  • Page 1 s6oo arti / s9oo arti scanner operator’s and maintenance manual...
  • Page 2 02 02 Operator’s and maintenance manual S600 ARTI / S900 ARTI Scanner Machine type: Scanner Version 10/06/2019 Copyright 2019 Zirkonzahn S.r.l.
  • Page 3 03 03...
  • Page 4: Table Of Contents

    S600 ARTI / S900 ARTI Scanner ........
  • Page 5 Connection of the S600 ARTI / S900 ARTI Scanner .......
  • Page 6: Symbols Used In This Operator's And Maintenance Manual

    06 06 SYMBOLS USED IN THIS OPERATOR’S AND MAINTENANCE MANUAL Caution: Source of danger! Caution: Hazardous voltage! Caution: Danger of explosion! Prohibition: Access by unauthorised personnel is strictly forbidden! Prohibition: Touching moving parts is strictly forbidden. Prohibition: Repair and maintenance work on moving parts is strictly forbidden! Prohibition: The use of water, compressed air or solvents is strictly forbidden! Mandatory sign: Unplug from mains power! This symbol refers to the operating company’s binding legal rules or requirements.
  • Page 7: Checklist Of Components - Standard Version

    Mouse Screen Video cable for screen Power cable for screen Operator’s and maintenance manual Installation plan for the S600 ARTI / S900 ARTI Scanner Equipment accessories: Dongle for the Zirkonzahn.Scan software Universal Model Holder Calibrating Plate Allen key set with ballpoint heads...
  • Page 8 08 08...
  • Page 9: Safety / Residual Risks

    Manual as Zirkonzahn. GENERAL INFORMATION This Operator’s and Maintenance Manual is an integral part of the S600 ARTI / S900 ARTI Scanner and must be kept in a place known to the operator and easily and immediately accessible at all times. Only adequately trained personnel should handle the S600 ARTI / S900 ARTI Scanner.
  • Page 10: Service

    The intended use of the scanner is outlined in this chapter. In this connection a hazard analysis was done on the S600 ARTI / S900 ARTI Scanner. The manufacturer does not accept any responsibility for applications not described here which do not fall within the definition of intended use.
  • Page 11: Warranty

    From the moment of delivery, Zirkonzahn grants a warranty of 12 months for the equipment. If the S600 ARTI / S900 ARTI Scanner is passed on to third parties, the warranty obligation is recognized only if the passing on occurs within the set warranty period of 12 months.
  • Page 12: Safety Regulations

    Your safety comes first! Safety concept The safety concept of the S600 ARTI / S900 ARTI Scanner as well as this Operator’s and Maintenance Manual were compiled according to the requirements of the Machinery Directive 98/37/EC in force until 29/12/2009 and the Machinery Directive 2006/42/EC in force since 30/10/2009, as well as the European Low Voltage Directive (LVD) 2006/95/ EC.
  • Page 13: Sources Of Danger And Risks

    CHAPTER 1 13 13 SAFETY / RESIDUAL RISKS SOURCES OF DANGER AND RISKS Possible sources of danger According to the safety technical hazard analysis 09/02/2009, Machinery Directive 2006/42/EC; 98/37/EC; Low voltage Directive (LVD) 2006/95/EC. - Rotating parts. - Moving parts - Front plate.
  • Page 14: Transport, Unpacking And Setting Up Of The Equipment

    - For the pallet’s transport the use of a forklift truck is recommended. Caution when lifting! - The S600 ARTI / S900 ARTI Scanner may only be moved and put down on surfaces with suitable stability, in a dry place and in a non-corrosive environment.
  • Page 15: Sgs Declaration Of Conformity For Scanner

    CHAPTER 1 15 15 SAFETY / RESIDUAL RISKS...
  • Page 16 CHAPTER 1 16 16 SAFETY / RESIDUAL RISKS...
  • Page 17: Components And Accessories

    CHAPTER 2 17 17 COMPONENTS AND ACCESSORIES COMPONENTS AND ACCESSORIES S600 ARTI Scanner and S900 ARTI Scanner with customisable glass design...
  • Page 18: S600 Arti / S900 Arti Scanner

    CHAPTER 2 18 18 COMPONENTS AND ACCESSORIES S600 ARTI / S900 ARTI SCANNER 01. Ventilation fan 30. Glass fuse for circuit board T 1,25A / 250 V 02. Camera trigger cable 31. Mains plug (110 V / 240 V – 50 Hz / 60 Hz) 03.
  • Page 19 CHAPTER 2 19 19 COMPONENTS AND ACCESSORIES S900 ARTI Scanner front (open)
  • Page 20 CHAPTER 2 20 20 COMPONENTS AND ACCESSORIES Ventilation fan (01), camera (04), mirror holder projector (09) Trigger cable camera (02), projector (10) IR-Projector control cable (11) HDMI plug (12) projector power cable (13) Images S900 ARTI Scanner...
  • Page 21 CHAPTER 2 21 21 COMPONENTS AND ACCESSORIES PS1 Articulator (optional) (14) Universal model holder (15) Calibrating plate (16), Laser (07)
  • Page 22 CHAPTER 2 22 22 COMPONENTS AND ACCESSORIES S900 ARTI Scanner rear side (closed)
  • Page 23 CHAPTER 2 23 23 COMPONENTS AND ACCESSORIES Projector control *Equipment only available for the S900 ARTI Scanner.
  • Page 24: Accessories

    (Easy-Fix) ZBAC2251 – Clamping Claw for Easy-Fix incl. model fixing pin ZBAC2251 – Clamping Claw for Easy-Fix ZBAC2211 – Positioning Plate ZBAC0801 – Articulator mounting S600 ARTI ZBAC2301 – Multi-Die Holder Articulator mounting S900 ARTI Scanner SYAA0350 – PS1 Articulator...
  • Page 25: Technical Data

    CHAPTER 3 25 25 TECHNICAL DATA TECHNICAL DATA - Processing axes - Overall height 69 cm - Depth 41 cm - Width 48 cm - Weight 56 kg - Glass front plate, covering Hardened Securit Glass UNI ISO 12150 - Operating voltage 110 - 240 V - Power input 0.9 A (1.9 A)
  • Page 26: Device Id Plate

    Transport, install, connect and set up the equipment according to the aforementioned indications. Device ID plate The Device ID plate of the S600 ARTI / S900 ARTI Scanner is attached on the rear of the equipment.
  • Page 27: Installation / First Start-Up

    Pallet 20 kg - The S600 ARTI / S900 ARTI Scanner is supplied on a pallet and encased by a cardboard box. - Do not put any object on top of the cardboard box. - Caution when removing the cardboard box (glass lining).
  • Page 28: Setting Up And Installation

    - Maximum relative air humidity of 75 % at 30 °C; - The S600 ARTI / S900 ARTI Scanner may only be moved and put down on surfaces with suitable stability, in a dry place and in a non-corrosive environment.
  • Page 29: First Start-Up

    CHAPTER 4 29 29 INSTALLATION / FIRST START-UP - The leakage current is 20 mA AC; however, it can also be higher at the starting torque. - Provide a suitable alternative protective measure. - Permissible residual-current circuit breakers, Type A or B (30 mA). - The use of residual-current circuit breakers, Type AC, is prohibited! The release via a residual-current circuit breaker at the first start-up is generally a fault of the power connection, not of the device.
  • Page 30: Connection Of The Pc

    CHAPTER 4 30 30 INSTALLATION / FIRST START-UP CONNECTION OF THE PC 01. Connect the screen to the PC. 02. Insert dongle (Zirkonzahn.Scan), if it is not yet connected to the PC. 03. Insert dongle (Zirkonzahn.Modellier), if it is not yet connected to the PC. 04.
  • Page 31: Connection Of The Scanner To The Dell Precision Tower 3620

    CHAPTER 4 31 31 INSTALLATION / FIRST START-UP CONNECTION OF THE SCANNER TO THE DELL PRECISION TOWER 3620 Internet connection...
  • Page 32: Connection Of The Scanner To The Dell Precision Tower 5810

    CHAPTER 4 32 32 INSTALLATION / FIRST START-UP CONNECTION OF THE SCANNER TO THE DELL PRECISION TOWER 5810 Internet connection...
  • Page 33: Operation

    CHAPTER 5 33 33 OPERATION OPERATION TRAINING AND PRACTICE The training on device operation with demos of the several possibilities of application is best achieved by a CAD/CAM introductory course by Zirkonzahn. Professional handling, safety measures and the most efficient use of the scanner will be conveyed during the course.
  • Page 34: Operation

    CHAPTER 5 34 34 OPERATION OPERATION 01. Preparation of the working model: - Block out undercuts on dies with scan-wax. - Create a mushbite which will be used as antagonist. - Spray dies evenly with the Scan-Spray. 02. Check the scanner’s power supply as well as the PC’s power supply. 03.
  • Page 35: Cleaning And Maintenance

    CHAPTER 6 35 35 CLEANING AND MAINTENANCE CLEANING AND MAINTENANCE SAFETY MEASURES WHEN CLEANING THE DEVICE ATTENTION: When designing the device we assumed that all operators have a basic technical knowledge. Therefore, all cleaning and maintenance work can be easily carried out without professional help.
  • Page 36: Maintenance And Control

    - Visual inspection of the equipment's interior for damages or impurity. If after inspection defects are detected, the S600 ARTI / S900 ARTI Scanner may not be used. The device must be shut down and secured against unauthorised access. For trouble shooting please contact our Zirkonzahn Support: Tel.
  • Page 37: Repairs And Troubleshooting

    CHAPTER 7 37 37 REPAIRS AND TROUBLESHOOTING REPAIRS AND TROUBLESHOOTING DETECTED FAULTS If malfunctions or defects are detected during the maintenance of the device, these must be remedied before the renewed start-up, in order to ensure a trouble-free and safe operation. Defects, damages and malfunctions must be reported without delay to Zirkonzahn or to the service centres specified in your maintenance contract.
  • Page 38: Front Plate Exchange

    CHAPTER 7 38 38 REPAIRS AND TROUBLESHOOTING FRONT PLATE EXCHANGE Pay attention to the spring-loaded arm assembly when replacing the front plate! Replacement has to be done under the guidance of Zirkonzahn or the service centres specified in your maintenance contract.
  • Page 39 CHAPTER 7 39 39 REPAIRS AND TROUBLESHOOTING...
  • Page 40 HUMAN ZIRCONIUM TECHNOLOGY Zirkonzahn Worldwide – Tel +39 0474 066 660 – info@zirkonzahn.com – www.zirkonzahn.com All information is subject to change. Errors and omissions excepted. Version: 10/06/2019...