│OPERATING INSTRUCTIONS MODULE IM4
97, rue de Vaudreuil,
Boucherville (Québec) J4B 1K7
Phone: (450) 449-1499
Fax: (450) 641-4657
Toll-free: 1 877 667-2321
** IMPORTANT **
PLEASE READ PRIOR TO
INSTALLATION AND START UP
97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada
T : 1 877 667-2321 | NORBEC.COM
Date of release : August 2023
1

Advertisement

Table of Contents
loading

Summary of Contents for Norbec IM4

  • Page 1 Fax: (450) 641-4657 Toll-free: 1 877 667-2321 ** IMPORTANT ** PLEASE READ PRIOR TO INSTALLATION AND START UP 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 2: Table Of Contents

    Installation step: Panic Button and temperature sensor ............. 19 APPENDIX 4. Wiring diagram Module IM4 ....................21 APPENDIX 5. Wiring diagram Module IM4 – Remote mounted ............... 22 APPENDIX 6. Wiring Diagram Module IM4 – Surface mounted ..............23 APPENDIX 7.
  • Page 3: Operating And Configuring Instructions

    Those alarms activated minutes external alarm signal (low voltage). [adjustable, see Parameter Descriptions] after 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 4: Panic Alarm

    Dry contact 1. Switch off the module power supply. The dry contact links the IM4 module to an 2. Unscrew the screws holding the keyboard. external alarm system trough a wire. A signal is 3. Lift the keyboard to access the back of the sent to the external alarm when an alarm from the module.
  • Page 5: Alarm Message Descriptions

    (normally closed) from the alarm relay will activate the external alarm signal (low voltage) will be displayed until the alarm condition is reset. 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 6: Display Variables

    Repeat steps 2 to 5 to change additional parameter. Press 3 times to return to the default display. 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 7: Parameters Description

    MON TMP2 LO ALRM -60.0°F 90.0°F point for some time, set low temp2 Freezer: alarm -13°F / -25°C 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 8 CELSIUS Temperature units : Fahrenheit, TEMPERATURE UNITS — CELSIUS FAHRENHEIT Celsius *Disregard for IM4 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 9: Appendix 1

    Position of the proximity sensor in the frame head on the monitor side. This part is not visible and cannot be moved. It is integrated in the frame 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 10 On top of the door, on the monitor side. Possible to unscrew the screw to adjust the height and position of the magnet. 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 11 Installation diagram for a proximity sensor on a sliding door: CL -1750 Installation diagram for a proximity sensor on a hinged door: PL-1750 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 12 │OPERATING INSTRUCTIONS MODULE IM4 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 13: Appendix 2. Installation Step: Im4 Keyboard

    PLEASE REFER TO THE WIRING DIAGRAM FOR THE COMPLETE DIAGRAM. PLEASE REFER TO THE INSTRUCTIONS MANUAL FOR OPERATING AND CONFIGURATION INSTRUCTIONS. 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 14 1. Connect the white cable connector to the receptacle: « NEUTRAL ». 2. Connect the black cable connector to the receptacle: « LINE ». 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 15 4. Insert and screw the stripped end of the red cable into the blue terminal block, in the position: NO 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 16 5. Insert and screw the stripped ends of the cables according to the following connection diagram: New panic Button (2021-10 @ today) 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 17 Dry contact option – Alarm relay 7. Insert and screw the stripped ends of the cables according to the following connection diagram: 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 18 9. Replace the keyboard, making sure that the cables are not to trap and making sure the gasket is in place. 10. Fix the keyboard with the 6 screws provides. 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 19: Appendix 3. Installation Step: Panic Button And Temperature Sensor

    On the inside of the room: 1. Route the panic button assembly wiring trough the top hole to the IM4 junction box. 2. Attache the plate to the inner sheet of the panel, making sure the gasket id in place correctly.
  • Page 20 4. Seal the hole with silicone. 5. Close the hole with the grommet plug to contain the excess silicone. 6. Connect the panic button wiring to the IM4 monitor terminal block. 7. Repeat steps 3 to 5 for the temperature sensor.
  • Page 21: Appendix 4. Wiring Diagram Module Im4

    │OPERATING INSTRUCTIONS MODULE IM4 APPENDIX 4. Wiring diagram Module IM4 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 22: Appendix 5. Wiring Diagram Module Im4 - Remote Mounted

    │OPERATING INSTRUCTIONS MODULE IM4 APPENDIX 5. Wiring diagram Module IM4 – Remote mounted 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 23: Appendix 6. Wiring Diagram Module Im4 - Surface Mounted

    │OPERATING INSTRUCTIONS MODULE IM4 APPENDIX 6. Wiring Diagram Module IM4 – Surface mounted 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 24 │OPERATING INSTRUCTIONS MODULE IM4 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...
  • Page 25: Appendix 7.

    2) Once the probe went through the hole, fill the hole with silicon and install the remaining parts included in the 97, rue de Vaudreuil Boucherville (Quebec) J4B 1K7 Canada T : 1 877 667-2321 | NORBEC.COM Date of release : August 2023...