Instructions for use DIAGNOdent display 2191 Table of contents Table of contents 1 User instructions ....................... 2 Safety..........................2.1 Infection hazard ......................6 2.2 Explosion hazard ......................6 2.3 Technical condition ......................6 2.4 Electromagnetic fields ....................7 2.5 Accessories and combination with other equipment............7 2.6 Qualification of personnel ....................
Dental GmbH. All other trademarks are property of their respective owners. KaVo Original Factory Repair In the event of a repair, please ship your product to the KaVo Original Factory Repair using www.kavobox.com. KaVo Technical Service If you have any technical questions or complaints, please contact the KaVo...
Page 5
Instructions for use DIAGNOdent display 2191 1 User instructions Hazard levels The warning and safety notes in this document must be observed to prevent personal injury and material damage. The warning notes are designated as shown below: HAZARD In cases which – if not prevented – directly lead to death or severe injury. WARNING In cases which –...
Instructions for use DIAGNOdent display 2191 2 Safety | 2.1 Infection hazard 2 Safety NOTE All serious events occurring in relation to the product must be reported to the manufacturer and the competent authority of the member state, in which the user and/or patient resides.
4 Observe national and regional regulations. 2.7 Service and repair The following persons are authorised to repair and service the KaVo product: ▪ Service technicians of KaVo branches after the appropriate product training ▪ Service technicians of KaVo authorised dealers after the appropriate product...
§ 6 of the operator ordinance ("MPBetreiberV"). As a result of the use of NON-KaVo original spare parts during the repair, parts may become detached and injure patients, users or third parties. This may res- ult in aspiration, swallowing of parts and possibly even a risk of suffocation.
Instructions for use DIAGNOdent display 2191 3 Description of the product | 3.1 DIAGNOdent display 2191 3 Description of the product 3.1 DIAGNOdent display 2191 ① Infrared receiver ④ Volume button ② ON/OFF button ⑤ Key to display brightness ③ Table holder for DIAGNOdent pen 2190 9 / 32...
The overarching guidelines and/or national laws, national regulations and the rules of technology applicable to this product for putting into service and use of the KaVo product for the indications for use are to be applied and complied with. 10 / 32...
Instructions for use DIAGNOdent display 2191 3 Description of the product | 3.3 Symbols on product, packaging and rating plate This KaVo product is intended for use in dentistry only. Any other type of use is not permitted. The intended use also includes compliance with all notes provided in the in- structions for use as well as compliance with prescribed inspections and main- tenance.
Page 12
Instructions for use DIAGNOdent display 2191 3 Description of the product | 3.3 Symbols on product, packaging and rating plate Follow instructions for use Follow the electronic instructions for use HIBC Code Certification CE- mark (European Community). A product bearing this mark meets the requirements of the applicable EC directives.
Instructions for use DIAGNOdent display 2191 3 Description of the product | 3.4 Technical Specifications Transportation and storage conditions (Humidity) Protect from moisture (Keep dry) Protect from impact Permissible stacking load 3.4 Technical Specifications Length approx. 17.5 cm Width approx.10.5 cm Altitude approx.
Terms and Conditions, Art. 28). Outside Germany NOTE KaVo shall not be held liable for damage arising from transportation. The shipment must be checked on arrival. If the packaging is visibly damaged on delivery, please proceed as follows: 1. The recipient of the package must record the loss or damage on the delivery receipt.
Instructions for use DIAGNOdent display 2191 4 Startup | 4.1 Insert batteries 4 Startup WARNING Hazard from contaminated products. Infection hazard to the dentist and patient. 4 Prior to initial startup and after each use, reprocess the product and ac- cessories.
Page 16
Instructions for use DIAGNOdent display 2191 4 Startup | 4.1 Insert batteries 4 Slide the DIAGNOdent display 2191 into the side of the table holder ①. DIAGNOdent display 2191 push forwards in the direction of the arrow ②. 16 / 32...
Page 17
Instructions for use DIAGNOdent display 2191 4 Startup | 4.1 Insert batteries 17 / 32...
Instructions for use DIAGNOdent display 2191 5 Operation | 5.1 Start up 5 Operation CAUTION Risks from electromagnetic fields. Electromagnetic fields might interfere with the functions of implanted systems (such as pacemakers). 4 Do not use the device on a patient with implanted systems. 5.1 Start up 4 Briefly press the ON-OFF button ①.
Instructions for use DIAGNOdent display 2191 5 Operation | 5.2 Turn off 5.2 Turn off 4 Press the ON-OFF button ① for 5 seconds. ð If no data is received within 90 seconds, the DIAGNOdent display 2191 switches off by itself. ð...
Page 20
Instructions for use DIAGNOdent display 2191 5 Operation | 5.2 Turn off 20 / 32...
Instructions for use DIAGNOdent display 2191 5 Operation | 5.3 Display brightness 5.3 Display brightness 4 Press the brightness button with a pin (diameter < 2 mm)①. ð The display brightness can be set in 3 brightness levels. ð If no infrared signals are sent, the display goes dark to save energy. ð...
Instructions for use DIAGNOdent display 2191 5 Operation | 5.5 Battery charge display 5.5 Battery charge display The battery charge is good The battery charge is sufficient Replace the batteries Independent shut-off of the DIAGNOdent display 2191 because the battery charge is too low. Replace the batteries 5.6 Reception quality Optimum infrared connection between...
Instructions for use DIAGNOdent display 2191 5 Operation | 5.7 Bar display of MOMENT and PEAK value 5.7 Bar display of MOMENT and PEAK value The MOMENT and PEAK values are displayed as a bar in addition to the numeric display.
KaVo spare parts comply with the specification. NOTE If a repair is done with NON-KaVo original spare parts, this may constitute a product modification that leads to the loss of CE conformity. In the event of damage, the responsibility is with the service company or the operator.
Never reprocess the device in an ultrasonic cleaner. Malfunction and material damage. KaVo recommends the following products based on the compatibility of the ma- terials. The microbiological efficacy must be ensured by the disinfectant manu- facturer and proven by an expert opinion.
Instructions for use DIAGNOdent display 2191 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.3 Automated reprocessing 4 Follow the instructions for use of the disinfectant. 7.2.4 Manual internal disinfection This product is not designed for manual internal disinfection. 7.2.5 Manual drying This product is not designed for manual drying.
4 Insert new batteries. Symbol: battery flat. No display indication. Display is defective. 4 Send the device to KaVo for repair. Long tone after the start tone. 4 If this error occurs repeatedly, send the Display indication: The data transmission to Oled: error the display is flawed.
If you have any questions regarding the proper disposal of the KaVo product, please contact the KaVo branch office. Disposal of electronic and electrical devices...
Instructions for use DIAGNOdent display 2191 10 Information about electromagnetic compatibility | 10.1 Operating environment and EMC warning notes 10 Information about electromagnetic compatibility 10.1 Operating environment and EMC warning notes This product is neither life-sustaining nor coupled to the patient. It is suitable, in terms of EMC, for operation both in domestic healthcare and in facilities used for medical purposes except in the vicinity of active facilities of HF surgery devices or in rooms/areas, in which EMC interference of high-intensity may oc-...
Page 30
Instructions for use DIAGNOdent display 2191 10 Information about electromagnetic compatibility | 10.2 Results of the electromagnetic tests Requirement Class / test level Immunity to electromagnetic interference DIN EN 61000-4-2 VDE 0847-4-2 / 12.2009 Discharge of static electricity (ESD) Atmospheric discharge ±...
12 months from the date of the invoice, subject to the following conditions: With regard to justified complaints KaVo grants warranty in the form of a free of charge repair or delivery of a replacement. Other claims of any kind whatso- ever, in particular with respect to compensation, are excluded.
Need help?
Do you have a question about the DIAGNOdent 2191 and is the answer not in the manual?
Questions and answers