Power Up Procedure; Security Network - D-Link DCH-122 Manual

Pir motion sensor
Table of Contents

Advertisement

* Tamper Report:
Both the 2 tamper keys are pressed over 5 seconds. The device will
into the alarm state. In that state, if any one of the tamper keys be
released, the device will unsolicited to send the report to the nodes in
the group 1.
Notification Report (V4)
Notification Type: Home Security (0x07)
Event: Tampering. Product covering removed (0x03)
Sensor Binary Report (V2)
Sensor Type: Tamper (0x08)
Sensor Value: 0xFF
* Temperature Report:
When the PIR motion detected tate changed, the device will unsolicited
to send the "Sensor Multilevel Report" to the nodes in the group 1.
Caution 1: Enable this functionality, it will cause the PIR Motion to
disable detection when the temperature measurement. In other words,
The PIR motion will blind one second in every one minute.
* Timing Report:
Beside the event triggered could report message, the device also
support the timing unsolicited report of the status.
Battery level report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 10.
Low battery report: When the battery level is too low, every 30
minutes will report once.
Notice: The configuration NO. 10, 11, 12 and 13 could be setting to
zero to disable the auto report. And the configuration NO. 20 could
change the tick interval, the default value is 30, if setting to 1, that
means the minimum auto report interval will be one minute. And please
notice if setting this value to zero, that means disable all of the timing
All manuals and user guides at all-guides.com
report except the low battery detection.

Power Up Procedure

* Battery Power Check
When the device power up, the device will detect the power level of the
battery immediately. If the power level is too low, the LED will continue
flash about 5 seconds. Please change another new battery.
* PIR Warm Up
When the device power on, the PIR need to warm up before the
operation. The warm up time about 1 minute, the LED will flash in
every 2 seconds. After finish the procedure the LED will light ON three
times.
* NWI
When the device power on, the device will check is it already adding to
the network? If doesn't, it will auto start the NWI mode. The LED will
flash in every second and continue 30 seconds. Until timeout or the
device successful to inclusion by controller. The use can presses the
tamper key 3 times to abort the NWI mode.
* Wake
When the device power on, the device will wake about 20 seconds. In
this duration, the controller can communicate with the device. Normally
the device is always sleeping to save the battery energy.

Security Network

The device support the security function. When the device included
with a security controller, the device will auto switch to the security
mode. In the security mode, the follow commands need using Security
3

Advertisement

Table of Contents
loading