Fig.37
Typical electrical connections
A
E
L
N
Key
Description
A
Fused Spur
B
Room Thermostat
C
External Clock
D
Frost Thermostat
F
Pipe Thermostat
G
Mains Terminal Block M1
H
Low Voltage Terminal Block M2
7679306 - 1 - 10082017
N
B
G
230V
E
N
L
A
E
L
N
b
1
bk
2
g/y
b
br
5. Connect the earth, permanent live and neutral wires to the terminal
block.
Note
Both the permanent live and neutral connections are fused.
Key
Description
b
Blue
bk
Black
br
Brown
g/y
Green/Yellow
E
Earth
N
Neutral
L
Live
6. Refer to the instructions supplied with the external control(s).
7. Remove the link between terminals 1 and 2.
8. The 230V supply at terminal 2 must be connected to the thermostat.
9. The switched output from the thermostat must be connect to termi­
nal 1.
Important
The 230V switched signal for external controls (frost thermostat —
room thermostat — timer) must always be taken from terminal 2 at
the boiler. Live, Neutral and Earth to power these controls must be
taken from the Fused Spur.
10. Reclip the terminal block cover back into position and hinge back the
control box.
Important
When an OpenTherm controller is connected adjustment of the
boiler, e.g. heating temperature, is made using the OpenTherm
controller rather than the boiler controls. The boiler controls are
overridden by the OpenTherm control. Please check the function­
ality with the manufacturer of the OpenTherm controller.
Preliminary electrical checks
Prior to commissioning the boiler preliminary electrical system checks
should be carried out.
D
F
B
230V
N
G
230V
E
C
N
L
6 Installation
b
1
bk
2
g/y
b
br
PN-0000396
43