Bair Hugger 750 Operator's Manual

Bair Hugger 750 Operator's Manual

Temperature management unit
Hide thumbs Also See for 750:

Advertisement

Quick Links

Check the Bair Hugger therapy website to ensure you have the most recent version of this document.
Bair Hugger
Betriebshandbuch für Bair Hugger*
Temperaturmanagement-Gerät Modell 750
Manuel de l'utilisateur pour appareil de gestion
de la température Bair Hugger* Modèle 750
Manuale per l'operatore dell'unità per la gestione
della temperatura Bair Hugger* Modello 750
Manual del operario de la unidad de control
de temperatura Bair Hugger* Modelo 750
Manual do utilizador da unidade de gestão
de temperatura Bair Hugger* Modelo 750
Gebruiksaanwijzing voor de Bair Hugger*
temperatuurregelunit Model 750
Brugsanvisning til Bair Hugger* Model 750
temperaturreguleringsenhed
Användarhandbok för Bair Hugger*
temperaturstyrenhet Modell 750
To t a l Te m p e r a t u r e M a n a g e m e n t S y s t e m
*
Model 750
Bair Hugger
Temperature Management Unit
Model 750
Operator's Manual
www.bairhugger.com
*
Brukerhåndbok for Bair Hugger*
temperaturbehandlingsenhet Modell 750
Bair Hugger* -lämpötilansäätölaitteen –
Malli 750 käyttöopas
Bair Hugger* ªÔÓÙ¤ÏÔ 750 ªÔÓ¿‰· ¢È·¯Â›ÚÈÛ˘
£ÂÚÌÔÎÚ·Û›·˜-∂Á¯ÂÈÚ›‰ÈÔ ÃÚ‹ÛÙË
Bair Hugger ベアーハガーモデル750体温管理装置
Instrukcja Obsługi Dmuchawy Bair Hugger* Model 750 -
urządzenia do aktywnego przeciwdziałania hipotermii
Bair Hugger* 750 sz. Modell testmelegítő berendezés
Jednotka regulace teploty Bair Hugger* typ 750
„Bair Hugger*" Modelis 750 Temperatūros reguliavimo
prietaisas
„Bair Hugger" 750 modelio temperatūros valdymo įtaiso
naudojimo instrukcija
reorder #200742G

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 750 and is the answer not in the manual?

Questions and answers

Summary of Contents for Bair Hugger 750

  • Page 1 Check the Bair Hugger therapy website to ensure you have the most recent version of this document. www.bairhugger.com reorder #200742G Bair Hugger Model 750 Bair Hugger Temperature Management Unit Model 750 Operator’s Manual Betriebshandbuch für Bair Hugger* Brukerhåndbok for Bair Hugger* Temperaturmanagement-Gerät Modell 750...
  • Page 3 Bair Hugger Model 750 Bair Hugger Temperature Management Unit Model 750 Operator’s Manual English Deutsch Français Italiano Español Português Nederlands Dansk Svenska Norsk Sumoi Ελληνικά 日本語 Polski Magyar Česky Lietuvių Kalba...
  • Page 5 English...
  • Page 7 Bair Hugger Model 750 Bair Hugger Model 750 Temperature Management Unit Operator’s Manual Table of Contents Introduction                                                                        ...
  • Page 9 Bair Hugger forced-air blankets, Bair Paws* patient warming gowns and the 241* blood/fluid warming set You can use the Model 750 temperature management unit in all clinical settings including the operating room to provide patient temperature management...
  • Page 10 Resuable blankets made from woven fabric, or blankets without discrete, visible holes, can cause the safety system of this unit to fail, which may result in serious thermal injury This warming unit has been designed to operate safety ONLY with Bair Hugger blankets and Bair Paws gowns...
  • Page 11: Proper Use And Maintenance

    If service does not require the manufacturer’s attention, the Model 750 Service Manual provides the technical information needed to service the unit, or Arizant Healthcare Inc will provide that information on request Perform all repairs and...
  • Page 12: Overview And Operation

    Performs all self-test functions • Illuminates indicator lights and all pixels in the alphanumeric display momentarily • Displays the text “BH 750” and the software revision level in the alphanumeric display • Sounds the alarm (three low-level clicks) • Enters the Standby mode If the temperature management unit loses power for less than 1 second, the unit’s software...
  • Page 13: Overview Of Control Panel

    Bair Hugger Model 750 Bair Hugger Model 750 Temperature Management Unit Operator’s Manual Overview of Control Panel Figure C Model 750 temperature management unit control panel alphanumeric display The alphanumeric display shows the temperature at the blanket end of the temperature...
  • Page 14 Bair Hugger Model 750 Bair Hugger Model 750 Temperature Management Unit Operator’s Manual standby When the unit is in Low (32°C), Med (38°C), High (43°C), or Ambient mode, press the Standby button to place the unit in Standby mode When you select the Standby mode, the following events occur: •...
  • Page 15 Failure to do so may result in IV pole tipping, catheter site trauma, and patient injury method To mount the Model 750 temperature management unit to an IV pole, simply turn the clamp handle clockwise to tighten the clamp on the IV pole and counterclockwise to...
  • Page 16 If the Model 750 temperature management unit is not mounted on an IV pole or Bair Hugger rolling stand, place the unit on a flat, hard, dry surface, such as a table, before beginning temperature management therapy Do not place the temperature...
  • Page 17 Contact a qualified service technician What to Do in Case of a Fault Condition The Model 750 temperature management unit’s software recognizes several non-hazardous conditions and reports those conditions as faults When a system fault occurs, the software stores the fault code in memory, the amber Fault indicator light flashes, and an alarm...
  • Page 18: General Maintenance

    Bair Hugger Model 750 Bair Hugger Model 750 Temperature Management Unit Operator’s Manual General Maintenance Cleaning the Cabinet and Hose warning Do not immerse the cabinet or hose while cleaning Moisture will damage the components, and thermal injury may result precautions •...
  • Page 19: Technical Support And Customer Service

    0800-877-088 (Toll-free in Switzerland) When You Call for Technical Support We will need to know the serial number of your Bair Hugger temperature management unit when you call us The serial number label is located on the back or side of the...
  • Page 20: Specifications

    Bair Hugger Model 750 Bair Hugger Model 750 Temperature Management Unit Operator’s Manual Specifications Physical Characteristics dimensions 125" high x 135" deep x 10" wide 315 cm high x 34 cm deep x 25 cm wide weight 163 lb (74 kg)
  • Page 21: Leakage Current

    Bair Hugger Model 750 Bair Hugger Model 750 Temperature Management Unit Operator’s Manual Electrical Characteristics heating element 1400 W Resistive leakage current Meets UL 60601-1 and IEC 60601-1 requirements blower motor Operating speed: approximately 4,000 rpm Airflow: up to 48 cfm or 23 L/s...
  • Page 22: Definition Of Symbols

    Bair Hugger Model 750 Bair Hugger Model 750 Temperature Management Unit Operator’s Manual Definition of Symbols The following symbols may appear on the product’s labeling or exterior packaging. ON/STANDBY ON (used on isolation switch) OFF (used on isolation switch) ON/OFF push button switch...

Table of Contents