  • Page 1 AIR CONDITIONER USER MANUAL ST4802 INVERTER FREE-STANDING AIR CONDITIONER...
  • Page 2 • The air conditioner must be mounted by Vestel Authorised Service. • The air conditioner must be grounded.
  • Page 3: Table Of Contents

    Contents Safety Warnings ..............1 Safety Information for Installing the Appliance ....1 Safety Information to be Considered when Using the Appliance Safety Information to be Considered when Performing Cleaning and Maintenance Procedures ..........7 Batteries ..............7 Points to be Considered during Carrying and Transportation .7 Liability Limitation ............
  • Page 4: Safety Warnings

    • WARNING: In the event should be installed. that your air conditioner is • WARNING: The appliance connected permanently to should be mounted by Vestel a fixed installation and has Authorized Service according a leakage current that may to “Mounting Instructions”.
  • Page 5 • WARNING: To connect the select an altitude of less than 2000 meters above sea appliance to the power supply level in terms of insulation and for the connection of the distances. inner parts, see the wiring diagram on the appliance. •...
  • Page 6: Safety Information To Be Considered When Using The Appliance

    m a d e b y u n a u t h o r i z e d cool airflow coming out of the air personnel. conditioner in any way. Set the direction of the airflow in such a Safety Information to way that it does not blow directly be Considered when onto persons.
  • Page 7 • Air flow should not be directed consuming device on the to the stove; otherwise, the same circuit. Do not connect stove may not burn properly with extension cables or and cause danger. multi plugs. If you neglect, it may cause electric shocks or •...
  • Page 8 between indoors and outdoors • Never use your appliance at about 5°C. under following circumstances: - If the appliance or the power • Packaging materials are dangerous for children. Keep cord is damaged, all packaging materials out of - If the appliance is dropped, the reach of children.
  • Page 9 appliance, do not attempt to in which the appliance is, repair it yourself. Otherwise, close the gas and the air the appliance will be out of conditioner. Do not restart warranty. the air conditioner before ventilating the environment • U s e a c c e s s o r i e s completely.
  • Page 10: Safety Information To Be Considered When Performing Cleaning And Maintenance Procedures

    - Before repair works. the external appearance of the air conditioner. • Do not drink the water drained from the product. Otherwise, • Insert the air filter after it gets severe health problems may dry completely. Operating the occur. appliance without filters may cause breakdowns.
  • Page 11: Liability Limitation

    Technical use, unauthorized repairs, Specifications Product Brand Vestel ST4802 INVERTER FREE-STANDING Model AIR CONDITIONER Electrical Input Outdoor Unit (Ø /V /Hz) 3Ø, 380-415V, 50Hz Electrical Input Indoor Unit (Ø /V /Hz) 220-240V, 50Hz...
  • Page 12: General Appearance

    Indoor Unit Operating Temperature Range 16 / 30 (Cooling) (°C) Indoor Unit Operating Temperature Range 16 / 30 (Heating) (°C) Cooling Current Rating / Heating Current 8.8 - 7.3 Rating (A) Climate Class Electric Shock Protection Class 1 Refrigerant Weight-Dimension Net Weight (Indoor Unit) (kg) Net Weight (Outdoor Unit) (kg) Net Dimensions (Indoor Unit) ( W x H x D) (mm)
  • Page 13: Outdoor Unit

    1. Air Outlet (Blows the set air) 2. Horizontal Fin 3. Vertical Fin • Used to adjust the set temperature. 4. Control Panel • Each time the "+" button is pressed, the temperature increases by 1ºC. 5. Air Inlet Grille (Left and Right) •...
  • Page 14: Remote Control

    The electric heater indicator lights up 7 meters away from the receiver. when the electric heater operates in • There should not be any obstacle heating mode. (Applies to models with a between the remote control and the built-in electric heater.) receiver.
  • Page 15 On/Off Button Mode Button Fan Speed Button Room Temperature Adjustment Buttons Turbo Mode Button Up/Down Swing Button Right/Left Swing Button Smart Mode Button Sleep Mode Button Feel Mode Button Clock Adjustment Button Timer Button (Used for Automatic Turn On of the Appliance) Timer Button (Used for Automatic Turn Off of the Appliance) Silent Mode Button Indoor Unit Display Light Button...
  • Page 16 MODE BUTTON TURBO BUTTON For selecting the operation mode. Each When you press this button, the appliance time this button is pressed, the operating operates in "TURBO" mode. The "TURBO" mode changes respectively to "Automatic- mode is used to start or stop the fast Cooling-Dehumidification-Fan-Heating".
  • Page 17 When you press the "SMART MODE" then keeps steady. button, the unit directly enters the Note: In cooling mode, if room temperature "SMART" mode, regardless of whether it is is 26°C or above, set temperature will not on or off. In this mode, temperature and change (not applicable for all models).
  • Page 18 • Press the "CLOCK" button again to ON" button, the remote control will save the time you set. automatically exit the "TIMER" mode. • When the desired time is displayed on TIMER BUTTON (USED FOR the LCD, verify the time by pressing AUTOMATIC TURN ON OF the "TIMER ON"...
  • Page 19: Applications Regarding Usage

    • When the desired time is displayed on remote control. the LCD, verify the time by pressing Operation modes the "TIMER OFF" button. Cancelling The air conditioner can be used in 4 the timer function: different operating modes. • Press the "TIMER OFF" button again. Automatic ( ) Operation Mode A "beep"...
  • Page 20 compressor stops working. changes as you press the button. NOTE: The heating capacity depends on 4. You can set the fan speed to AUTO, external factors, such as the temperature LOW, MEDIUM or HIGH by pressing the of the outdoor air. If the outdoor "FAN SPEED ADJUSTMENT"...
  • Page 21: Cleaning And Maintenance

    facilitate the circulation of air in the room, performance. When this happens, a since hot air will be collected above. When defrosting system of the air conditioner carrying out heating, the direction should will operate. At the same time, the fan be turned downwards to facilitate the of the indoor unit stops (or in some cases circulation of air in the room, since cold...
  • Page 22: Cleaning The Air Filter

    The panel of the indoor unit can be removed. After cleaning, dry it with a dry cloth. NOTE: Never use volatile substances such as gasoline and polishing powder to clean the appliance. NOTE: Never splash water on the indoor unit. NOTE: On a day when the weather is good, run the device in "FAN"...
  • Page 23: Installation

    Installation over the cables. Failure to attach the sheaths may cause the terminal to WARNING: The air conditioner should overheat, electric shock, or fire.) be installed by Vessel Authorized Service • When installing or relocating the in accordance with the “Installation system, be sure to keep the refrigerant Instructions”.
  • Page 24 outdoor unit, please be careful, do shall be fastened with expansion bolt. not make the outdoor unit incline over Ensure the secure installation regardless of what type of wall on which it is 45 degree. installed, to prevent potential dropping •...
  • Page 25: Indoor Unit

    Indoor unit • There should not be any vapour or heat source near the air conditioner. During installation, do not damage the • There should not be any obstacle insulation material on the surface of the preventing air circulation at the indoor unit.
  • Page 26 Max.Pipe Max.Drop Length(m) Height (L) (m) Outdoor Unit Indoor unit H o l e d i a m e t e r f o r installation bolts: d Indoor unit • Hole to be drilled into the wall for Maximum Pipe Length connecting pipe connections to the outdoor unit;...
  • Page 27 hands at first, then tighten with torque wrenches. Connecting pipes Bağlantı boruları • Pay attention to the allowed torque as shown on table to prevent the pipes, connectors and flared nuts from being deformed and damaged. Pipe Diameter (mm) Torque (N.m) Φ...
  • Page 28 (küçük) (büyük) (large) (small) must be completely discharged by Konik Flared nuts somunlar the Vestel Authorized Service Center Torque wrench Tork anahtarı Konnektörler in accordance with the "Installation Connectors Instructions". Charge Additional Refrigerant 3 Yollu valf...
  • Page 29 with a good anchor. Vidalar( ST4×12 Screws(ST4x12) Düşme önleyici - Grounding should be done for both the Anti-fall plate Çelik çivi Steel nail indoor and outdoor unit. - Reattach the components you removed Duvar to the unit. Wall Wiring Connection İç...
  • Page 30 than the ordinary polychloroprene to a gas pipe, water pipe, lightning sheathed flexible cord. (Cord rod, telephone line, or a circuit poorly grounded to the earth. designation H07RN-F). • The wire sizes marked with *1 in • The grounding wire is specially the above table are selected at the designed and shall not be used for maximum current of the unit according...
  • Page 31 Cable Wiring Diagram Dış Ünite İç Ünite Terminali Terminali Outdoor Unit Terminal Indoor Unit Terminal İç-Dış ünite Indoor-Outdoor unit iletim kablosu transmission cable Power Supply Güç Kaynağı Internal Connection Diagram of Appliance Heating/Cooling Mode Components İÇ ÜNİTE DIŞ ÜNİTE OUTDOOR UNIT INDOOR UNIT Gaz borusu Gas pipe...
  • Page 32: Troubleshooting

    Service Information the circuit breaker of the device. Please System created by the Ministry. contact Vestel Contact Center. You may SOLUTION PROBLEM Operating light or other indicator lights Contact Vestel Authorized Service.
  • Page 33 PROBLEM CAUSE SOLUTION Does not start Compressor has a 3-minute Wait. immediately protection function. While the system is being Refrigerant flow started or stopped, sound This is not a fault. sound from the refrigerant flow may be heard. Caused by the expansion Crackling sound o r c o n t ra c t i o n o f t h e This is not a fault.
  • Page 34 NOTE: To avoid danger, do not try to normal for steam to come out of repair the air conditioner or change the the outdoor unit. electric cable by yourself. 2)White steam comes out from the indoor b) The situations that do not indicate a unit fault: During defrosting process, if the humidity...
  • Page 35 Disposal of the Appliance in an temperature increases or decreases to a Environmental Friendly Manner certain degree, the compressor will start heating or cooling process again. This marking either on the 7)If you choose cooling mode in a humid product or the information environment (relative humidity over 8%), label indicates that this evaporation may occur on the surface...
  • Page 36: Recommendations On Energy Saving

    totally recyclable. Do not discard are not clogged; otherwise, the air packaging material with household or conditioner's performance may reduce other wastes, discard it to packaging or it may stop. material collecting point determined • Clean the air filter regularly. Otherwise by local government.