Graco 970019 Instructions-Parts List Manual page 11

55 gallon, 65:1 quiet king module supply units
Table of Contents

Advertisement

Low–Level Shutoff Setup (Model 970021)
Setup the low–level shutoff as shown in Fig. 5.
During system operation, as the ram approaches the
drum bottom, the top of the ram contacts the limit
switch. The switch shuts off the air to the ram.
KEY
1
3–Way Pilot Valve
2
Air Limit Valve
3
Limit Valve Bracket
4
Breather Vent
5
Pipe Cross Fitting
Fig. 5
System Setup
Low–Level Shutoff Setup (Model 970021)
NOTE: The position of the air limit valve (2) on the
ram determines when the ram air motor is turned on
and off. During operation, this position can be adjusted
as desired. See Fig. 5.
2
3
5
1
A
4
1 REF
Detail A
8586A
11
310309