Fujitsu AO G12KATA Series Service Instruction page 19

Split type room air conditioner cassette type inverter
Hide thumbs Also See for AO G12KATA Series:
Table of Contents

Advertisement

 Model: AOYG14KATA
Fan speed is defined by outdoor temperature and compressor frequency.
• Outside air temperature zone selection
Cooling
Fan step
Y zone
S-HIGH2
S-HIGH1
HIGH
10
9
8
7
6
5
4
3
2
1
NOTE: After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor frequency.
Fan speed after defrost control: 1,120 rpm
3-2. Outdoor fan control
Outside air
temperature rises
21°C
12°C
2°C
-8°C
Heating
Y zone
1,120
990
1,120
990
1,120
1,120
990
1,120
990
1,120
870
830
830
750
780
710
780
710
670
660
570
500
520
500
Outside air
temperature drops
Y zone
Z zone
F zone
G zone
H zone
Dry
Cooling or dry at low outdoor temp.
Z zone
F zone
990
630
990
630
870
630
830
450
780
450
780
450
670
310
570
200
520
200
- (04-16) -
19°C
10°C
0°C
-10°C
Unit: rpm
G zone
300
280
300
280
300
280
280
220
240
190
240
190
220
190
220
190
200
190
H zone
280
280
280
220
190
190
190
190
190
3. Fan control