Parker Balston 72-730 Installation, Operation And Maintenance Manual
Parker Balston 72-730 Installation, Operation And Maintenance Manual

Parker Balston 72-730 Installation, Operation And Maintenance Manual

Oxygen analyzer

Advertisement

Quick Links

Bulletin TI-72730J
Balston
72-730 and 72-O2730NA
®
Oxygen Analyzer
Installation, Operation, and Maintenance Manual
Figure 1 - Front Panel Controls
Description
Sensor
Controls
1-800-343-4048
These instructions must be thoroughly read and understood before installing and oper-
ating this product. Failure to operate this product in accordance with the instructions
set forth in this manual and by other safety governing bodies will void the safety certifi-
cation of this product. If you have any questions or concerns, please call the Technical
Services Department at 800-343-4048, 8AM to 5PM Eastern Time (North America only).
For other locations, please contact your local representative. Send email to:
BalstonTechSupport@Parker.com
The Balston 72-730 and 72-O2730NA Oxygen Analyzers are designed to monitor the oxygen
concentration in a process stream, display this concentration in digital form, and provide
appropriate alarms and controls for protecting a process against undesirable oxygen con-
centrations. The oxygen analyzer is a valuable accessory for food packaging, solvent and
chemical blanketing, and purging applications.
Note: In hazardous applications where the oxygen content is critical (i.e., blanket-
ing explosive chemicals or packaging food for extended shelf life), an oxygen moni-
tor and/or trace oxygen analyzer should be used in conjunction with safety interlocks
and/or alarm systems to assure proper nitrogen purity levels at all times.
The Balston Oxygen Analyzer is a self-contained unit which may be wall-mounted, bench-
mounted, or ordered as an integral accessory to any Nitrogen Generation System. The unit is
powered by 120 VAC or 240 VAC, 50/60Hz. (Note: Main supply voltage must be within 10%
of nominal rated voltage for the generator.)
The Balston oxygen analyzer has been certified to IEC 1010 Standards (CSA 22.2 No.
1010.1-92) and bears the CSA safety marking on the product label.
The sensing device designed into the Balston 72-730 and 72-O2730NA Oxygen Analyzers
is a galvanic cell. The Oxygen Analyzer has an internal temperature compensation circuit to
provide accurate readings within a specified temperature range, with an accuracy of ±1% of
the calibration gas concentration.
The Balston 72-730 and 72-O2730NA Oxygen Analyzers have all the controls necessary to
assure safe and accurate monitoring of the oxygen concentration in a process stream. The
analyzers are equipped with the following controls and features (see Figure 1).
Installation, Operation and Maintenance Manual
72-730 and 72-O730NA Oxygen Analyzer
1
www.labgasgenerators.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Balston 72-730 and is the answer not in the manual?

Questions and answers

Summary of Contents for Parker Balston 72-730

  • Page 1 BalstonTechSupport@Parker.com Description The Balston 72-730 and 72-O2730NA Oxygen Analyzers are designed to monitor the oxygen concentration in a process stream, display this concentration in digital form, and provide appropriate alarms and controls for protecting a process against undesirable oxygen con- centrations.
  • Page 2: Installation

    Sample lines The Balston 72-730 and 72-O2730NA Oxygen Analyzers should be located indoors and as close to the process stream as possible to ensure accurate readings. Do not install the oxygen ana- lyzer outdoors. The location should be clean, dry, and between 59°F and 95°F (15°C - 35°C).
  • Page 3: Voltage Selector

    Operation Calibration The 72-730 and 72-O2730NA are calibrated prior to shipment; however, Parker strongly recom- mends re-calibrating the units prior to initial start-up. After the initial start-up, the unit should be calibrated on a bi-weekly basis until a suitable schedule is determined, based upon the level of accuracy required by the application.
  • Page 4: Alarm Set Points

    (span gas) or 20.9% (compressed air). Close the valve from the calibration gas line and re-open the valve between the process stream and the analyzer. (Note: Parker recommends the use of a span gas with an oxygen content between 1% and 10%.) Alarm set points The high and low limits of the integral alarm may be set anywhere between 0.5% and 25%...
  • Page 5: Maintenance

    “Calibration” section of this manual. If necessary, the Balston 72-730 and 72-O2730NA Oxygen Analyzer may be wiped clean with a dry cloth on an as needed basis. Do not use water, aerosols, or other cleaning agents to clean the unit.
  • Page 6: Replacement Parts

    22172 Galvanic cell (sensor) 72695 Fuse 13221 Cordset 13612 System Specifications Balston 72-730 and 72-O2730NA Oxygen Analyzer CSA Certification Standard CSA 22.2 No. 61010-1-12 IEC 61010 Installation Category Category II IEC 61010 Pollution Category Degree 2 Accuracy ±1% Full scale calibrated span, after 30 min. stabilization Span concentration .1 to 99.9% oxygen...
  • Page 7: Troubleshooting

    (FOR INFORMATION CONTACT YOUR LOCAL REPRESENTATIVE) Parker Hannifin guarantees to the original purchaser of this product, that if the product fails or is defective within 12 months from the date of purchase, when this product is operated and maintained according to the instructions provided with the product, then Parker guarantees, at Parker’s option, to replace the...
  • Page 8 Refer to the caution/warning note indicated for explanation. Caution, risk of electric shock. Parker Hannifin Corporation Parker Hannifin Manufacturing Limited Copyright © Parker Hannifin Corporation 1995, 2015 Gas Separation and Filtration Division EMEA Industrial Gas Filtration and Printed in U.S.A. Bulletin TI-72730J Generation Division Dukesway, Team Valley Trading Estate 4087 Walden Ave.