Table of Contents Important Safety Instructions..........................3 Warranty..................................4 Assembly of your Lift Chair Cord and Transformer Connections.......................6 Chair Assembly................................7 Operating Your Lift Chair............................8 Installing Back-Up Batteries..........................9 Lithium-Ion Battery Pack Back-Up System....................10 Troubleshooting................................11 NOTE: When placing the furniture on non-carpeted flooring, K Care Healthcare Solutions recommend the use of floor protection such as an area rug or furniture pads.
Important Safety Instructions READ ALL INSTRUCTIONS BEFORE USING. WARNING: To reduce the risk of burns, fire, electric shock, or injury to persons: DANGER: To reduce the risk of electric shock, always unplug this furnishing from the electrical outlet before cleaning. Unplug from outlet before putting on or taking o parts.
WARRANTY WARRANTY AGAINST DEFECTS IN GOODS PRODUCT PART WARRANTY PERIOD Steel Frame Five (5) Years Motor Five (5) Years Electronics Two (2) Years Handset & Cable Two (2) Years Scissor Mechanisms Five (5) Years Five (5) Years Steel Lift Mechanism Two (2) Years Fabric K Care Healthcare Solutions provides consumers with the following warranty in relation to this Product,...
Page 5
You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Contact information K Care Healthcare Solutions Telephone 1300 783 783 836A Fifteenth Street Facsimile 1300 784 784 Mildura VIC 3500 Email customerservice@kcare.com.au...
CORD AND TRANSFORMER CONNECTIONS Once the box has been removed from around the chair, you'll notice the back is resting Remove the zip �e holding the plas�c bag with the Power Transformer, hand wand and on top of the seat. There are a couple of items to remove from the seat portion of the chair first.
CHAIR ASSEMBLY: ATTACHING THE CHAIR BACK TO THE CHAIR BASE CAUTION: PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING ASSEMBLY PROCESS. IT IS RECOMMENDED TO USE TWO PEOPLE WHEN ASSEMBLING AND REMOVING THE INSIDE BACKS TO AND FROM THE BASE OF THE FURNITURE. Slide inside back receivers onto the steel mechanism posts in the base of the chair (Figure A).
CHAIR ASSEMBLY: ATTACHING THE CHAIR WINGS TO THE CHAIR BACK Slide the metal inserts on the chair’s wings into the metal sleeves on the side of the chair back. Slide the wings down until they are completely set on the back's metal sleeves.
INSTALLATION OF BACK-UP BATTERIES 2 - 9 Volt back-up batteries will lift the chair from the reclined position to the seating position in case of a power failure. If a power failure occurs and the chair is cycled, the 2-9 Volt batteries will need to be replaced.
LITHIUM-ION BATTERY PACK BACK-UP SYSTEM If your chair is equipped with an external transformer with a lithium-ion battery pack, your chair may be operated without being plugged into an electrical outlet for up to 48 hours. LITHIUM-ION POWER CORD BATTERY PACK Figure A Chair Battery Back-up Location Follow these steps to replace the lithium-ion battery pack batteries:...
TROUBLESHOOTING PROBLEM POSSIBLE FACTORS SOLUTIONS Check the power supply has been correctly connected to the The transformer may not be The chair doesn’t recline or lift socket and confirm the wire from connected well chair to transformer is firmly connected Check the headrest and lumbar The headrest or lumbar doesn’t The headrest or lumbar motor...
Page 15
All information is considered to be true and correct at the date of publication. Changes in circumstances after the time of publication may impact on the accuracy of the information. 202002_1.2...
Page 16
Improving your life everyday ™ At Your Service Sales, administration and general enquiries National 1300 783 783 Your Customer Service Team customerservice@kcare.com.au kcare.com.au...