Advertisement

WAREFORCE SERIES
UNDERCOUNTER
DISHMACHINES
INSTALLATION, OPERATION,
AND SERVICE MANUAL
WAREFORCE UH30-FND
WAREFORCE UL30
WAREFORCE UH30-FND/UL30 Manual • 07610-004-37-37-P

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UL30 and is the answer not in the manual?

Questions and answers

Summary of Contents for Wareforce UL30

  • Page 1 WAREFORCE SERIES UNDERCOUNTER DISHMACHINES INSTALLATION, OPERATION, AND SERVICE MANUAL WAREFORCE UH30-FND WAREFORCE UL30 WAREFORCE UH30-FND/UL30 Manual • 07610-004-37-37-P...
  • Page 2 QOF-386 and added length. Added color and length to items 6 and 7 on UH30-FND Chemical Feeder Pump Assembly page. Added the 100" chemical tubes for red, white, and blue to UL30 Chemical Feeder Pump Assembly page. Updated pg. 2. Corrected references to flow pressure on pg. 6. Updated references to E and 8585 F outputs on pgs.
  • Page 3 NOMENCLATURE WAREFORCE UH30-FND Undercounter dishmachine; high-temperature, hot-water sanitizing, with a booster tank and detergent and rinse-aid chemical feeder pumps. WAREFORCE UL30 Undercounter dishmachine; low-temperature with wash tank heater, chemical-sanitizing, with detergent, rinse-aid, and sanitizer chemical feeder pumps. The manufacturer provides...
  • Page 4: Table Of Contents

    Thermostats ........................7 Chemical Feeder Equipment ................... 8 Preparing Chemical Feeder Pumps ................. 8 Priming Chemical Feeder Pumps ..................8 Programming Chemical Feeder Pumps (UL30) ............... 9 Leveling.......................... 12 Initial Fill (UH30-FND Only) ................... 12 OPERATION Operating Instructions ........................13 Preparation ........................
  • Page 5 Stands & Components ........................61 UL30 Heater Components ......................62 UL30 Vacuum Switch ........................63 UL30 Vacuum Switch Install ......................64 SCHEMATICS UH30-FND 208-240 V, 50/60 Hz, 1/3 Phase ................. 65 UL30 115 V, 50/60 Hz, 1 Phase ..................... 66...
  • Page 6: Guides

    GUIDES GUIDES SYMBOLS - Risk of Injury to Personnel WARNING - Risk of Damage to Equipment CAUTION - Risk of Electrical Shock - Caustic Chemicals - Reference Data Plate - Lockout Electrical Power - Important Note NOTICE  - Instructions Hyperlink ABBREVIATIONS &...
  • Page 7: Specifications

    MACHINE DIMENSIONS SPECIFICATIONS LEGEND A - Electrical Connection C - Drain Hose (1" ID, install into 1 1/2" MIN Drain with Air-gap) B - Water Inlet (with 6' Hose) (3/4" Male GHT, connect to true All dimensions from the floor can be increased 1” 1/2"...
  • Page 8: Operating Parameters

    OPERATING PARAMETERS SPECIFICATIONS Operating Capacity: UH30-FND UL30 Racks per Hour Dishes per Hour Glasses per Hour Gallons per Rack Gallons per Hour 26.4 28.8 Tank Capacity (Gallons): Wash Tank Rinse Tank Electrical Loads (as applicable): Wash Motor HP Rinse Heater kW 6.7 (208 V)/8.2 (230 V)
  • Page 9: Electrical Requirements

    37.2 A 40.7 A LOAD • 115 V, 60 Hz, Single-phase UL30 Available Wash Tank Heater: • 1.5 kW (UL30 Only) VOLTS *Motor and heater do not operate at same time. Total load based on motor load. PHASE FREQ WASH MOTOR 10.0 A...
  • Page 10: Installation Instructions

    INSTRUCTIONS INSTALLATION INSPECTION Before installing the unit, check packaging and machine for damage. Damaged packaging might be an indication of damage to the machine. If there is any type of damage to both packaging and unit, do not throw away the packaging. The Do not throw away dishmachine has been inspected at the factory before shipping and is expected container if damage is...
  • Page 11: Pressure Regulator

    INSTRUCTIONS INSTALLATION WATER SUPPLY A water hardness test must be performed. If water hardness is higher than 3 GPG and a water softener is not being used, install an SPS (see Plumbing Options CONNECTIONS: page) into the water line between the facility water line and the machine water line WATER HARDNESS (installed at the factory).
  • Page 12: Electrical Power Connections

    Install the service wires (L1 and L2 for UH30-FND, L1 and procedures and codes. N for UL30) to the appropriate terminals as they are marked on the terminal block. Install the grounding wire into the lug provided. It is recommended that “DE-OX” or another similar anti-oxidation agent be used on all power connections.
  • Page 13: Chemical Feeder Equipment

    The UH30-FND dishmachine is supplied with detergent and rinse-aid chemical feeder pumps. CHEMICAL FEEDER PUMPS The UL30 dishmachine is supplied with detergent, rinse-aid, and sanitizer chemical feeder pumps. Locate the open ends of the chemical tubes with the tube stiffeners and place each one in the appropriate container.
  • Page 14: Programming Chemical Feeder Pumps (Ul30)

    7. Sanitizer is dispensed proportionally into the final rinse water line. The amount of sanitizer might need to be adjusted depending on concentration. 8. See Programming Chemical Feeder Pumps (UL30) section to adjust chemical amounts using the universal timer. PROGRAMMING To access programming mode, machine must be ON and between cycles.
  • Page 15 2. Programming board and buttons are not labeled on the timer. Use the graphic below for reference. CHEMICAL FEEDER LIGHTS TIME PUMPS (UL30) ACCEPT MOVE BUTTONS ENTER 3. Press and hold both the MOVE and ENTER buttons simultaneously for two seconds then release.
  • Page 16 INSTALLATION PROGRAMMING 5. Press ENTER button. PGM light will stay steady, lights for the current time setting will come on, and ACCEPT light will start flashing. CHEMICAL FEEDER PUMPS (UL30) LIGHTS TIME Example here shows current setting for G = Light Steady at 9.2 seconds (each...
  • Page 17: Leveling

    INSTRUCTIONS INSTALLATION PROGRAMMING 8. Press ENTER button. This saves the changed parameters and exits the programming mode. PGM light will go from steady to flashing. CHEMICAL FEEDER PUMPS (UL30) LIGHTS TIME ACCEPT MOVE BUTTONS ENTER 9. To change any other values, repeat the process above. To revert back to a previous setting, repeat the process above and change parameters back to previous settings.
  • Page 18: Operation

    See Initial Fill section for UH30-FND models. 3. Machine will automatically begin to fill. 4. Once wash tub is filled, wait until wash temperature is at least 150 °F for UH30- FND and 120 °F for UL30 before operating machine. 07610-004-37-37-P...
  • Page 19: Ware Preparation

    4. LED will turn green. Operator has three seconds to close door before LED goes out and START button must be pressed again. 5. Cycle automatically starts when door is closed. UL30 1. Ensure machine is on and at operating temperature. 2. Open door and load rack.
  • Page 20: Shutdown & Cleaning

    OPERATING INSTRUCTIONS OPERATION SHUTDOWN & 1. At end of workday, close door. UH30-FND: Press POWER button. UL30: Flip ON/ OFF switch to OFF position. CLEANING UH30-FND UL30 2. Drain pump will activate and empty machine of water. 3. When draining stops, remove strainer.
  • Page 21 7. Reassemble wash and rinse arms. 8. Replace wash and rinse arms. The arms only need to be hand-tight, do not use tools to tighten them down. UL30 has combined wash/ rinse arms. 9. Reinstall strainer and close door. 07610-004-37-37-P...
  • Page 22: Deliming Uh30-Fnd

    OPERATING INSTRUCTIONS OPERATION DELIMING 1. Remove rinse arms and place in sink with deliming solution (leave for amount of time recommended by chemical supplier). UH30-FND If machine is equipped with an SPS and lime is becoming a frequent problem, the cartridge needs to be replaced.
  • Page 23: Deliming Ul30

    6. Wait until cycle is complete and inspect inside of machine. If machine is not delimed, run again. UH30-FND and UL30: This equipment is not recommended for use with deionized NOTICE water or other aggressive fluids. Use of deionized water or other aggressive fluids will result in corrosion and failure of materials and components.
  • Page 24: Detergent Control

    OPERATING INSTRUCTIONS OPERATION DETERGENT Detergent usage and water hardness are two factors that greatly contribute to the machine's operating efficiency. Using the proper amount of detergent can become a CONTROL source of substantial savings. A qualified water-treatment specialist can determine what is needed for maximum efficiency from the detergent.
  • Page 25: Maintenance

    PREVENTATIVE MAINTENANCE MAINTENANCE PREVENTATIVE The manufacturer highly recommends that only qualified service personnel perform any maintenance and repairs not specifically discussed in this manual. MAINTENANCE WARNING! Unqualified personnel performing maintenance on the machine may void the warranty, lead to larger problems, or cause harm to the operator. WARNING By following the operating and cleaning instructions in this manual, you should get the most efficient results from your machine.
  • Page 26: Troubleshooting

    UH30-FND SETPOINTS TROUBLESHOOTING RINSE TEMP To access Setpoints, the machine must be on and not in cycle. 1. Push and hold cycle button a minimum of six seconds. Temperature shows on left display and will flash on and off. Adjustable Setpoints: Rinse Temp 180 °...
  • Page 27 UH30-FND SETPOINTS TROUBLESHOOTING DETERGENT 1. Once setting changes to detergent time, current setting will flash on and off. TIME If there is no activity (button presses) for 30 seconds, display will exit 2. Press prime button (left rocker to increase and right rocker to decrease). This Setpoints mode without changes detergent time one second at a time.
  • Page 28 UH30-FND SETPOINTS TROUBLESHOOTING DETERGENT 1. Once setting changes to detergent priming time, current setting will flash on and off. PRIMING TIME If there is no activity (button presses) for 30 seconds, display will exit 2. Press prime button (left rocker to increase and right rocker to decrease). This Setpoints mode without changes detergent priming time one second at a time.
  • Page 29 UH30-FND SETPOINTS TROUBLESHOOTING TEMPERATURE 1. Once setting changes to temperature scale, °F or °C will flash on and off. SCALE ° f If there is no activity (button presses) for 30 seconds, display will exit 2. Press prime button to switch to other setting. Setpoints mode without saving changes.
  • Page 30: Uh30-Fnd Fault Codes

    UH30-FND FAULT CODES TROUBLESHOOTING DISPLAY SHOWS POSSIBLE CAUSES REMEDY 1. Verify incoming water pressure is 10 ± 2 PSI. 1. Low or no water pressure. 2. Verify that fill relay is supplying voltage to fill solenoid. Replace faulty component. 2. Faulty inlet valve or fill relay. 3.
  • Page 31 UH30-FND FAULT CODES TROUBLESHOOTING DISPLAY SHOWS POSSIBLE CAUSES REMEDY 1. Verify incoming water pressure is 10 ± 2 PSI. 1. Low or no water pressure. 2. Verify that fill relay is supplying voltage to fill solenoid. 2. Faulty inlet valve or fill relay. Replace faulty component.
  • Page 32 UH30-FND FAULT CODES TROUBLESHOOTING DISPLAY SHOWS POSSIBLE CAUSES REMEDY "F12 Service needed," "Check booster Faulty temperature probe (T3). Replace probe that connects to P13. thermostat" 1. Fully disconnect 6-pin cable at each end, and reconnect 1. Loose connection in 6-pin cable between each end until a click is heard.
  • Page 33: Troubleshooting

    TROUBLESHOOTING TROUBLESHOOTING WARNING! Inspection, testing, and repair of electrical equipment should only be performed by qualified service personnel. Certain procedures in this section require electrical tests or measurements while power is applied to the machine. Exercise extreme caution at all times. If test points are not easily accessible, disconnect WARNING power, attach test equipment, and reapply power to test.
  • Page 34 TROUBLESHOOTING TROUBLESHOOTING WARNING! Inspection, testing, and repair of electrical equipment should only be performed by qualified service personnel. Certain procedures in this section require electrical tests or measurements while power is applied to the machine. Exercise extreme caution at all times. If test points are not easily accessible, disconnect WARNING power, attach test equipment, and reapply power to test.
  • Page 35: Parts

    UH30-FND CONTROL PANEL PARTS NOTICE Machines with serial numbers before 23D415452 have a different control panel. Click here to open earlier manual. 07610-004-37-37-P...
  • Page 36 UH30-FND CONTROL PANEL PARTS ITEM DESCRIPTION PART NUMBER Contactor, 30 A, 240 VAC 05945-002-74-20 I/O Module 06401-005-10-88 End Bracket, Terminal 05999-004-90-66 Separator, Terminal Block 05999-004-90-67 Terminal Block, Single Level 05999-004-90-68 Tag, Marking 05999-004-90-72 Power Supply 05950-004-81-79 Peri-pump Assembly, 14 RPM 05700-004-71-63 Din Rail, 5 3/4"...
  • Page 37: Ul30 Control Panel

    UL30 CONTROL PANEL PARTS ITEM DESCRIPTION PART NUMBER Contactor, 110 V 05945-109-05-69 Relay, Omron 05945-002-47-41 Open/Closed Bushing 05975-003-35-21 Control Panel Weldment 05700-004-35-76 Universal Timer 05945-003-75-23 Screw, 10-32 x 1" 05305-002-19-42 Thermostat Plate 05700-004-37-67 Thermostat, Electric 06685-004-17-27 Screw, 10-32 x 3/8"...
  • Page 38: Uh30-Fnd Display Panel

    UH30-FND DISPLAY PANEL PARTS NOTICE Machines with serial numbers before 23D415452 have a different display panel. Click here to open earlier manual. ITEM DESCRIPTION PART NUMBER Switch, Power 05930-004-85-60 Switch, Prime 05930-004-97-47 Display, LED 05945-004-85-61 Bracket, Display Panel 05700-005-07-33 Decal, Display Panel 09905-005-06-64 Switch, Cycle 05700-003-14-91...
  • Page 39: Ul30 Display Panel

    UL30 DISPLAY PANEL PARTS ITEM DESCRIPTION PART NUMBER Bracket, Control Panel 05700-004-37-73 Thermometer, 48" Rinse 06685-004-31-47 Light, Red 05945-504-07-18 Prime Switch 05930-011-49-54 Switch 05930-011-49-55 Light, Red 05945-111-44-45 Decal, Hi-Limit Ring 09905-004-37-89 Counter 05990-111-35-38 Light, Amber 05945-111-44-44 Light, Green 05945-111-44-43 Decal, Display Panel...
  • Page 40: Terminal Block Box

    TERMINAL BLOCK BOX PARTS ITEM DESCRIPTION PART NUMBER Decal, Power Connections, UH30-FND 09905-011-62-72 Decal, Power Connections, UL30 09905-011-47-64 Terminal Block Box 05700-003-27-69 Terminal Box Cover (Not Shown) 05700-003-27-70 Decal, Copper Conductors 09905-011-47-35 Screw, 10-32 x 1/2" 05305-011-39-36 Ground Lug 05940-200-76-00...
  • Page 41: Uh30-Fnd Chemical Feeder Pumps

    UH30-FND CHEMICAL FEEDER PUMPS PARTS NOTICE Machines with serial numbers before 23D415452 have different pumps. Click here to open earlier manual. ITEM DESCRIPTION PART NUMBER Pump Housing 04320-111-37-09 Screw, 8-32 x 3/8" Phillips 05305-011-37-07 Roller, Plastic 04320-002-82-28 Pump Cover 04320-111-37-08 Screw, 6-32 x 3/4"...
  • Page 42: Ul30 Chemical Feeder Pump Assembly

    UL30 CHEMICAL FEEDER ASSEMBLY PARTS ITEM DESCRIPTION PART NUMBER Complete Peri-pump Assembly, 14 RPM* 05700-004-71-61 Complete Peri-pump Assembly, 36 RPM* 05700-004-71-60 Tubing, White, 1/4" x 48" 05700-002-62-13 Tubing, Blue, 1/4" x 48" 05700-002-62-11 Tubing, Red, 1/4" x 48" 05700-002-62-12 Tubing, White, 1/4" x 100"...
  • Page 43: Ul30 Chemical Feeder Pumps

    UL30 CHEMICAL FEEDER PUMPS PARTS ITEM DESCRIPTION PART NUMBER Pump Housing 04320-111-37-09 Screw, 8-32 x 3/8" Phillips 05305-011-37-07 Roller, Plastic 04320-002-82-28 Pump Cover 04320-111-37-08 Screw, 6-32 x 3/4" Phillips 05305-011-37-05 Screw, 8-32 x 1/2" Phillips 05305-011-37-06 Tube, Squeeze, 8" 05700-003-22-89...
  • Page 44: Uh30-Fnd Plumbing

    UH30-FND PLUMBING PARTS NOTICE Machines with serial numbers before 23D415452 have different plumbing. Click here to open earlier manual. 07610-004-37-37-P...
  • Page 45 UH30-FND PLUMBING PARTS ITEM DESCRIPTION PART NUMBER Elbow, 1/2" 90-Degree 04730-206-08-00 Adapter, 1/2" x 1/2" 04730-004-97-23 Adapter, Male 04730-401-03-01 Tube, Copper 1/2" x 22" 05700-003-32-16 Vacuum Breaker 04820-003-06-13 Plug, 1/4" Brass 04730-209-01-00 Pipe Clamp 05700-011-38-62 Injector Adapter 05700-031-40-44 Check Valve 04820-111-51-14 Fitting, Outlet Elbow 04820-111-51-18...
  • Page 46: Ul30 Plumbing

    UL30 PLUMBING PARTS 07610-004-37-37-P...
  • Page 47 UL30 PLUMBING PARTS ITEM DESCRIPTION PART NUMBER Vacuum Breaker 04820-003-06-13 Elbow, 1/2" NPT x 3/4" Hose, 45-Degree 04730-003-29-22 Pipe Clamp 05700-011-38-62 Pipe Clamp (Side of Unit) 05700-000-35-05 Hose Union, 1/2" 04720-004-24-68 Male Adapter 04730-401-03-01 Elbow, 1/2" 04730-406-31-01 Copper Pipe, 1/2" x 1 3/8"...
  • Page 48: Plumbing Options

    PLUMBING OPTIONS PARTS SHOCK ABSORBER (WATER ARRESTOR) OPTION Water Arrestor, 1/2” 06685-100-05-00 Tee, 1/2” x 1/2” x 1/2” 04730-211-27-00 Nipple, 1/2” NPT, Brass 04730-207-15-00 Water Arrestor Repair Kit (Plunger & O-ring) 06401-003-06-23 PRESSURE REGULATING VALVE (PRV) OPTION Pressure Regulating Valve, 1/2” 04820-100-04-07 SCALE PREVENTION SYSTEM (SPS) OPTION Replacement Cartridge...
  • Page 49: Vacuum Breaker

    VACUUM BREAKER PARTS VACUUM BREAKER ASSEMBLY 4810-200-03-18 Complete Vacuum Breaker Assembly, 1/2” NPT 04820-003-06-13 ITEM DESCRIPTION PART NUMBER 10 Volt Solenoid Valve Assembly, 1/2” Components of Repair Kit 06401-003-06-23 04810-100-12-18 Coil & Housing only Complete Vacuum Breaker Assembly 1/2” NPT 04820-003-06-13 06401-003-07-43 40 Volt Solenoid Valve Assembly, 1/2”...
  • Page 50: Wash Manifold

    WASH MANIFOLD PARTS See Motor & Pump Page Ball Valve Assembly UH30-FND 04730-003-33-64 UL30 04730-003-34-60 07610-004-37-37-P...
  • Page 51 WASH MANIFOLD PARTS ITEM DESCRIPTION PART NUMBER Hub, Discharge Machine 05700-021-37-90 Gasket, Manifold 05330-200-23-00 Nut, Jam 1 1/2-12 05700-000-86-23 Hose Clamp, 1 5/16” - 2 1/4” #28 04730-719-01-37 Hose, 1 1/4” x 2 1/4” Reinforced 05700-011-44-48 Hose, Bottom Manifold Pump 05700-001-22-92 Clamp, 3/16”...
  • Page 52: Motor & Pump

    MOTOR & PUMP PARTS 07610-004-37-37-P...
  • Page 53 MOTOR & PUMP PARTS Complete Pump & Motor Assembly 06105-004-35-22 ITEM DESCRIPTION PART NUMBER Pump Casing SS, 60 Hz 05700-002-85-00 Impeller, 60 Hz 05700-002-81-86 Mechanical Seal, 60 Hz 05330-002-34-22 Seal Plate, 60 Hz 05700-002-81-87 Case O-ring, 60 Hz 05330-002-81-83 Drain Plug (Not Shown) 04730-002-81-89 Motor Only 06105-004-32-04...
  • Page 54: Rinse Arms & Wash Arms

    RINSE ARMS & WASH ARMS PARTS Complete Wash Arm Assembly 1 per Unit on UH30-FND 2 per Unit on UL30 05700-021-39-23 ITEM DESCRIPTION PART NUMBER Wash Arm with End-cap 05700-021-46-58 Bearing, Assembly 05700-021-35-97 O-ring 05330-002-60-69 End-cap, Wash Arm 05700-003-31-59 07610-004-37-37-P...
  • Page 55 RINSE ARMS & WASH ARMS PARTS Complete Rinse Arm Assembly 2 per Unit on UH30-FND 0 per Unit on UL30 05700-031-39-21 Rinse Arm Bearing Kit 06401-004-57-50 ITEM DESCRIPTION PART NUMBER Retaining Ring 05340-112-01-11 O-ring (included in item #3) 05330-002-60-69 Bearing Assembly, Rinse Arm...
  • Page 56: Uh30-Fnd Rinse Tank

    UH30-FND RINSE TANK PARTS Complete Rinse Tank Assembly 05700-005-08-50 (Items 1–9) NOTICE Machines with serial numbers before 23D415452 have a different rinse tank. Click here to open earlier manual. ITEM DESCRIPTION PART NUMBER Heater, 8.2 kW, 230 V 04540-111-43-21 Gasket, Heater 05330-011-47-79 Lock Washer, 5/16"...
  • Page 57: Uh30-Fnd Door

    UH30-FND DOOR PARTS Complete Door Assembly 05700-005-07-44 NOTICE Machines with serial numbers before 23D415452 have a different door. Click here to open earlier manual. 07610-004-37-37-P...
  • Page 58 UH30-FND DOOR PARTS ITEM DESCRIPTION PART NUMBER Outer Door Weldment 05700-005-07-43 Screw, 10-32 x 1/4" 05305-173-01-00 Bolt, 1/4-20 x 3/8" Hex 05305-274-20-00 Washer, SS 1/4-20 ID 05311-174-01-00 Fastener, 10-32 05340-111-58-10 Door Handle 05700-003-26-62 Stop, Door Hinge 05700-003-32-55 Hinge, Left 05700-003-32-71 Hinge, Right 05700-003-32-72 Inner Door...
  • Page 59: Ul30 Door

    UL30 DOOR PARTS 07610-004-37-37-P...
  • Page 60 UL30 DOOR PARTS ITEM DESCRIPTION PART NUMBER Outer Door Weldment 05700-004-36-55 Screw, 10-32 x 1/4" 05305-173-01-00 Bolt, 1/4-20 x 3/8" Hex 05305-274-20-00 Nut, Lock 10-32 Hex with Nylon Insert 05310-373-02-00 Washer, SS 1/4-20 ID 05311-174-01-00 Bracket, Door Magnet 05700-004-52-68 Door Handle...
  • Page 61: Miscellaneous Door Components

    MISCELLANEOUS DOOR COMPONENTS PARTS UL30 UH30-FND 07610-004-37-37-P...
  • Page 62 Hardware: Locknut, 6-32 Hex with Nylon Insert 05310-373-03-00 Screw, 6-32 x 1/4” Flat Head 05305-171-01-00 Door Switch 05930-003-31-44 Door Switch Bracket 05700-003-31-43 Door Switch & Bracket Assembly 05700-003-32-21 Complete Switch Mount Assembly (UL30) 06401-004-47-76 Complete Switch Mount Assembly (UH30-FND) 05700-005-07-45 07610-004-37-37-P...
  • Page 63: Frame & Panel Components

    FRAME & PANEL COMPONENTS PARTS 07610-004-37-37-P...
  • Page 64 FRAME & PANEL COMPONENTS PARTS ITEM DESCRIPTION PART NUMBER Top Shroud Weldment 05700-003-37-06 Left Shroud Weldment 05700-003-37-04 Right Shroud Weldment 05700-004-36-82 Left Frame Weldment 05700-003-31-91 Swivel Feet 05340-108-02-00 Right Frame Weldment 05700-003-31-90 Hardware: Nut, 1/4-20 Serrated Hex 05310-959-03-00 Nut, 5/16-18 Cad Spine 05310-959-03-00 Bottom Strap 05700-003-92-20...
  • Page 65: Miscellaneous Parts

    Components secured with Locknut, 1/4-20 SS Hex with Nylon Insert 05310-374-01-00 Rail, Left Rack 05700-031-37-89 Rail, Right Rack 05700-031-37-88 Splash Shield 05700-003-33-51 Strainer Spacer 05700-002-70-60 Attaches with: Nut, Nylon Wing, 1/4-20 05310-994-01-00 Strainer Weldment 05700-031-35-81 Drain Water Tempering Kit (UH30-FND) 06401-004-60-64 Switch, Horizontal Float (UL30) 06680-004-05-50 07610-004-37-37-P...
  • Page 66: Stands & Components

    STANDS & COMPONENTS PARTS 6" Stand Install Instructions  18" Stand Install Instructions  ITEM DESCRIPTION PART NUMBER 6” Stand Assembly 05700-003-34-24 Stand 05700-002-88-82 6” Leg 05700-021-61-10 Bullet Foot 05340-108-01-03 18” Stand Assembly 05700-003-34-25 Stand 05700-002-88-82 Bullet Foot 05340-108-01-03 18” Leg 05700-002-89-47 Cross Brace 05700-003-25-90...
  • Page 67: Ul30 Heater Components

    UL30 HEATER COMPONENTS PARTS ITEM DESCRIPTION PART NUMBER Thermostat Bracket 05700-004-36-37 High Limit Thermostat 05930-004-33-15 Probe Bracket 05700-004-38-45 Wash Heater, 115 V, 1.5 kW 04540-004-33-76 Lockwasher, Split, 5/16" 05311-275-01-00 Nut, Hex 5/16-18 05310-275-01-00 Wash Heater Gasket 05330-011-61-34 Thermostat, Electric Dual...
  • Page 68: Ul30 Vacuum Switch

    UL30 VACUUM SWITCH PARTS ITEM DESCRIPTION PART NUMBER Complete Assembly 05700-003-55-98 Box, Vacuum Switch 05700-003-55-96 Switch, Vacuum 06685-003-36-13 Wye, 1/4” Barbed PVDF 04730-003-36-14 Tubing, Clear 5/16" ID 04710-003-53-26 Tube, Red 1/4" OD x 100" Long 05700-003-03-45 Tube, White 1/4" OD x 100" Long 05700-003-03-45 Fitting, Liquidtite .231"...
  • Page 69: Ul30 Vacuum Switch Install

    UL30 VACUUM SWITCH INSTALL PARTS Remove locknut on plumbing support bracket and mount switch box over existing stud. Reinstall bracket and route red and white tubes behind blue hose as shown. Route gray cable down back and under the tub along inlet plumbing, remove wires from existing pressure switches, and connect to gray cable per instructions below.
  • Page 70: Uh30-Fnd 208-240 V, 50/60 Hz, 1/3 Phase

    UH30-FND SCHEMATICS NOTICE Machines with serial numbers before 23D415452 have a different schematic. Click here to open earlier manual. 07610-004-37-37-P...
  • Page 71: Ul30 115 V, 50/60 Hz, 1 Phase

    UL30 SCHEMATICS 07610-004-37-37-P...
  • Page 72 6209 N. US Hwy 25E • Gray, KY 40734 USA 1.888.800.5672 WAREFORCE UH30-FND/UL30 Manual • 07610-004-37-37-P...

This manual is also suitable for:

Uh30-fnd

Table of Contents