SKU
Description
Band Removal tool
WGB-REMOVE-1000
Starter Kit for Wearables
WGB-TGSTART-1000
Wearable Specifications
LF Frequency
125 kHz
BLE Frequency
2400-2483.5 MHz
Battery Power
3 VDC
Battery Life
WGB-TAG-2000-1Y: 90 Days
WGB-TAG-2000-1Y: 1 Year
WGB-TAG-2000-3Y: 3 Years
Operating
32° to 122°F (0° to +50°C)
Temperature
Humidity
0-95% RH @ 70°F (21°C), non-
condensing
IP Rating
IP67
UL294
ACC Accessory, TYPE: S, 17XS
Dimensions
2.0 x 1.1 x 0.51" (50.6 x 28 x
13 mm) without band
Weight
0.92 oz. (26.0 g) with band
The Wearable is intended for indoor use only.
STANLEY Healthcare reserves the right to
change specifications without notice.
FCC
Suppliers Declaration of Conformity
47 CFR § 2.1077 Compliance Information
Unique Identifiers:
WGB-TAG-2000-90D
WGB-TAG-2000-1Y
WGB-TAG-2000-3Y
Responsible Party: Stanley Security
Solutions Inc., STANLEY Healthcare Div.,
4600 Vine Street, Lincoln, NE 68503
Telephone: (888) 622-6992
FCC Compliance Statement: 47 CFR Part
15, Class A Digital Device
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following
two conditions: (1) this device may not cause
harmful interference, and (2) this device must
accept any interference received, including
any interference that may cause undesired
operation.
Changes or modifications not expressly
approved by the party responsible for com-
pliance could void the user's authority to
operate the equipment.
Canada—Innovation, Science, and Economic
Development Canada;
This device contains license-exempt
transmitter(s)/receiver(s) that comply with
Innovation, Science, and Economic Devel-
opment Canada's license-exempt RSS(s).
Operation is subject to the following two
conditions:
(1) This device may not cause interference.
(2) This device must accept any intefrerence,
including interference tht may cause unde-
sired operation of the device.
Limitation of Liability
This Product has been designed for use to
reduce the risk of resident wandering through
remote detection.
The range, accuracy, function and performance
of this Product may vary from the published
specifications due to many factors, includ-
ing, without limitation, site impairments from
structural effects, metal objects in the vicinity,
placement of the receiver and transmitter, inter-
ference from other electrical devices, atmo-
spheric effects, installation, and maintenance.
There may be other factors, which also affect
performance of this Product.
STANLEY Healthcare does not guarantee
that this Product will detect 100% of resident
wanderings. STANLEY Healthcare does not
guarantee that this Product will not return false
reports of resident wandering.
Weekly testing and maintenance of this
Product, as described in the Product docu-
mentation, is essential to verify the system is
operating correctly and to ensure that the prob-
ability of detecting an alarm and/or locating the
transmitter are maximized.
The failure to undertake regular testing and
maintenance will increase the risk of system
failure and failure to detect resident wander-
ing. The failure to undertake regular testing
and maintenance will increase the risk of false
reports of resident wandering.
STANLEY Healthcare hereby disclaims all war-
ranties, express or implied, arising out of or in
connection with any of its Products or the use or
performance thereof, including but not limited
to, where allowable by law, all other implied
warranties or conditions of merchantable qual-
ity and fitness for a particular purpose and those
arising by statute or otherwise in law or from a
course of dealing or usage of trade.
STANLEY Healthcare's liability to you or
anyone claiming through or on behalf of you
with respect to any claim or loss arising out of
the use or misuse of STANLEY Healthcare's
Product, defective products or materials,
improper installation or maintenance of
STANLEY Healthcare's Product or products or
the system in which they are incorporated, or
alleged to have resulted from an act or omis-
sion of STANLEY Healthcare or any person,
negligent or otherwise, shall be limited to:
A) the repair or replacement of defective Product
or materials supplied by STANLEY Healthcare
during the warranty period as set out in the
Product documentation; or, at the option of
STANLEY Healthcare,
B) a refund of the purchase price of the Product
supplied by STANLEY Healthcare.
In no event shall STANLEY Healthcare be
liable for general, specific, indirect, conse-
quential, incidental, exemplary or punitive
damages or any losses or expenses suf-
fered by you or anyone else, whether or not
STANLEY Healthcare, or its employees, offi-
cers, agents, resellers or installers has been
informed of the risk of such loss or expense
and whether or not such losses or expenses
were foreseeable.