ENFORCER SA-027HQ Installation Manual

ENFORCER SA-027HQ Installation Manual

365-day annual timer

Advertisement

365-Day Annual Timer
SA-027HQ
Installation Manual
The ENFORCER SA-027HQ Annual Timer can be programmed to operate two Form C relays 24
hours a day, for an entire year for various applications including security, access control, lighting,
and environmental control. Each relay can be programmed for up to 99 events with each event on
a weekly or daily schedule. Block programming allows events to be repeated on consecutive days.
Twenty programmable holidays disable the timer for a single day or the same day yearly.
• Two N.O. or N.C. Form C relays, 10A@14VDC, with one egress input per relay
• Each relay programmable for 99 events, to a total of 198 individual programmable events
• Each event can be set weekly, daily, or hourly, over the course of an entire year
• Passcode protection can be turned ON or OFF
• Block programming allows events to be repeated on consecutive days
• First-person-in function interrupts the normal operation of the annual timer
• Event outputs can be programmed to disable, ON, OFF, shunt, or momentary (1~99 seconds)
• 20 Programmable holidays
• Tandem mode allows both relays to operate simultaneously
• EEPROM Memory for safe data protection in case of power failure
• Built-in clock backup capacitor (saves date/time 7-10 days after power loss)
• Built-in smart backup battery charger for external backup battery (not included)
• Compensates for leap years and can be set for Standard or Daylight Savings Time.
• Alphanumeric backlit LCD display for easy programming

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SA-027HQ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ENFORCER SA-027HQ

  • Page 1 SA-027HQ Installation Manual The ENFORCER SA-027HQ Annual Timer can be programmed to operate two Form C relays 24 hours a day, for an entire year for various applications including security, access control, lighting, and environmental control. Each relay can be programmed for up to 99 events with each event on a weekly or daily schedule.
  • Page 2: Table Of Contents

    ENFORCER 365-Day Annual Timer Table of Contents Parts List ............2 Setting the Date and Time......7 Overview ............2 Programming Events ........8 Specifications ..........3 Programming Holidays ........9 Installation ............3 Programming Daylight Savings Time ..... 9 Basic Wiring ...........
  • Page 3: Specifications

    ENFORCER 365-Day Annual Timer Specifications Operating voltage 10~48 VDC / 12~24 VAC Number of relays 2 Form C Relay contact rating 10A@14VDC Relay active current draw 60mA@12VDC ±10% (per channel) Standby current draw 14mA@12VDC ±10% Backup battery type 12VDC Lead acid (not included) Battery charge Smart charge, 50mA max., when battery is ≥11.5V and ≤12.8V...
  • Page 4: Basic Wiring

    ENFORCER 365-Day Annual Timer Basic Wiring FM 2 Ground N.O. Ground switch Egress 2 N.C. Device 2 Relay 2 COM N.O. FM 1 N.O. Ground switch Ground Egress 1 N.C. Device 1 Relay 1 COM Lead acid N.O. – backup battery Backup –...
  • Page 5: Programming Introduction

    ENFORCER 365-Day Annual Timer Programming Introduction A convenient feature is the ability to program it before installation. The EEPROM memory stores and protects programming instructions even in case of power failure and after a full charge (about 24 hours) the super capacitor will continue to preserve the correct date and time for 7~10 days after power is lost.
  • Page 6: Programming Menu Flow Chart

    ENFORCER 365-Day Annual Timer Programming Introduction (Continued) Programming Menu Flow Chart When you first apply power to the timer, you will see a startup screen for about 3 seconds followed by a home screen showing the date and time (which you will set later) and a reading of the timer's internal temperature.
  • Page 7: Setting The Display Contrast

    ENFORCER 365-Day Annual Timer Programming (Continued) Setting the Display Contrast Press ENTER to see the Press SEL until following. will be flashing. > S e t D i s p l y < appears. S e t C o n t r a s t >...
  • Page 8: Programming Events

    ENFORCER 365-Day Annual Timer Programming (Continued) Programming Events Press ENTER to see the Choose the relay ( Press SEL until Press ENTER to change, following. > S e t E v e n t s < appears. > R 1 < 0 1 D i s SEL to accept and move on.
  • Page 9: Programming Holidays

    ENFORCER 365-Day Annual Timer Programming (Continued) Programming Holidays Choose holiday # ( Press ENTER to see the Press SEL until 01~20). Press ENTER to following. > S e t H o l i d y < change, SEL to accept and >...
  • Page 10: Programming A Pin Code

    ENFORCER 365-Day Annual Timer Programming (Continued) Programming a PIN Code Press ENTER to see the Press ENTER to change the Press SEL until following. first digit (0~9), SEL to > S e t P i n C o d e <...
  • Page 11: Performing A System Test

    ENFORCER 365-Day Annual Timer Programming (Continued) Performing a System Test Press ENTER to see the Press ENTER to test relay 1. Press SEL until following. Press again to toggle it to its > S y s t e m T e s t <...
  • Page 12: Smart Charging

    ENFORCER 365-Day Annual Timer Smart Charging The timer's smart charging feature controls charging so that the battery is only charged when necessary to prolong the life of the battery and ensure that a battery is not overcharged. When a backup battery is connected, the timer will automatically detect it and start charging if the battery voltage is less than 11.5V.