Operation Mode

There are two modes "Test" and "Normal".
"Test Mode" is for the user test the sensor function when installation.
"Normal Mode" for the normal operation.
When the event triggered, normally the LED won't indicated, unless the
battery is in the low level, the LED will flash once. But in the "Test
Mode" the LED also will light ON one second.
When the event triggered, the device will report the messages to the
nodes in the group 1. The messages also include the battery level, the
temperature and the illumination level. The user can switch the report
by setting the configuration NO. 5 bit4 (illumination) and bit5
(temperature), and the configuration NO. 7 bit6 (battery).
When the event triggered, if the environment luminance is less than
the setting of the value of the configuration NO. 4, the device will emit
the signal to turn ON the lighting equipment, those nodes are in the
group 2. And delay a while to turn OFF the lighting equipment. The
delay time is setting by the configuration NO. 9.
The PIR motion re-detected interval, in the "Test Mode" fixed to 6
seconds. In the "Normal Mode", it according to the setting of the
All manuals and user guides at all-guides.com
configuration NO. 8.
Notice: When the tamper key of the back side is released, the device
always in the "Test Mode", no matter the DIP switch setting.

Battery Installation

When the device report the low battery message. The user should
replace the battery to new one. The battery type is CR123A, 3.0V.
The way to open the front cover please follow below steps.
Replace the new battery and install the cover back.

Choosing a Suitable Location

Installation
1. In the first time, add the device into the Z-Wave
make sure the primary controller is in the inclusion mode. And then
power on the device, just take out the insulation Mylar in the back side
4
1. Using a tool to press the 1-1 position, to release the cover.
2. Hold the front cover and pull back
3. Hold the front cover and pull up
1. Put the front cover bottom to 1-1, and press down.
2. Push the front cover top to 2-1.
1. The recommended mounting height is 160cm
2. Don't let the device facing the window or the sunlight.
3. Don't let the device facing the source of heat. For instance the
heater or the air-condition.