  • Page 1 WRCAN60RF WRCAN90RF User Manual WRCAN60 & 90RF Hood IM V2 MAY.indd 1 WRCAN60 & 90RF Hood IM V2 MAY.indd 1 25/05/2022 15:49 25/05/2022 15:49...
  • Page 2: Table Of Contents

    Contents | Before you start | Safety | Electrical installation | Technical data | Troubleshooting | Guarantee | What's required for installation | What's in the box | Installation | Connectivity | Use | Functions & Settings | Care & Maintenance | Service &...
  • Page 3: Before You Start

    Safety | Before you start | Safety These instructions are for your safety. There is a risk of electric shock Please read the following instructions and fire if cleaning is not carried carefully before proceeding with the out in accordance with these installation and use of this appliance.
  • Page 4 Safety | Safety (continued) Means for full disconnection The hood may stop working must be incorporated in the fixed during an electrostatic discharge wiring in accordance with the (e.g. lightning). This involves no local wiring installation rules risk of damage. Switch off the for your country.
  • Page 5 Safety | Safety (continued) • Do not install the appliance outdoors in • The manufacturer declines all liability for a damp place or in an area which may be personal or material damage as a result prone to water leaks such as under or near of misuse or incorrect installation of this a sink unit.
  • Page 6: Electrical Installation

    Safety | Electrical installation All installation must be carried out by a To avoid the risks that are always present competent person or qualified electrician. when you use an electrical appliance it is Before connecting the mains supply ensure important that this appliance is installed that the mains voltage corresponds to the correctly and that you read the safety voltage on the rating plate.
  • Page 7: Technical Data

    Frequency band 434 MHz Information for EU No. 66/2014 and No. 65/2014 A. Information of the cooker hood. Value Trademark Model identification WRCAN60RF WRCAN90RF Annual Energy Consumption (AEC hood) (kWh/year) Energy Efficiency class Fluid Dynamic Efficiency 28.6 Fluid Dynamic Efficiency class...
  • Page 8 Safety | Technical data Time increase factor (f ) Energy Efficiency Index (EEIhood) 58.6 Measured air flow rate at best efficiency point (QBEP) (m3/h) 425.5 Measured air pressure at best efficiency point (PBEP) (Pa) Measured electric power input at best efficiency point (WBEP) (W) Nominal power of the lighting system (WL) (W) Average illumination of the lighting system on the cooking surface (Emiddle) (lux) The measurement and calculation method of the above table was done in accordance with...
  • Page 9: Troubleshooting

    Safety | Troubleshooting Problem Possible cause Solution The appliance is not installed Take down the appliance and properly on the brackets. check it is properly fixed. Excessive vibration. The fan blade is damaged. Switch off the appliance. The fan motor is not fixed tightly. Repair to be carried out by The fan blade is jammed.
  • Page 10: Guarantee

    Object of the declaration: Object of the declaration: • Product: Canopy Extractor Hood • Product: Canopy Extractor Hood • Model: WRCAN60RF • Model: WRCAN60RF • Model: WRCAN90RF • Model: WRCAN90RF The object of the declaration described above...
  • Page 11 Guarantee | Recycling & disposal Waste electrical products (WEEE) should not be disposed of with household waste. Please recycle where facilities exist. Check with your local governmental authority, domestic waste disposal services or the retailer where the product was bought for recycling advice.
  • Page 12: What's Required For Installation

    EN Installation FR Installatio PL Montaż RO Instalare Installation | What's required for installation [04] x 1 [07] x 2 | What's in the box Only for PL Tylko dla o wentylac [01] x 1 [02] x 1 Not included [03] x 1 (PAIR) WRKITV2 Vent Pack...
  • Page 13: Installation

    EN Installation FR Installation EN Installation FR In PL Montaż RO Instalare PL Montaż RO In [07] Installation [04] | Choose a type of installation [04] x 1 [04] x 1 [07] x 2 [07] x 2 RECIRCULATION OPTION DUCTED OPTION (no extraction to the outside).
  • Page 14 Installation DUCTED OPTION (extraction to the outside) RECIRCULATION OPTION (no extraction to the outside) [04] [01] [02] x 1 [04] x 2 3.5 x 12mm WARNING: Please follow the Safety and Electrical Installation sections at the start of this manual before connecting this appliance to the mains supply.
  • Page 15 Installation >450mm ≥ 65cm ≥ 75cm >650mm Diagram shows minimum distance between hood & hob 502/802 WRCAN60 & 90RF Hood IM V2 MAY.indd 15 WRCAN60 & 90RF Hood IM V2 MAY.indd 15 25/05/2022 15:49 25/05/2022 15:49...
  • Page 16 [04] Installation [04] x 1 [07] x 2 [03] x 1 (PAIR) Only for ducted option. Uniquement pour l’option ave conduit. [03] PL Tylko dla opcji z kanałem RO Numai pentru opţiunea de m wentylacyjnym. cu tubulatură. DUCTED OPTION (extraction to the outside) RECIRCULATION OPTION (no extraction to the outside) WRKITV2...
  • Page 17 Installation WRCAN60 & 90RF Hood IM V2 MAY.indd 17 WRCAN60 & 90RF Hood IM V2 MAY.indd 17 25/05/2022 15:49 25/05/2022 15:49...
  • Page 18: Connectivity

    Connectivity | Connecting a Viceroy WRCAN60RF/90RF hood with a Viceroy hob IMPORTANT: The connectivity operation must be completed within 2 minutes of turning on the power to the hood. If this is not successful, switch off both the hood and the hob, wait for one minute and attempt the connectivity again.
  • Page 19 Connectivity | Using the connectivity function Ensure the Connectivity Indicator is lit on the hob control panel. IMPORTANT: The extraction rate of the hood will vary based upon the total power output selected on the hob, as shown in the table below.
  • Page 20: Use

    | Before you start WARNING: Please read the instructions before using the appliance. Switch on the appliance at the switched fused connection unit. The appliance is ready for use. | Functions & Settings Control panel 1. Filter Clean Warning 2. Timer 3.
  • Page 21 General Use Filter Clean Warning Displays warning of the need to replace the filter – press and hold for 3 seconds to deactivate once the filter has been cleaned/replaced. Timer Press this icon once to turn on the Timer, the current speed level of the hood will continue for 5 minutes and step down for 5 minutes at each level until finally switching off.
  • Page 22: Care & Maintenance

    Carbon filter replacement Replace every three months. 3 MONTHS Replacement Carbon filters WRFILT8 available online at viceroy.co.uk or customer helpline in Service & Spares section. WRFILT8 CARBFILT4 USER MANUAL If the motor is off, and after the fan has been...
  • Page 23 Care & Maintenance Aluminium grease filter cleaning Lamp replacement Entretien et maintenance O Îngrijire și întreținere Aluminium filters: To avoid fires, clean The LED lamps in this appliance are not thoroughly once a month. Remove both replaceable by the consumer. If a lamp grease filters as shown and soak in hot fails, please contact the Customer Helpline water and detergent for an hour.
  • Page 24: Service & Spares

    Please contact: 0333 247 1128 Monday to Friday: 9am-5pm Saturday: 9am-1pm Email enquiries: wrenservice@apelson.co.uk Dedicated spares online at: viceroy.co.uk VICEROY WRCAN60RF/WRCAN90RF V2 MAY 2022 WRCAN60 & 90RF Hood IM V2 MAY.indd 24 WRCAN60 & 90RF Hood IM V2 MAY.indd 24 25/05/2022 15:49 25/05/2022 15:49...