Step 1C – Press NEXT and ▼ simultaneously for 3 seconds and release. Then press
STEP 1C
NEXT and ▼ simultaneously for 3 seconds and release. If screen in Step 2C does not
appear in 5 seconds the lock on the valve is activated. To unlock press ▼ NEXT, ▲, and
CLOCK in sequence, then press NEXT and ▼ simultaneously for 3 seconds and release.
Then press NEXT and ▼ simultaneously for 3 seconds and release.
STEP 2C
STEP 3C
SET
STEP 4C
SET
STEP 5C
SET

Cycle Sequence

Step 2C – Use ▲ or ▼ to select 1.0 for 1" valve, 1.25 for 1.25" valve, 1.5 for 1.5" valve,
2.0 for 2" valve, or 1.0T for twin valve.
(SET TO 1.0)
Press NEXT to go to next Step. Press REGEN to return to exit Cycle Sequence.
Step 3C – When 1.5 or 2.0 are selected, an additional screen will appear. It is used to
select which size flow meter is to be used with the valve, 1.5", 2.0", 3.0", 1.0r or PUL
(Variable Meter Calibration.) Variable meter pulses of 0.1-150.0 PPG can be selected.
(N/A)
If Step 2C is set to 1.0, Step 3C will not be displayed.
SET
SET
Step 5C – dp Select OFF using the ▲ or ▼:
(SET TO oFF)
Press NEXT to go to Step 6C. Press REGEN to return to previous step.
Step 4C – Allows selection of one of the following using the ▲
or ▼, buttons:
• the Control Valve to act as an alternator; or
• the Control Valve to have a no hard water bypass: or
• the Control Valve to have a Separate Source during the
regeneration cycle; or
• the Control Valve to operate with the System Controller.
Select OFF when none of these features are used.
(SET TO oFF)
Press NEXT to go to Step 5C. Press REGEN to return to exit
Cycle Sequence.