Contents | Before you start | Safety | Electrical installation | Technical data | Troubleshooting | Guarantee | What's required for installation | What's in the box | Installation | Connectivity | Use | Functions & Settings | Care & Maintenance | Service &...
Safety | Before you start | Safety These instructions are for your safety. There is a risk of electric shock Please read the following instructions and fire if cleaning is not carried carefully before proceeding with the out in accordance with these installation and use of this appliance.
Page 4
Safety | Safety (continued) Means for full disconnection The hood may stop working must be incorporated in the fixed during an electrostatic discharge wiring in accordance with the (e.g. lightning). This involves no local wiring installation rules risk of damage. Switch off the for your country.
Page 5
Safety | Safety (continued) • Do not install the appliance outdoors in • The manufacturer declines all liability for a damp place or in an area which may be personal or material damage as a result prone to water leaks such as under or near of misuse or incorrect installation of this a sink unit.
Safety | Electrical installation To avoid the risks that are always present when you use an electrical appliance it is important that this appliance is installed All installation must be carried out by a correctly and that you read the safety competent person or qualified electrician.
Frequency band 434 MHz Information for EU No. 66/2014 and No. 65/2014 A. Information of the cooker hood. Trademark Value Model identification WRCG60RF/60RFBK WRCG90RF/90RFBK Annual Energy Consumption (AEC hood) (kWh/year) 21.2 Energy Efficiency class Fluid Dynamic Efficiency 31.7 Fluid Dynamic Efficiency class...
Page 8
Measured electric power input at best efficiency point (WBEP) (W) Nominal power of the lighting system (WL) (W) Average illumination of the lighting system on the cooking surface WRCG60RF/60RFBK (Emiddle) (lux) WRCG90RF/90RFBK The measurement and calculation method of the above table was done in accordance with Commission Delegated Regulation (EU) No 65/2014 &...
Safety | Troubleshooting Problem Possible cause Solution The appliance is not installed Take down the appliance and properly on the brackets. check it is properly fixed. Excessive vibration. The fan blade is damaged. Switch off the appliance. The fan motor is not fixed tightly. Repair to be carried out by The fan blade is jammed.
Object of the declaration: Object of the declaration: • Product: Curved Glass Hood • Product: Curved Glass Hood • Model: WRCG60RF • Model: WRCG60RF • Model: WRCG90RF • Model: WRCG90RF • Model: WRCG60RFBK • Model: WRCG60RFBK •...
Page 11
Guarantee | Recycling & disposal Waste electrical products (WEEE) should not be disposed of with household waste. Please recycle where facilities exist. Check with your local governmental authority, domestic waste disposal services or the retailer where the product was bought for recycling advice.
Installation | What's required for installation [04] x 1 [07] x 2 | What's in the box PL Tyl [02] x 1 [03] x 1 [01] x 1 [04] x 1 [07] x 6 [05] x 1 [06] x 1 [08] x 6 4 x 32mm [09] x 6...
[07] Installation [04] | Choose a type of installation [04] x 1 [04] x 1 [07] x 2 [07] x 2 RECIRCULATION OPTION DUCTED OPTION (no extraction to the outside). (extraction to the outside) This appliance is for installation on a wall only. Only for ducted option.
Page 14
Installation | Mark the wall with the hole positions 120mm 188mm 631-906mm >590mm 180mm >650mm Diagram shows minimum distance between hood & hob Mark the wall with the hole Warning: Caution! Before drilling it is positions as shown in the diagram. extremely important to check the wall The fixings supplied are suitable for solid walls only.
Page 15
Installation [07] [08] [07] [08] [07] x 6 [08] x 2 [08] [08] 4 X 32mm [04] [04] [04] x 1 425 - 700mm [08] x 2 4 X 32mm [08] [08]...
Page 16
Installation [08] x 2 [08] 4 X 32mm [02] [02] [02] x 1 [13] [13] [10] [10] x 4 [10] [11] x 4 [12] x 4 [11] [11] [12] [12] [13] x 1 Tighten all screws (do not over tighten).
Page 17
Installation DUCTED OPTION (extraction to the outside) [09] [09] [06] [06] [06] x 1 [09] x 2 3.5 x 10mm...
Page 18
Installation DUCTED OPTION (extraction to the outside) WRKITV2 VENT PACK Vent Pack (Ø150 mm) Ø150mm DUCTED OPTION (extraction to the outside) [03] [03] x 1...
Page 19
Installation RECIRCULATION OPTION (no extraction to the outside) WRFILT4 WRFILT4 CARBFILT4 RECIRCULATION OPTION (no extraction to the outside) [03] [03] [03] x 1...
Page 20
Installation DUCTED OPTION (extraction to the outside) RECIRCULATION OPTION (no extraction to the outside) [09] x 2 3.5 x 10mm [09] [09]...
Connectivity | Connecting a Viceroy hood with a Viceroy hob IMPORTANT: The connectivity operation must be completed within 2 minutes of turning on the power to the hood. If this is not successful, switch off both the hood and the hob, wait for one minute and attempt the connectivity again.
Page 23
Connectivity | Using the connectivity function Ensure the Connectivity Indicator is lit on the hob control panel. IMPORTANT: The extraction rate of the hood will vary based upon the total power output selected on the hob, as shown in the table below.
| Before you start WARNING: Read the instructions before using the appliance. Switch on the appliance at the switched fused connection unit. The appliance is ready for use. | Functions & Settings Four-button panel To obtain the best results from your cooker hood it is recommended that you leave it switched on for up to 15 minutes after you have finished cooking.
Page 25
General Use Setting the Timer • When the fan motor is on and the Light On/Off Timer icon is pressed, it will be blue and the current speed in the • Use this control to switch the light on display will start to flash. independently of the fan motor, it will be lit blue in this mode.
In the event of a fault, contact customer services. Carbon filter replacement Replace every three months. 3 MONTHS Replacement Carbon filters WRFILT4 available viceroy.co.uk online at or customer helpline in Service & Spares section. WRFILT4 CARBFILT4...
Page 27
Entretien et maintenance Îngrijire și întreținere Care & Maintenance | Looking after your appliance efore replacing the carbon filters. Aluminium grease filter cleaning Lamp replacement Aluminium filters: To avoid fires, clean The LED lamps in this appliance are not thoroughly once a month. Remove both replaceable by the consumer.
| After sales & service support For after sales, service enquiries & spares support Please contact: 0333 247 1128 Monday to Friday: 9am-5pm Saturday: 9am-1pm Email enquiries: wrenservice@apelson.co.uk Dedicated spares online at: viceroy.co.uk VICEROY WRCG60RF/90RF & WRCG60RFBK/90RFBK V4 MAY 2022...
Need help?
Do you have a question about the WRCG60RF and is the answer not in the manual?
Questions and answers
I went to switch on the extractor fan and all the lights on the appliance started flashing and beeping non stop.