NoiseKen THA-380M60G Instruction Manual

Tem horn antenna

Advertisement

Quick Links

INSTRUCTION MANUAL
TEM horn antenna
THA-380M60G
MODEL
NOISE LABORATORY CO., LTD.
Edition 1.01
AEY00105-00E-0

Advertisement

Table of Contents
loading

Summary of Contents for NoiseKen THA-380M60G

  • Page 1 INSTRUCTION MANUAL TEM horn antenna THA-380M60G MODEL NOISE LABORATORY CO., LTD. Edition 1.01 AEY00105-00E-0...
  • Page 2 NOTICE The contents of this instruction manual (the “Manual”) are subject to change without prior • notice. No part of the Manual may be reproduced or distributed, in any form or by any means, • without the authorization of Noise Laboratory Co., Ltd. (the “Company”). The contents of the Manual have been thoroughly examined.
  • Page 3: Important Safety Precautions

    1. IMPORTANT SAFETY PRECAUTIONS The "Important Safety Precautions" explain rules that must be followed to prevent any risk of harm or injury to the user of the instrument or to other people. The instrument may only be used by trained EMC technicians (electrical technicians) Failure to follow this rule risks death or serious injury.
  • Page 4 Memorandum...
  • Page 5: Application Form For Instruction Manual

    2. APPLICATION FORM FOR INSTRUCTION MANUAL To: Noise Laboratory Co., Ltd. via sales agent We place an order for an instruction manual. Model Name THA-380M60G Serial No. Applicant Address Company Name Department Contact Person Phone No. FAX No. Cut off this page "PURCHASE ORDER FOR INSTRUCTION MANUAL"...
  • Page 6 Memorandum...
  • Page 7: Table Of Contents

    3. TABLE OF CONTENTS IMPORTANT SAFETY PRECAUTIONS ..................1 APPLICATION FORM FOR INSTRUCTION MANUAL ............3 TABLE OF CONTENTS ....................... 5 INTRODUCTION ......................... 6 BASIC SAFETY PRECAUTIONS ....................7 Safety Warning Signs and Their Meanings .................... 7 Basic Safety Precautions ........................7 PRODUCT COMPONENTS ......................
  • Page 8: Introduction

    4. INTRODUCTION We thank you very much for your purchase of the TEM horn antenna Model: THA-380M60G. It is recommended that the contents of this manual be thoroughly understood and used as a ready reference for operation. This Instruction Manual was prepared so that any person who can observe the prescribed instruction method and operating precautions may safely handle and fully utilize this THA-380M60G.
  • Page 9: Basic Safety Precautions

    5. BASIC SAFETY PRECAUTIONS Safety Warning Signs and Their Meanings Indicates Warning. Failure to follow this safety information can lead to a potentially hazardous situation resulting in death or serious injury. Indicates Caution. Failure to follow this safety information can lead to a potentially hazardous situation resulting in a minor injury or moderate damage.
  • Page 10 BASIC SAFETY PRECAUTIONS Avoid using the unit in locations with high humidity or exposed to large amounts of dust. Failure to observe this can damage the unit and result in impaired performance. (Precaution regarding environment) Any required repairs, maintenance, and internal adjustment for this unit must be performed only by service engineers authorized by Noise Laboratory.
  • Page 11: Product Components

    6. PRODUCT COMPONENTS Main Unit (THA-380M60G) Instruction Manual (this document)
  • Page 12: Appearance And Function Of Each Part

    7. APPEARANCE AND FUNCTION OF EACH PART 7-1. Appearance of the Main Unit φ22 Antenna support pole Antenna rear panel 7-2. Antenna rear panel INPUT Connector【RF INPUT】 Use by connecting a high frequency power amplifier to the RF INPUT. Input connector is N connector (female). Power can be input up to 180 W from 380 MHz to less than 750 MHz, 100 W from 750 MHz to less than 1.7 GHz, and 65 W from 1.7 GHz to 6 GHz.
  • Page 13: Operation

    8. OPERATION Connect the coaxial cable to the RF INPUT (N connector) of this product. The center of the cross in front of the TEM horn antenna is the maximum point of the near electric field distribution. Refer to 9-3. Electric field distribution characteristics and check the uniform area of 0 to -4 dB before use.
  • Page 14: Characteristic Data

    9. CHARACTERISTIC DATA 9-1. VSWR (typ.) 9-2. Input Power for 300V/m at 0.1m (typ.)
  • Page 15: Electric Field Distribution Characteristics At 0.1M (Typical)

    CHARACTERISTIC DATA 9-3. Electric field distribution characteristics at 0.1m (typical) It is an electric field distribution map of each frequency at a distance of 0.1 m from the antenna element. The electric field distribution map in the figure is for vertically polarization. The contour lines in the figure are drawn every -2dB.
  • Page 16 CHARACTERISTIC DATA 1455 MHz 1845 MHz 0.000 0.000 -2.000 -2.000 -4.000 -4.000 -6.000 -6.000 -8.000 -8.000 -10.00 -10.00 -12.00 -12.00 -14.00 -14.00 -100 -100 -16.00 -16.00 -150 -150 -18.00 -18.00 -20.00 -20.00 -200 -200 -200 -150 -100 -200 -150 -100 X [mm] X [mm] 5500 MHz...
  • Page 17: Antenna Radiation Pattern (Typ.)

    CHARACTERISTIC DATA 9-4. Antenna Radiation Pattern (typ.) E-Plane 380MHz -3dB Measurement 1000MHz -3dB Measurement...
  • Page 18 CHARACTERISTIC DATA 2000MHz -3dB Measurement 3000MHz -3dB Measurement...
  • Page 19 CHARACTERISTIC DATA 4000MHz -3dB Measurement 5000MHz -3dB Measurement...
  • Page 20 CHARACTERISTIC DATA 6000MHz -3dB Measurement...
  • Page 21 CHARACTERISTIC DATA H-Plane 380MHz -3dB Measurement 1000MHz -3dB Measurement...
  • Page 22 CHARACTERISTIC DATA 2000MHz -3dB Measurement 3000MHz -3dB Measurement...
  • Page 23 CHARACTERISTIC DATA 4000MHz -3dB Measurement 5000MHz -3dB Measurement...
  • Page 24: Antenna Gain (Typ.)

    CHARACTERISTIC DATA 6000MHz -3dB Measurement 9-5. Antenna Gain (typ.)
  • Page 25: Specifications

    SPECIFICATIONS Item Spec./Performance Application IEC 61000-4-39 380 MHz ~ 6.0 GHz Frequency range VSWR 3.0 or less 380 MHz ~ 750 MHz:180 W MAX 750 MHz ~ 1.7 GHz:100 W MAX Power input 1.7 GHz ~ 6.0 GHz: 65 W MAX Gain Refer to 9-2.
  • Page 26: Warranty

    11. WARRANTY Servicing terms The following terms are applicable to servicing by Noise Laboratory Co., Ltd., (hereafter referred to as the Company) provided to maintain the intended performance of its products. Scope The following terms shall apply only to products made by the Company. If the user or unauthorized service person should open the cover or case of the product which cannot be allowed to open, this warranty prescription becomes ineffective.
  • Page 27 WARRANTY Limited Warranty Noise Laboratory Co., Ltd. (hereafter referred to as the Company) warrants its products to be free from defects in materials and workmanship under normal use and service for a period of one year from date of delivery. In the event of failure of a product covered by this warranty, the Company will repair the product or may, at its option, replace it in lieu of repair without charge.
  • Page 28: Maintenance

    12. MAINTENANCE When repair, maintenance or internal adjustment of the unit is required, a qualified service engineer takes charge of such work. Maintenance on the user side is restricted to the outside cleaning and functional check of the unit. When checking or replacing the fuse, turn off the switch of the unit and disconnect the plug socket beforehand.
  • Page 29: Contacting Technical Support

    When it is necessary to send your unit back to Noise Laboratory, fill in the repair order form completely, pack the unit in the original package or equivalent one suitable for transit, and send the package. □ Customer Service Center TEL +81-42-712-2051 FAX +81-42-712-2050 E-mail:sales@noiseken.com...
  • Page 30 NOISE LABORATORY CO., LTD. 1-4-4, Chiyoda, Chuo-ku, Sagamihara City, Kanagawa Pref., 252-0237, Japan TEL: +81-(0)42-712-2051 FAX: +81-(0)42-712-2050 URL: http://www.noiseken.co.jp Printed in Japan...

Table of Contents