow rate low level in the suction tank rell the tank filter clogged clean the filter excessive suction pressure lower the pump with respect to the level of the tank or increase the cross- section of the tubing high loss of head in the delivery...
Page 12
+49 (6158) 92980-0 www.rapid-group.de• F a x : + 4 9 ( 6 1 5 8 ) 9 2 9 8 0 - 5 0 • info@rapid-group.de Rapid Group GmbH• Bahnhofstraße 53-55• 64560 Riedstadt• Telefon:+49 (6158) 92980-0•...