LG OLED48C3 Series Service Manual page 62

Table of Contents

Advertisement

Standard Repair Process Detail Technical Manual
symptom
Content
SET Model
OLED48C3
EAY65768829, LGP48C3-23OP
Power Check Sequence
1. AC input Check : 100~240Vac
2. PWR-ON Check : P201
- SET On : above 3V
- SET St-by : 0V
3. 12V Level Check : P201
- SET On : 12V
- SET St-by : 7.8V (swing between 7V to 10V)
4. DRV_ON Check : P201
- SET On : above 2.5V
- SET St-by : 0V
5. T-CON 22V Check : P251
- SET On : above 22V
- SET St-by : 0V
6. T-CON 12V Check : P202
- SET On : above 12V
- SET St-by : 0V
All condition meets, Power Board OK.
Error
B. Power error _No power
Check power input voltage and ST-BY 7.8V
Power P/N, Name
Established
date
Revised
date
AC INPUT
A9
DC 12VM Line Check (ST-
BY : 7.8V, Normal : 12V)
Copyright © 2023 LG Electronics. Inc. All rights reserved.
Only for training and service purposes.
A9
P201
P252
P251

Hide quick links: