Bauer 20204L-B, 57932 - 16 Ft. Tile/Flooring Laser Level Manual

Bauer 20204L-B, 57932 - 16 Ft. Tile/Flooring Laser Level Manual

Also See for 20204L-B:

Advertisement

Bauer 20204L-B, 57932 - 16 Ft. Tile/Flooring Laser Level Manual

IMPORTANT SAFETY INFORMATION

WARNING SYMBOLS AND DEFINITIONS

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
Addresses practices not related to personal injury.

Safety Warnings and Precautions


Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.

Save all warnings and instructions for future reference.

  1. Never attach or use any other form of optical device with this product. Use as intended only.
  2. Do not modify in any way as this may result in hazardous radiation exposure.
  3. This product is not a toy. Do not allow children to play with or near this item.
  4. Inspect before every use; do not use if parts are loose or damaged.
  5. Avoid damaging Laser Level. Use only as specified in this manual.
  1. Power this Laser Level using only the batteries referenced in the Specifications Chart.
  2. Stay alert. Watch what you are doing, use common sense. Do not operate any Laser Level when you are tired.
  3. Do not operate Laser Level if under the influence of alcohol or drugs. Read warning labels on prescriptions to determine if your judgment or reflexes are impaired while taking drugs. If there is any doubt, do not operate the Laser Level.
  1. Do not look into laser. Do not point laser at persons or animals directly or indirectly off of reflective surfaces.
  2. Performance of this Laser Level may vary depending on battery condition.
  3. The Laser Level is a delicate instrument; do not drop or jar the Laser Level.
  4. Maintain product labels and nameplates. These carry important safety information. If unreadable or missing, contact Harbor Freight Tools for a replacement.
  5. Do not install old and new batteries together. Do not install alkaline, carbon-zinc or rechargeable batteries together. Position batteries in proper polarity. Do not use swollen or leaking batteries.
  1. Do not attempt to charge batteries
  2. Have the Laser Level calibrated by a qualified technician every year to maintain accurate results.
  3. People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure.
  4. The warnings, cautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.

warningSAVE THESE INSTRUCTIONS.

Specifications

Working Range Up to 16.4 ft (5 meters)
Accuracy ± 0.5mm/m (± 3/16" @ 33 ft)
Battery 2x AA (Included)
Operating Temperature 32°F - 104°F (0°C - 40°C)
Operating Environment Indoors


LASER LIGHT DO NOT STARE INTO BEAM

Max. Output: <1mW
Wavelength: 635 nm

CLASS II LASER PRODUCT
This product complies with
21 CFR 1040.10 and 1040.11

Distributed by
Harbor Freight Tools
26677 Agoura Road
Calabasas, CA 91302
Manufacture Date

Setup - Before Use

warningRead the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

Functions

Functions

Operating Instructions

warningRead the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

General Operation

  1. Install batteries as described in "Battery Replacement".
  2. Set the Level on a flat, level surface.
  3. To mark guidelines:
    1. Place the bottom on the Level on the floor or wall. Press the Power Switch to turn on the laser.
    2. Place the T-Edge against a wall so that the laser lines run parallel to reference lines.
      General Operation - Step 1
  1. If on the wall, align the Level so that the 0° Alignment Bubble is level and the 90° Alignment Bubble is at the top.
  2. If on the floor, align the Level so that both Alignment Bubbles are level.
  1. To lay tiles on the floor:
    1. Position Level in a corner so that laser lines run parallel to the reference lines as shown in Step 3.
    2. Lay the first tile so that the sides are flush with the 0° and 90° laser lines.
    3. If laying next to an edge, position the Level so that the T-Edge is against the side of the edge. The 90° laser line should run parallel to the edge and the 0° laser line marks the tile row.
      General Operation - Step 2
  1. To apply tiles to a wall:
    1. Determine the height at which the first tile row should begin and mark the wall using the ruler on the Level or other measuring device.
    2. Place the T-Edge at the mark and straighten the Level so that the 0° laser line is parallel with the floor.
      General Operation - Step 3
  1. To check the alignment of a row of tiles, place L-Edge at the corner of a tile.
    General Operation - Step 4
  1. To check the alignment of a single tile, place the Level's edge on top of the tile as shown below.
    General Operation - Step 5
  1. When finished with the Level, press the Power Switch to turn it OFF. Store Level in a dry indoor area away from children, If storing for a long period, remove the batteries.

Maintenance and Servicing

warningProcedures not specifically explained in this manual must be performed only by a qualified technician.

Cleaning, Maintenance, and Lubrication

  1. Wipe unit with a dry, lint-free cloth. Do not use solvents or abrasives.
  2. Remove batteries if not in use for long periods.
  3. Store unit in a dry location.
  1. Other than the batteries, there are no replaceable parts on this unit. Repairs should be done by a qualified technician.

Battery Replacement

Battery Replacement

  1. Turn the Level's Power Switch OFF.
  2. Remove battery cover by pressing the Latch and removing the cover.
  3. Remove old batteries. Replace with new AA batteries follow polarity.
  1. Replace battery cover and be sure the Latch connects securely.

Note: Do not install old and new batteries together. Do not install alkaline, carbonzinc or rechargeable batteries together. Position batteries in proper polarity. Do not use swollen or leaking batteries.

Calibration

Have the Laser Level calibrated by a qualified technician every year.

Record Serial Number Here:
Note: If product has no serial number, record month and year of purchase instead.

Note: Replacement parts are not available for this item.
Reference UPC 193175427045.

Visit our website at: http://www.harborfreight.com
Email our technical support at: productsupport@harborfreight.com

For technical questions, please call 1-888-866-5797.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Bauer 20204L-B, 57932 - 16 Ft. Tile/Flooring Laser Level Manual

Advertisement

Need Assistance?

Do you have a question about the 20204L-B that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents