Altronix OA2 Series Installation Manual
Altronix OA2 Series Installation Manual

Altronix OA2 Series Installation Manual

Occupancy alert system

Advertisement

Altronix OA2B / OA2 / OA2X is designed to alert management when unauthorized loitering occurs in up to two
(2) secure rooms. OA2B / OA2 / OA2X has built-in LINQ Technology to remotely monitor and control the unit.
Input Power Options:
• OA2X - 115VAC, 60Hz.
(with line cord and transformer)
OA2B and OA2 - 24VAC/50VA Plug-in transformer.
• Trigger
- Two (2) Door Sensor/Trigger inputs.
- Two (2) Strobe "Steady" Trigger Inputs.
- Two (2) Strobe "Flash" Trigger Inputs.
- Two (2) "Panic/Emergency" Trigger Inputs.
Output Options:
• 12VDC/2.5A, 24VDC/1.25A, (30W).
• Two (2) Strobe Switched Power Outputs.
• Four (4) Aux. Power Outputs.
Timer:
• Alphanumeric LCD display simplifies programming.
• EE Prom memory protects against loss
of programming due to power failure.
• Momentary and/or Latching Events.
Battery Backup:
• Sealed lead acid or gel type.
• Failover - Upon AC loss, instantaneous.
LINQ Technology:
• Remote network management allows for
device reset and monitoring.
• Provides local and/or remote access to critical
information via LAN/WAN.
• Event log tracks history.
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all
local codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Mount the unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes
in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the
enclosure's upper keyholes over the two upper screws; level and secure. Mark the position of the lower two
holes. Remove the enclosure. Drill the lower holes and install two fasteners. Place the enclosure's upper
keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws
(Enclosure Dimensions, pg. 4). Secure enclosure to earth ground (Fig 1, pg. 2).
2. Connect the Brown wire from the strobe to OA2B terminals marked [DOOR 1 LED +].
3. Connect the Green wire from the strobe trigger to OA2B terminals marked [DOOR 1 Strobe Steady].
Connect the Yellow wire from the strobe trigger to OA2B terminals marked [DOOR 2 Strobe Steady].
4. Connect the positive and negative terminals on the Optical Latch Sensor for Door 1 to the OA2B terminals
marked [– AUX1 +]. Connect the White and Blue wires from the Optical Latch Sensor to the OA2B terminals
marked [DOOR 1 C, TRIG, NO].
5. Connect the positive and negative terminals on the Optical Latch Sensor for Door 2 to the OA2B terminals
marked [– AUX2 +]. Connect the White and Blue wires from the Optical Latch Sensor to the OA2B terminals
marked [DOOR 2 C, TRIG, NO].
6. Plug in 3-wire line cord). Keep power-limited wiring separate from non-power-limited wiring.
Minimum 0.25" spacing must be provided. Use separate knockouts.
OA2 Series
Occupancy Alert System
Installation Guide
Overview:
Specifications:

Installation Instructions:

Visual Indicators:
• AC Power (Green) - Input voltage is present.
DC Output (Green) - 12VDC
DC Output (Orange) - 24VDC
Trigger - Active.
Physical and Environmental:
• OA2B Board Dimensions (L x W x H approx.):
6.125" x 3.875" x 1.5"
(155.6mm x 98.4mm x 38.1mm)
• OA2 and OA2X Enclosure Dimensions
(H x W x D approx.):
8.5" x 7.5" x 3.5"
(215.9mm x 190.5mm x 88.9mm).
- 1/2" and 3/4" combination knockouts.
- OA2 - Enclosure accommodates up to
two (2) 12VDC/4AH batteries.
• Temperature:
Operating:
Storage:
• Relative Humidity: 85% +/– 5%.
Models:
• OA2B - Board only
• OA2 - Board mounted in enclosure
• OA2X - Board mounted in enclosure
with transformer and line cord included.
0ºC to 49ºC (32ºF to 120ºF).
– 20ºC to 70ºC (– 4ºF to 158ºF).

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OA2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Altronix OA2 Series

  • Page 1 Installation Guide Overview: Altronix OA2B / OA2 / OA2X is designed to alert management when unauthorized loitering occurs in up to two (2) secure rooms. OA2B / OA2 / OA2X has built-in LINQ Technology to remotely monitor and control the unit.
  • Page 2 INPUT DOOR 2 ENTER DOWN DC OUPUT GREEN = 12V ORANGE = 24V TRIG PANIC STROBE1 – AUX1 + – AUX2 + – AUX3 + – AUX4 + STDY FLASH + LED - - 2 - OA2 Series Installation Guide...
  • Page 3 – AUX1 + – AUX2 + – AUX3 + – AUX4 + STDY FLASH + LED - Door 1 Optical Latch Sensor Optical Latch Sensor Control Module Door 2 Optical Latch Sensor Strobe OA2 Series Installation Guide - 3 -...
  • Page 4 5.25” (133.35mm) 1” 1” (25.4mm) (25.4mm) Altronix is not responsible for any typographical errors. –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IIOA2 Series Rev. 030421...