Download Print this page

Britex UREG Installation Manual

Regency urinal

Advertisement

Quick Links

UREG
Regency
Urinal
Installation
Guide
MELBOURNE
SYDNEY
Britex Place Mirra Crt
16 Northumberland Drv
Bundoora VIC 3083
Taren Point NSW 2229
t (03) 9466 9000
t (02) 9531 2100
e vic@britex.com.au
e nsw@britex.com.au
PERTH
BRISBANE
Unit 1/8 Principal Link
19 Manilla St
Malaga WA 6090
East Brisbane QLD 4169
t (08) 9249 5464
t (07) 3363 2400
e wa@britex.com.au
e qld@britex.com.au
UREG Installation Guide | QID 1.21 | Rev 3 | 29 May 2023
ADELAIDE
The Britex Group
SA State Office
t 1300 764 744
e sa@britex.com.au
URE
TITLE:
ISO

Advertisement

loading
Need help?

Need help?

Do you have a question about the UREG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Britex UREG

  • Page 1 (02) 9531 2100 t (08) 9249 5464 t (07) 3363 2400 t 1300 764 744 e vic@britex.com.au e nsw@britex.com.au e wa@britex.com.au e qld@britex.com.au e sa@britex.com.au UREG Installation Guide | QID 1.21 | Rev 3 | 29 May 2023 TITLE:...
  • Page 2 Preparation and Completion Notes Britex urinals are approved for use as per the accompanying certifications and can be coupled with cisterns, flush valves & sensor flushing systems according to specific model requirements. It is the installer’s responsibility to ensure that the urinal is installed in accordance and to the regulations...
  • Page 3 Up to Up to Up to lenoid Up Solenoid Length - 1800mm- 1800mm- 1800mm 1800mm 1800mm to 1800mm 1800mm 3600mm 3600mm UREG Australia’s Finest Stainless | britex.com. UREG Installation Guide | QID 1.21 | Rev 3 | 29 May 2023...
  • Page 4 Rear of Urinal 1.6mm SS Angle Legs Spaced along Front and Rear of Gutter 305 Standard 220 Min - 485 Max mended Australia’s Finest Stainless | britex.com. UREG Installation Guide | QID 1.21 | Rev 3 | 29 May 2023...
  • Page 5: Installation Instructions

    The urinal must be fully supported to alleviate any flexing. No air pockets should be present. d. Weighted timbers can be placed within the trough to maintain the formation of the trough. Australia’s Finest Stainless | britex.com. UREG Installation Guide | QID 1.21 | Rev 3 | 29 May 2023...
  • Page 6 DO NOT SCALE DRAWING SHEET 2 OF 3 SCALE:1:20 britex.com.au info@britex.com.au DIMENSIONS ARE IN MILLIMETERS Australia’s Finest Stainless | britex.com. UREG Installation Guide | QID 1.21 | Rev 3 | 29 May 2023 UREG TITLE: DATE 25/05/23 Install Steps DRAWN...
  • Page 7 Urinal Foot Trench Depth Model Print Dimensions < 1M - 5M Long L + 40 x W UREG L x W 610 Australia’s Finest Stainless | britex.com. UREG Installation Guide | QID 1.21 | Rev 3 | 29 May 2023...
  • Page 8 Flush Pipe Flush Pipe 40mm BSP Thread 40mm BSP Thread 105 ±3 105 ±3 105 ±3 105 ±3 (Nut Removed) (Nut Removed) Australia’s Finest Stainless | britex.com. UREG Installation Guide | QID 1.21 | Rev 3 | 29 May 2023...
  • Page 9: Spare Parts

    Spare Parts 72-05-0010 Spring Loaded Urinal Outlet Cover Australia’s Finest Stainless | britex.com. UREG Installation Guide | QID 1.21 | Rev 3 | 29 May 2023...
  • Page 10: Care And Maintenance

    Once all dirt, oil and grime is removed, rinse thoroughly with Australia’s Finest Stainless | britex.com. UREG Installation Guide | QID 1.21 | Rev 3 | 29 May 2023...
  • Page 11: Warranty

    BRITEX at no charge, provided that the terms of the manufacturer’s warranty are followed. This warranty is the only warranty given by BRITEX, and we expressly disclaim all other warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose.