NOTICE
You can use this command to check whether the communication between PC and code reader
is functional.
Ä If you do not receive an acknowledgment, please check the interface connections or the pro-
tocol.
Software reset
Command
Description
Parameter
Acknowledgment
Auto-setup
Command
Description
Parameter
Acknowledgment
Leuze electronic
'H'
Carries out a software reset. The device is restarted and reinitialized, leaving it in the
same state as when the operating voltage is switched on.
None
'S' (start signal)
'CA'
Activates the Auto setup function:
• Determine optimum illumination settings.
• Decode present code.
• Permanently store found code types and number of digits in the decoder table.
This is performed if a configuration code is present!
'+'
Activates Auto setup
'CS=x'
x
Status
'00'
'01'
'02'
Valid 'CA' command
Invalid command
'Auto setup' could not be activated
DCR 202i