Indicator Lights - Uni-P Dry Uni-P Pro 120X Installation, Operation & Service Instructions

Table of Contents

Advertisement

Uni-P Pro 120X Dehumidifier
3.Continuous Mode

To set the unit to run continuously regardless of humidity, simply use the down arrow
key to set the humidity below 36%.

The continuous light will illuminate green and the display will show"CO"

To switch back to normal humidistat operation, use the arrow keys to move the setpoint above
36%.
4.Manual Drain Button

If you need to store or move your dehumidifier, press the "Drain" button to remove water
from the integral pump's reservoir.
5. Pump Trouble Warning

If the pump reservoir level gets too high, the water sensor will activate to prevent overflow.

When this occurs, the compressor will stop automatically, and the display will show "E4".
After a 1 minute delay, the fan motor will turn off and the dehumidifier will not operate until the
problem has been resolved.

Check to verify that the pump is functioning, then unplug the unit for. two minutes to reset the
error code.
6. Auxillary Terminals A5/A6
• The A5/A6 on the terminal strip can be used as a safety switch for an external float switch.
• It should be set to N/O (normally open) at the accessory float switch.
• If an E4 error occurs immediately , switch the wiring to N/C (normally closed) on external switch.
You may need to unplug the unit to reset the error code.
Tel: 888-994-0895
Installation, Operation & Service Instructions
.
4
Uni-P Pro 120X Dehumidifier

Indicator Lights

1. Humidity Display Screen
• The display screen has two functions:
1. When the unit is powered on, it shows the humidity of the space.
2. When setting the desired humidity level, the screen will show the set point. After a brief
delay, it will revert to current humidity of the space.
2. Power Indicator Light
This light indicates that the unit is properly powered on and ready to operate.
• Always make sure the unit is "off" prior to performing any service, unless otherwise
indicated.
• If the humidity is above the setpoint, the light will be solid green and the machine will
operate.
• If the humidity is below the setpoint, the unit will be in standby mode and the light will
be flashing.
.
3
Continuous Mode/ Auto Defrost Light
• When the light illuminates green, it indicates that the dehumidifier is set to continuous
operation mode.
• When the light illuminates red, it means the unit is in auto defrost mode and clearing
the evaporator coils of any ice buildup.
.
4
Compressor Light
• When the light illuminates red, it indicates the compressor has been initiated but is
currently warming up.
• Once the light switches to green, it means the compressor is currently in working status.
5