Page 1
* These models are CE certified. Read warnings and instructions. See page 2 for model numbers and Related Manuals. Model 970019 Tandem Shown 8642A GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 Copyright 1998, Graco Inc. is registered to I.S. EN ISO 9001...
Maximum Fluid Maximum Pump Parts Part No. Pump Model Pump Model Ratio Working Pressure Air Input Pressure Page * 970019 Quiet Kingt Check-Matet 800 65:1 336 bar, 33.6 MPa 5.2 bar, 0.52 MPa (4875 psi) (75 psi) 970020 Quiet Kingt...
D This equipment is for professional use only. D Read all instruction manuals, warnings, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor.
Page 4
WARNING INJECTION HAZARD Spray from the spray gun, hose leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Splashing fluid in the eyes or on the skin can also cause serious injury. D Fluid injected into the skin might look like just a cut, but it is a serious injury.
Page 5
WARNING MOVING PARTS HAZARD Moving parts, such as the ram follower plate/pump inlet can pinch fingers. D Do not operate the equipment with the guard removed. D Keep clear of all moving parts when starting or operating the equipment. D Keep hands and fingers away from the priming piston during operation and whenever the pump is charged with air.
(Refer to the preceding WARNING ). When closed, Model 970019 includes a dual 55 gallon supply unit the valve bleeds off all air in the ram and pump, and with pneumatic crossover for continuous material the ram slowly lowers.
Component Identification and Function Pump Pump Air Bleed Valve Ball Valve Ram (two used on 970019 and 970020; (required, for pump) Ram Air Regulator one used on 970021) Air Line Filter Ram Director Valve Ram Plate Bleed-Type Air Valve Air Release Valve...
(Y) into slot in lug (Z) and accessories. Contact your Graco distributor for help in tighten locknut securely. Connect other end of wire designing a system to suit your particular needs.
Page 9
4–way piloted air valve (3). As the valve stops air to one ram, it starts air to the other ram. This allows constant material flow and changing out of material drums. Pneumatic Crossover Setup (Model 970019) Ball Valves (2) Regulator 4–Way Piloted Air Valve...
Page 10
System Setup Electrical Crossover Setup (Model 970020) The position of the empty level indicator kit (2) on the ram determines when the ram air motor is turned on and off. During operation, this position can be adjusted The electrical crossover is setup as shown in Fig. 4 as desired.
Page 11
System Setup Low–Level Shutoff Setup (Model 970021) NOTE: The position of the air limit valve (2) on the ram determines when the ram air motor is turned on Setup the low–level shutoff as shown in Fig. 5. and off. During operation, this position can be adjusted During system operation, as the ram approaches the as desired.
(DD), having a eliminates factory-test oil from system. If neces- container ready to catch the drainage. sary, check with Graco Distributor or material sup- plier for recommended solvent. 8. Leave the drain valve open until you are ready to spray/dispense again.
Page 14
Operation Model 970019 Tandem Ram Shown 05698B 8320B Fig. 6 310309...
Operation Starting and Adjusting System Rams CAUTION To help avoid damage to equipment, do not use WARNING drums that have side bungs or large dents with this ram. Rough bung openings or large dents will dam- PRESSURIZED EQUIPMENT HAZARD age the wipers or stop the ram plate, resulting in a To reduce risk of injury or equipment runaway pump.
Page 16
Operation Changing Drums 6. Inspect wiper plate and, if necessary, remove any remaining material or material build–up. WARNING Place full drum on ram base. MOVING PARTS HAZARD 8. Lubricate wipers. Moving parts can pinch or amputate your fingers. When the pump is operating and 9.
Page 17
Parts Model 970019 Tandem with Pneumatic Crossover, 65:1 Ratio Quiet King Pump Includes items 1–7 2 REF. Ref. No. 3 Fluid Supply Hose Includes Items 4–7 8322A Part Part Description Description C59521 PUMP, ram–mounted 200 liter (55 gal.) 521973 . HOSE...
Page 18
Parts Model 970020 Tandem with Electrical Crossover, 65:1 Ratio Quiet King Pump Includes items 1–7 Ref. No. 2 Electrical Crossover Kit 7 6 5 4 Ref. No. 3 Fluid Supply Hose Includes Items 4–7 8322A Part Part Description Description C59521 PUMP, ram–mounted 200 liter (55 gal.) 521973 .
Page 19
Parts Model 970021 Supply Unit with Pneumatic Low Level Shut–Off, 65:1 Ratio Quiet King Pump Includes items 1–7 Ref. No. 3 Fluid Supply Hose Includes Items 4–7 Part Part Description Description C59521 PUMP, ram–mounted 200 liter (55 gal.) 521973 . HOSE ASSEMBLY See 308027 for parts 521975 .
Page 20
Ram Mounted Pump Clearance Dimensions Model 970019 Ram Shown 14.2 mm (0.56 in.) Diameter Holes 8320B Model (Raised) (Lowered) 2578 mm 1575 mm 533 mm 635 mm 965 mm 1067 mm 1111 mm (101.5 in.) (62 in.) (21 in.) (25 in.) (38 in.)